Strength of welded headed studs in ribbed metal deck on composite joists

Standards for stud strength in composite joists are presently not available. Existing standards for composite design are targeted for composite beam design while design of a composite joist requires more emphasis on stud strength to fully develop the joist bottom chord. Stud placement in the deck fl...

Full description

Bibliographic Details
Main Author: Sublett, Charles Nelson
Other Authors: Civil Engineering
Format: Others
Language:en
Published: Virginia Tech 2014
Subjects:
Online Access:http://hdl.handle.net/10919/45303
http://scholar.lib.vt.edu/theses/available/etd-10242009-020240/
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-45303
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-453032021-05-15T05:26:42Z Strength of welded headed studs in ribbed metal deck on composite joists Sublett, Charles Nelson Civil Engineering LD5655.V855 1991.S926 Steel joists -- Research Standards for stud strength in composite joists are presently not available. Existing standards for composite design are targeted for composite beam design while design of a composite joist requires more emphasis on stud strength to fully develop the joist bottom chord. Stud placement in the deck flute is investigated. Thirty-six push-off specimens were tested with three different deck geometries. A normal load apparatus models gravity loading in an attempt to represent full-scale joist behavior during the push-off test procedure. The results illustrate that the current AISC specifications (ASD 1989; LRFD 1986) do not accurately predict stud strength for studs placed in ribbed metal deck when the deck is perpendicular to the shear loading. Master of Science 2014-03-14T21:48:10Z 2014-03-14T21:48:10Z 1991 2009-10-24 2009-10-24 2009-10-24 Thesis Text etd-10242009-020240 http://hdl.handle.net/10919/45303 http://scholar.lib.vt.edu/theses/available/etd-10242009-020240/ en OCLC# 24111850 LD5655.V855_1991.S926.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ x, 258 leaves BTD application/pdf application/pdf Virginia Tech
collection NDLTD
language en
format Others
sources NDLTD
topic LD5655.V855 1991.S926
Steel joists -- Research
spellingShingle LD5655.V855 1991.S926
Steel joists -- Research
Sublett, Charles Nelson
Strength of welded headed studs in ribbed metal deck on composite joists
description Standards for stud strength in composite joists are presently not available. Existing standards for composite design are targeted for composite beam design while design of a composite joist requires more emphasis on stud strength to fully develop the joist bottom chord. Stud placement in the deck flute is investigated. Thirty-six push-off specimens were tested with three different deck geometries. A normal load apparatus models gravity loading in an attempt to represent full-scale joist behavior during the push-off test procedure. The results illustrate that the current AISC specifications (ASD 1989; LRFD 1986) do not accurately predict stud strength for studs placed in ribbed metal deck when the deck is perpendicular to the shear loading. === Master of Science
author2 Civil Engineering
author_facet Civil Engineering
Sublett, Charles Nelson
author Sublett, Charles Nelson
author_sort Sublett, Charles Nelson
title Strength of welded headed studs in ribbed metal deck on composite joists
title_short Strength of welded headed studs in ribbed metal deck on composite joists
title_full Strength of welded headed studs in ribbed metal deck on composite joists
title_fullStr Strength of welded headed studs in ribbed metal deck on composite joists
title_full_unstemmed Strength of welded headed studs in ribbed metal deck on composite joists
title_sort strength of welded headed studs in ribbed metal deck on composite joists
publisher Virginia Tech
publishDate 2014
url http://hdl.handle.net/10919/45303
http://scholar.lib.vt.edu/theses/available/etd-10242009-020240/
work_keys_str_mv AT sublettcharlesnelson strengthofweldedheadedstudsinribbedmetaldeckoncompositejoists
_version_ 1719404649889398784