A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns
Inspired by the need to study injectant flow patterns near the test surface, a supersonic free-jet facility was designed and constructed. This facility provides a Mach 1.95 flow over a test section area of 6.35 cm by 5.08 cm. The facility was thoroughly tested and proved that it is durable, versatil...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | en |
Published: |
Virginia Tech
2014
|
Subjects: | |
Online Access: | http://hdl.handle.net/10919/41997 http://scholar.lib.vt.edu/theses/available/etd-04082009-040935/ |
id |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-41997 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-419972021-08-21T05:30:45Z A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns Mills, John Richard Mechanical Engineering LD5655.V855 1991.M573 Flow injection analysis Jets -- Fluid dynamics Inspired by the need to study injectant flow patterns near the test surface, a supersonic free-jet facility was designed and constructed. This facility provides a Mach 1.95 flow over a test section area of 6.35 cm by 5.08 cm. The facility was thoroughly tested and proved that it is durable, versatile, and capable of providing repeatable test conditions. When compared to the main supersonic tunnel at VPI & SU, the free-jet facility has many advantages, including greater optical and spatial access, longer available test durations, and less time needed between tests for the storage tanks to be refilled. As a part of the project, several diagnostic techniques were evaluated in the facility. Normal, sonic injection of helium through a circular injector was studied as a way to evaluate nanoshadowgraph photography, oil flow photography, and infrared imaging as qualitative flow visualization methods. Quantitative measurements of the local helium concentration within the boundary layer were taken to evaluate the effectiveness of an existing hot-film concentration probe. The tests showed that oil flow visualization is a very effective technique in the free-jet facility, producing clear photographs that could be directly scaled. Nanoshadowgraph photography also produced clear photographs of the flow field, although this method was more difficult to implement in the free-jet facility than in the main supersonic tunnel. Finally, infrared imaging, which was not possible in the main supersonic tunnel without major hardware reconfigurations, showed great promise as a method for studying normal injection. Although the tests revealed no conclusive information about injectant flow patterns in the boundary layer, a heat transfer analysis showed that it may be possible in future studies to use this technique as a way to quantitatively measure local helium concentration at the surface. Helium concentration was measured for test cases with both air and helium injection. The measurements were taken at two axial locations with the probe positioned at a distance of 0.1 injector diameters above the test surface. The air injection tests showed helium concentration levels up to 30 percent mole fraction, which is erroneous since no helium was present in the flow. Based on these results it was concluded that the existing probe was ineffective in the free-jet facility, with an uncertainty level of no less than 25 percent mole fraction helium. The cause of the high uncertainty and overall ineffectiveness was most likely the probe calibration and data reduction methods. Master of Science 2014-03-14T21:33:24Z 2014-03-14T21:33:24Z 1991 2009-04-08 2009-04-08 2009-04-08 Thesis Text etd-04082009-040935 http://hdl.handle.net/10919/41997 http://scholar.lib.vt.edu/theses/available/etd-04082009-040935/ en OCLC# 25119434 LD5655.V855_1991.M573.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ xi, 109 leaves BTD application/pdf application/pdf Virginia Tech |
collection |
NDLTD |
language |
en |
format |
Others
|
sources |
NDLTD |
topic |
LD5655.V855 1991.M573 Flow injection analysis Jets -- Fluid dynamics |
spellingShingle |
LD5655.V855 1991.M573 Flow injection analysis Jets -- Fluid dynamics Mills, John Richard A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
description |
Inspired by the need to study injectant flow patterns near the test surface, a supersonic free-jet facility was designed and constructed. This facility provides a Mach 1.95 flow over a test section area of 6.35 cm by 5.08 cm. The facility was thoroughly tested and proved that it is durable, versatile, and capable of providing repeatable test conditions. When compared to the main supersonic tunnel at VPI & SU, the free-jet facility has many advantages, including greater optical and spatial access, longer available test durations, and less time needed between tests for the storage tanks to be refilled. As a part of the project, several diagnostic techniques were evaluated in the facility. Normal, sonic injection of helium through a circular injector was studied as a way to evaluate nanoshadowgraph photography, oil flow photography, and infrared imaging as qualitative flow visualization methods. Quantitative measurements of the local helium concentration within the boundary layer were taken to evaluate the effectiveness of an existing hot-film concentration probe. The tests showed that oil flow visualization is a very effective technique in the free-jet facility, producing clear photographs that could be directly scaled. Nanoshadowgraph photography also produced clear photographs of the flow field, although this method was more difficult to implement in the free-jet facility than in the main supersonic tunnel. Finally, infrared imaging, which was not possible in the main supersonic tunnel without major hardware reconfigurations, showed great promise as a method for studying normal injection. Although the tests revealed no conclusive information about injectant flow patterns in the boundary layer, a heat transfer analysis showed that it may be possible in future studies to use this technique as a way to quantitatively measure local helium concentration at the surface. Helium concentration was measured for test cases with both air and helium injection. The measurements were taken at two axial locations with the probe positioned at a distance of 0.1 injector diameters above the test surface. The air injection tests showed helium concentration levels up to 30 percent mole fraction, which is erroneous since no helium was present in the flow. Based on these results it was concluded that the existing probe was ineffective in the free-jet facility, with an uncertainty level of no less than 25 percent mole fraction helium. The cause of the high uncertainty and overall ineffectiveness was most likely the probe calibration and data reduction methods. === Master of Science |
author2 |
Mechanical Engineering |
author_facet |
Mechanical Engineering Mills, John Richard |
author |
Mills, John Richard |
author_sort |
Mills, John Richard |
title |
A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
title_short |
A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
title_full |
A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
title_fullStr |
A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
title_full_unstemmed |
A mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
title_sort |
mach 1.95 free-jet facility for experimental investigation of injectant flow patterns |
publisher |
Virginia Tech |
publishDate |
2014 |
url |
http://hdl.handle.net/10919/41997 http://scholar.lib.vt.edu/theses/available/etd-04082009-040935/ |
work_keys_str_mv |
AT millsjohnrichard amach195freejetfacilityforexperimentalinvestigationofinjectantflowpatterns AT millsjohnrichard mach195freejetfacilityforexperimentalinvestigationofinjectantflowpatterns |
_version_ |
1719461352813101056 |