The Viability of Steel-Concrete Composite Girder Bridges with Continuous Profiled Steel Deck
The continuous permanent metal deck form system provides a quick and efficient method of constructing short-span, simply supported composite steel girder bridges. However, because shear studs can only be welded to the girder through the steel deck at rib locations, the number of shear stud locations...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Published: |
Virginia Tech
2014
|
Subjects: | |
Online Access: | http://hdl.handle.net/10919/34208 http://scholar.lib.vt.edu/theses/available/etd-07272009-152909/ |
Summary: | The continuous permanent metal deck form system provides a quick and efficient method
of constructing short-span, simply supported composite steel girder bridges. However, because
shear studs can only be welded to the girder through the steel deck at rib locations, the number of
shear stud locations is limited to the number of ribs in the shear span while the spacing of the
shear studs is restricted to the rib spacing of the steel deck. This results in a condition where
various provisions of the AASHTO LRFD Bridge Design Specifications (2007) cannot be
satisfied, including shear stud fatigue spacing requirements and the fully composite section
requirements.<p>
The purpose of this research was to investigate whether continuous permanent metal deck
form construction method can be used for bridges given the code departures. Using this method,
a full scale test specimen was constructed with one half of the specimen using one stud per rib
and the other half using two studs per rib and then each half was tested separately. The steel deck
used in the specimen was supplied by Wheeling Corrugating. Fatigue testing was conducted to
determine the fatigue resistance of the specimen at both levels of interaction, with load ranges
calculated using the AASHTO LRFD shear stud fatigue equation. This was followed by static
tests to failure to determine the plastic moment capacity at both levels of interaction. Results of
the testing were compared to existing design models and modifications specific to this
construction method are made. Investigations into whether the profiled steel deck can act as full
lateral bracing to the steel girder compression flange during deck placement were also made.
<p>Fatigue testing results showed that very little stiffness was lost over the course of testing
at both levels of composite interaction. This leads to the conclusion that the AASHTO shear
stud equation used for this design is conservative. Static testing results indicated that the
measured values for the plastic moment capacity of the specimen were less than the calculated
capacity. This leads to the conclusion that the individual shear stud strengths were overestimated
using current design equations. Recommendations for modifications to the existing design
equations are provided. === Master of Science |
---|