Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers

The discovery of cancer biomarkers is crucial in the clinical setting to facilitate early diagnosis and treatment, thereby increasing survival rates. Proteomic technologies with mass spectrometry detection (MS) have the potential to affect the entire spectrum of cancer research by identifying these...

Full description

Bibliographic Details
Main Author: Sarvaiya, Hetal Abhijeet
Other Authors: Biomedical Engineering and Sciences
Format: Others
Published: Virginia Tech 2014
Subjects:
Online Access:http://hdl.handle.net/10919/42169
http://scholar.lib.vt.edu/theses/available/etd-04212006-161144/
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-42169
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-421692020-09-29T05:42:44Z Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers Sarvaiya, Hetal Abhijeet Biomedical Engineering and Sciences Lazar, Iuliana M. Love, Brian J. Lee, Yong Woo Mass spectrometry Cancer Biomarkers Proteomics MCF7 Microfluidics The discovery of cancer biomarkers is crucial in the clinical setting to facilitate early diagnosis and treatment, thereby increasing survival rates. Proteomic technologies with mass spectrometry detection (MS) have the potential to affect the entire spectrum of cancer research by identifying these biomarkers. Simultaneously, microfabricated devices have evolved into ideal analysis platforms for minute amounts of sample, with promising applications for proteomic investigations and future biomarker screening. This thesis reports on the analysis of the proteomic constituents of the MCF7 breast cancer cell line using a shotgun 2-D strong cationic exchange/reversed phase liquid chromatography electrospray ionization tandem mass spectrometry (SCX/RP-LC-ESI-MS/MS) protocol. A series of optimization strategies were performed to improve the LC-MS experimental set-up, sample preparation, data acquisition and database searching parameters, and to enable the detection and confident identification of a large number of proteins. Over ~4,500 proteins were identified using conventional filtering parameters, and >2000 proteins using a combination of filters and p-value sorting. Of these, ~1,950 proteins had p<0.001 (~90%) and more than half were identified by &#8805; 2 unique peptides. About 220 proteins were functionally involved in cancer related cellular processes, and over 100 proteins were previously described in the literature as potential cancer markers. Biomarkers such as PCNA, cathepsin D, E-cadherin, 14-3-3-sigma, antigen Ki-67, TP53RK, and calreticulin were identified. These data were generated by subjecting to mass spectrometric analysis ~42 µg of protein digest, analyzing 16 SCX peptide fractions, and interpreting ~55,000 MS2 spectra. Total MS time required for analysis was 40 h. Selective SCX fractions were also analyzed by using a microfluidic LC platform. The performance of the microchip LC was comparable to that obtained with bench-top instrumentation when similar experimental conditions were used. The identification of 5 cancer biomarkers was enabled by using the microchip LC platform. Furthermore, this device was also capable to analyze phosphopeptides. Master of Science 2014-03-14T21:34:16Z 2014-03-14T21:34:16Z 2006-04-18 2006-04-21 2008-05-24 2006-05-24 Thesis etd-04212006-161144 http://hdl.handle.net/10919/42169 http://scholar.lib.vt.edu/theses/available/etd-04212006-161144/ Hetal_Thesis_051906.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ application/pdf Virginia Tech
collection NDLTD
format Others
sources NDLTD
topic Mass spectrometry
Cancer
Biomarkers
Proteomics
MCF7
Microfluidics
spellingShingle Mass spectrometry
Cancer
Biomarkers
Proteomics
MCF7
Microfluidics
Sarvaiya, Hetal Abhijeet
Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers
description The discovery of cancer biomarkers is crucial in the clinical setting to facilitate early diagnosis and treatment, thereby increasing survival rates. Proteomic technologies with mass spectrometry detection (MS) have the potential to affect the entire spectrum of cancer research by identifying these biomarkers. Simultaneously, microfabricated devices have evolved into ideal analysis platforms for minute amounts of sample, with promising applications for proteomic investigations and future biomarker screening. This thesis reports on the analysis of the proteomic constituents of the MCF7 breast cancer cell line using a shotgun 2-D strong cationic exchange/reversed phase liquid chromatography electrospray ionization tandem mass spectrometry (SCX/RP-LC-ESI-MS/MS) protocol. A series of optimization strategies were performed to improve the LC-MS experimental set-up, sample preparation, data acquisition and database searching parameters, and to enable the detection and confident identification of a large number of proteins. Over ~4,500 proteins were identified using conventional filtering parameters, and >2000 proteins using a combination of filters and p-value sorting. Of these, ~1,950 proteins had p<0.001 (~90%) and more than half were identified by &#8805; 2 unique peptides. About 220 proteins were functionally involved in cancer related cellular processes, and over 100 proteins were previously described in the literature as potential cancer markers. Biomarkers such as PCNA, cathepsin D, E-cadherin, 14-3-3-sigma, antigen Ki-67, TP53RK, and calreticulin were identified. These data were generated by subjecting to mass spectrometric analysis ~42 µg of protein digest, analyzing 16 SCX peptide fractions, and interpreting ~55,000 MS2 spectra. Total MS time required for analysis was 40 h. Selective SCX fractions were also analyzed by using a microfluidic LC platform. The performance of the microchip LC was comparable to that obtained with bench-top instrumentation when similar experimental conditions were used. The identification of 5 cancer biomarkers was enabled by using the microchip LC platform. Furthermore, this device was also capable to analyze phosphopeptides. === Master of Science
author2 Biomedical Engineering and Sciences
author_facet Biomedical Engineering and Sciences
Sarvaiya, Hetal Abhijeet
author Sarvaiya, Hetal Abhijeet
author_sort Sarvaiya, Hetal Abhijeet
title Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers
title_short Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers
title_full Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers
title_fullStr Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers
title_full_unstemmed Mass Spectrometric Characterization of the MCF7 Cancer Cell Line: Proteome Profile and Cancer Biomarkers
title_sort mass spectrometric characterization of the mcf7 cancer cell line: proteome profile and cancer biomarkers
publisher Virginia Tech
publishDate 2014
url http://hdl.handle.net/10919/42169
http://scholar.lib.vt.edu/theses/available/etd-04212006-161144/
work_keys_str_mv AT sarvaiyahetalabhijeet massspectrometriccharacterizationofthemcf7cancercelllineproteomeprofileandcancerbiomarkers
_version_ 1719345277382426624