The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters

The removal mechanisms of soluble manganese [Mn (1l)] through mixed-media filters were investigated. Experimentation was directed toward the continuous supply of an oxidant during column filter studies. Free chlorine (HOCl, OC1â ) was chosen to increase soluble manganese removal efficiency because...

Full description

Bibliographic Details
Main Author: Occiano, Suzanne
Other Authors: Environmental Sciences and Engineering
Format: Others
Published: Virginia Tech 2014
Subjects:
Online Access:http://hdl.handle.net/10919/44082
http://scholar.lib.vt.edu/theses/available/etd-08012012-040338/
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-44082
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-440822021-05-05T05:40:31Z The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters Occiano, Suzanne Environmental Sciences and Engineering Knocke, William R. Boardman, Gregory D. Hoehn, Robert C. LD5655.V855 1988.O224 Water -- Purification -- Filtration Water -- Purification -- Manganese removal The removal mechanisms of soluble manganese [Mn (1l)] through mixed-media filters were investigated. Experimentation was directed toward the continuous supply of an oxidant during column filter studies. Free chlorine (HOCl, OC1â ) was chosen to increase soluble manganese removal efficiency because chlorine is readily available and inexpensive. Filter media from four different water treatment plants were used in this study. Continuous-flow filter columns were operated in the presence and absence of 2.0 milligrams per Liter (mg/ L) free chlorine. Maintaining constant influent manganese concentrations of 1.0 mg/L and flow rates of 2.5 gallons per minute per foot squared (gpm/ft2), the operational pH values of 6-6.2, 7.8 and 8.8 were investigated. Results indicate that a continuous feed of free chlorine (2 mg/L) applied to the filter columns could increase manganese (II) removal efficiency. However, the amount and oxidation state of the MnOx(S) surface coating initially on the media and the influent pH had major influences upon the uptake of soluble manganese. From numerous Mn (II) uptake studies with different media and varying pH conditions, oxide-coated filter media continuously regenerated with free chlorine could result in increased soluble manganese removal through adsorption upon the MnOx(s) surface coating and subsequent oxidation directly on the media surface. The relationships of manganese removal and chlorine consumed were also explored. To further investigate the mechanisms of free chlorine oxidation for the removal of reduced manganese, pH 5.0 backtitrations were conducted following exhaustion of the filter media. The exposure of such low pll conditions to columns operated in the presence and absence of HOCI would ascertain if oxidation of the adsorbed Mn2+ was always occurring, regardless of an oxidant feed. Results indicated that in the absence of HOCI, the mechanisms for manganese removal on oxide-coated filter media were adsorption only. With the additional of HOCI, the adsorbed Mn2+ is oxidized directly on the surface of the media, thereby, continuously regenerating the surface oxide coating. Additional work was begun to ascertain if free chlorine could be used as a viable alternative to potassium permanganate (KMnO4) regeneration of oxide-coated filter media. Preliminary findings indicate from column cycling experiments that free chlorine could be used to regenerate oxide-coated filter media prior to backwashing. Master of Science 2014-03-14T21:41:57Z 2014-03-14T21:41:57Z 1988-12-05 2012-08-01 2012-08-01 2012-08-01 Thesis Text etd-08012012-040338 http://hdl.handle.net/10919/44082 http://scholar.lib.vt.edu/theses/available/etd-08012012-040338/ OCLC# 19608567 LD5655.V855_1988.O224.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ xi, 98 leaves BTD application/pdf application/pdf Virginia Tech
collection NDLTD
format Others
sources NDLTD
topic LD5655.V855 1988.O224
Water -- Purification -- Filtration
Water -- Purification -- Manganese removal
spellingShingle LD5655.V855 1988.O224
Water -- Purification -- Filtration
Water -- Purification -- Manganese removal
Occiano, Suzanne
The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
description The removal mechanisms of soluble manganese [Mn (1l)] through mixed-media filters were investigated. Experimentation was directed toward the continuous supply of an oxidant during column filter studies. Free chlorine (HOCl, OC1â ) was chosen to increase soluble manganese removal efficiency because chlorine is readily available and inexpensive. Filter media from four different water treatment plants were used in this study. Continuous-flow filter columns were operated in the presence and absence of 2.0 milligrams per Liter (mg/ L) free chlorine. Maintaining constant influent manganese concentrations of 1.0 mg/L and flow rates of 2.5 gallons per minute per foot squared (gpm/ft2), the operational pH values of 6-6.2, 7.8 and 8.8 were investigated. Results indicate that a continuous feed of free chlorine (2 mg/L) applied to the filter columns could increase manganese (II) removal efficiency. However, the amount and oxidation state of the MnOx(S) surface coating initially on the media and the influent pH had major influences upon the uptake of soluble manganese. From numerous Mn (II) uptake studies with different media and varying pH conditions, oxide-coated filter media continuously regenerated with free chlorine could result in increased soluble manganese removal through adsorption upon the MnOx(s) surface coating and subsequent oxidation directly on the media surface. The relationships of manganese removal and chlorine consumed were also explored. To further investigate the mechanisms of free chlorine oxidation for the removal of reduced manganese, pH 5.0 backtitrations were conducted following exhaustion of the filter media. The exposure of such low pll conditions to columns operated in the presence and absence of HOCI would ascertain if oxidation of the adsorbed Mn2+ was always occurring, regardless of an oxidant feed. Results indicated that in the absence of HOCI, the mechanisms for manganese removal on oxide-coated filter media were adsorption only. With the additional of HOCI, the adsorbed Mn2+ is oxidized directly on the surface of the media, thereby, continuously regenerating the surface oxide coating. Additional work was begun to ascertain if free chlorine could be used as a viable alternative to potassium permanganate (KMnO4) regeneration of oxide-coated filter media. Preliminary findings indicate from column cycling experiments that free chlorine could be used to regenerate oxide-coated filter media prior to backwashing. === Master of Science
author2 Environmental Sciences and Engineering
author_facet Environmental Sciences and Engineering
Occiano, Suzanne
author Occiano, Suzanne
author_sort Occiano, Suzanne
title The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
title_short The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
title_full The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
title_fullStr The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
title_full_unstemmed The mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
title_sort mechanism for free chlorine oxidation of reduced manganese in mixed-media filters
publisher Virginia Tech
publishDate 2014
url http://hdl.handle.net/10919/44082
http://scholar.lib.vt.edu/theses/available/etd-08012012-040338/
work_keys_str_mv AT occianosuzanne themechanismforfreechlorineoxidationofreducedmanganeseinmixedmediafilters
AT occianosuzanne mechanismforfreechlorineoxidationofreducedmanganeseinmixedmediafilters
_version_ 1719402682254360576