Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs

The purpose of this research is to evaluate and compare the structural performance of composite floor slabs reinforced with 6 x 6 W1.4/W1.4 welded wire fabric (WWF) and STRUX 90/40 synthetic macro fibers. Slabs were subjected to flexural strength tests and concentrated load tests while monitoring l...

Full description

Bibliographic Details
Main Author: Ordija, James Louis
Other Authors: Civil Engineering
Format: Others
Published: Virginia Tech 2014
Subjects:
Online Access:http://hdl.handle.net/10919/40539
http://scholar.lib.vt.edu/theses/available/etd-01092007-000202/
id ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-40539
record_format oai_dc
spelling ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-405392020-09-29T05:48:13Z Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs Ordija, James Louis Civil Engineering Easterling, William Samuel Murray, Thomas M. Roberts-Wollmann, Carin L. residual strength welded wire fabric secondary reinforcement composite slabs synthetic fibers The purpose of this research is to evaluate and compare the structural performance of composite floor slabs reinforced with 6 x 6 W1.4/W1.4 welded wire fabric (WWF) and STRUX 90/40 synthetic macro fibers. Slabs were subjected to flexural strength tests and concentrated load tests while monitoring load, steel deck strains, and deflections. Test results obtained from this test program were also compared to results from a similar test program conducted in 2001. Tests were also performed to obtain the average residual-strength of the fiber-reinforced concrete using the ASTM C 1399 (2003) standard test. All slabs were loaded until a complete failure was observed. The observed failure loads were compared to failure loads calculated by design guides published by the American Society of Civil Engineers (ASCE) and the Steel Deck Institute (SDI). The flexural strength tests showed that composite slabs reinforced with synthetic macro fibers and WWF exhibited strength and behavior that was almost identical. The observed values of strength were also within the range that was predicted by ASCE prediction models. At a typical office design load of 70 psf, all slabs exhibited midspan deflections that were much smaller than those necessary for serviceability requirements. The concentrated load tests also showed that the observed strength of all composite slabs tested was above those values predicted by ASCE and SDI models. However, an effective comparison between the WWF-reinforced and synthetic macro fiber-reinforced slab was difficult due to a poor shear bond in the latter slab prior to testing. The results of the ASTM C 1399 test verified the ability of concrete reinforced with synthetic macro fibers to meet average residual-strength values recommended by the SDI. Master of Science 2014-03-14T21:26:36Z 2014-03-14T21:26:36Z 2006-12-12 2007-01-09 2007-02-02 2007-02-02 Thesis etd-01092007-000202 http://hdl.handle.net/10919/40539 http://scholar.lib.vt.edu/theses/available/etd-01092007-000202/ Thesis.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ application/pdf Virginia Tech
collection NDLTD
format Others
sources NDLTD
topic residual strength
welded wire fabric
secondary reinforcement
composite slabs
synthetic fibers
spellingShingle residual strength
welded wire fabric
secondary reinforcement
composite slabs
synthetic fibers
Ordija, James Louis
Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
description The purpose of this research is to evaluate and compare the structural performance of composite floor slabs reinforced with 6 x 6 W1.4/W1.4 welded wire fabric (WWF) and STRUX 90/40 synthetic macro fibers. Slabs were subjected to flexural strength tests and concentrated load tests while monitoring load, steel deck strains, and deflections. Test results obtained from this test program were also compared to results from a similar test program conducted in 2001. Tests were also performed to obtain the average residual-strength of the fiber-reinforced concrete using the ASTM C 1399 (2003) standard test. All slabs were loaded until a complete failure was observed. The observed failure loads were compared to failure loads calculated by design guides published by the American Society of Civil Engineers (ASCE) and the Steel Deck Institute (SDI). The flexural strength tests showed that composite slabs reinforced with synthetic macro fibers and WWF exhibited strength and behavior that was almost identical. The observed values of strength were also within the range that was predicted by ASCE prediction models. At a typical office design load of 70 psf, all slabs exhibited midspan deflections that were much smaller than those necessary for serviceability requirements. The concentrated load tests also showed that the observed strength of all composite slabs tested was above those values predicted by ASCE and SDI models. However, an effective comparison between the WWF-reinforced and synthetic macro fiber-reinforced slab was difficult due to a poor shear bond in the latter slab prior to testing. The results of the ASTM C 1399 test verified the ability of concrete reinforced with synthetic macro fibers to meet average residual-strength values recommended by the SDI. === Master of Science
author2 Civil Engineering
author_facet Civil Engineering
Ordija, James Louis
author Ordija, James Louis
author_sort Ordija, James Louis
title Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
title_short Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
title_full Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
title_fullStr Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
title_full_unstemmed Structural Performance of Fiber-Reinforced and Welded Wire Fabric-Reinforced Concrete Composite Slabs
title_sort structural performance of fiber-reinforced and welded wire fabric-reinforced concrete composite slabs
publisher Virginia Tech
publishDate 2014
url http://hdl.handle.net/10919/40539
http://scholar.lib.vt.edu/theses/available/etd-01092007-000202/
work_keys_str_mv AT ordijajameslouis structuralperformanceoffiberreinforcedandweldedwirefabricreinforcedconcretecompositeslabs
_version_ 1719346526201839616