Further Investigation of Standoff Screws Used in Composite Joists
The purpose of this study is to further evaluate the performance of the 5/16 in. diameter Elco Grade 8 standoff screw as a mechanical shear connector in composite joists. Standoff screws are being investigated as viable an alternative to welded shear studs in short span composite joists. The data...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Published: |
Virginia Tech
2014
|
Subjects: | |
Online Access: | http://hdl.handle.net/10919/31330 http://scholar.lib.vt.edu/theses/available/etd-02242000-11580052/ |
id |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-31330 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-313302020-09-29T05:46:11Z Further Investigation of Standoff Screws Used in Composite Joists Webler, James Edward Structural Engineering and Materials Easterling, William Samuel Murray, Thomas M. Cousins, Thomas E. standoff screws shsear connectors composite joists The purpose of this study is to further evaluate the performance of the 5/16 in. diameter Elco Grade 8 standoff screw as a mechanical shear connector in composite joists. Standoff screws are being investigated as viable an alternative to welded shear studs in short span composite joists. The data and results obtained from 59 pushout tests performed on the 5/16 in. diameter Elco Grade 8 standoff screw are presented. The test parameters investigated in this study include: standoff screw height, quantity of standoff screws per deck rib, standoff screw position, slab depth, base angle thickness, deck type, and amount of transverse reinforcement. Test results gathered in this study are used in conjunction with selected test data from research performed by Alander (1998). This combined test data is used in determining the validity of existing predictive equations for the shear strength of the 5/16 in. diameter Elco Grade 8 standoff screw. The influence of various independent variables on shear strength is investigated for all screw densities tested. The performance of the 5/16 in. diameter Elco Grade 8 standoff screw in solid slab applications is also investigated. Proposed predictive equations for the shear strength of the 5/16 in. diameter Elco Grade 8 standoff screw based on screw-related failure modes, concrete cone failures and longitudinal splitting, are presented. Master of Science 2014-03-14T20:32:07Z 2014-03-14T20:32:07Z 2000-01-14 2000-02-24 2001-03-03 2000-03-03 Thesis etd-02242000-11580052 http://hdl.handle.net/10919/31330 http://scholar.lib.vt.edu/theses/available/etd-02242000-11580052/ etd.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ application/pdf Virginia Tech |
collection |
NDLTD |
format |
Others
|
sources |
NDLTD |
topic |
standoff screws shsear connectors composite joists |
spellingShingle |
standoff screws shsear connectors composite joists Webler, James Edward Further Investigation of Standoff Screws Used in Composite Joists |
description |
The purpose of this study is to further evaluate the performance of the 5/16 in. diameter Elco Grade 8 standoff screw as a mechanical shear connector in composite joists. Standoff screws are being investigated as viable an alternative to welded shear studs in short span composite joists. The data and results obtained from 59 pushout tests performed on the 5/16 in. diameter Elco Grade 8 standoff screw are presented. The test parameters investigated in this study include: standoff screw height, quantity of standoff screws per deck rib, standoff screw position, slab depth, base angle thickness, deck type, and amount of transverse reinforcement.
Test results gathered in this study are used in conjunction with selected test data from research performed by Alander (1998). This combined test data is used in determining the validity of existing predictive equations for the shear strength of the 5/16 in. diameter Elco Grade 8 standoff screw. The influence of various independent variables on shear strength is investigated for all screw densities tested. The performance of the 5/16 in. diameter Elco Grade 8 standoff screw in solid slab applications is also investigated. Proposed predictive equations for the shear strength of the 5/16 in. diameter Elco Grade 8 standoff screw based on screw-related failure modes, concrete cone failures and longitudinal splitting, are presented. === Master of Science |
author2 |
Structural Engineering and Materials |
author_facet |
Structural Engineering and Materials Webler, James Edward |
author |
Webler, James Edward |
author_sort |
Webler, James Edward |
title |
Further Investigation of Standoff Screws Used in Composite Joists |
title_short |
Further Investigation of Standoff Screws Used in Composite Joists |
title_full |
Further Investigation of Standoff Screws Used in Composite Joists |
title_fullStr |
Further Investigation of Standoff Screws Used in Composite Joists |
title_full_unstemmed |
Further Investigation of Standoff Screws Used in Composite Joists |
title_sort |
further investigation of standoff screws used in composite joists |
publisher |
Virginia Tech |
publishDate |
2014 |
url |
http://hdl.handle.net/10919/31330 http://scholar.lib.vt.edu/theses/available/etd-02242000-11580052/ |
work_keys_str_mv |
AT weblerjamesedward furtherinvestigationofstandoffscrewsusedincompositejoists |
_version_ |
1719345997170081792 |