Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency
This work focuses on the safe and stable operation of an autonomous power system interconnecting an AC source with various types of power electronic loads. The stability of these systems is a challenge due to the inherent nonlinearity of the circuits involved. Traditionally, the stability analysis i...
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Published: |
Virginia Tech
2014
|
Subjects: | |
Online Access: | http://hdl.handle.net/10919/29616 http://scholar.lib.vt.edu/theses/available/etd-11162007-141350/ |
id |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-29616 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-296162020-09-26T05:33:44Z Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency Rosado, Sebastian Pedro Electrical and Computer Engineering Kohler, Werner E. Burgos, Rolando Liu, Yilu Centeno, Virgilio A. Wang, Fei Fred Boroyevich, Dushan multi-pulse transformer rectifier stand-alone power systems synchronous generator excitation lyapunov methods voltage stability large-signal stability This work focuses on the safe and stable operation of an autonomous power system interconnecting an AC source with various types of power electronic loads. The stability of these systems is a challenge due to the inherent nonlinearity of the circuits involved. Traditionally, the stability analysis in this type of power systems has been approached by means of small-signal methodology derived from the Nyquist stability criterion. The small-signal analysis combined with physical insight and the adoption of safety margins is sufficient, in many cases, to achieve a stable operation with an acceptable system performance. Nonetheless, in many cases, the margins adopted result in conservative measures and consequent system over designs. This work studies the system stability under large-perturbations by means of three different tools, namely parameter space mapping, energy functions, and time domain simulations. The developed parameters space mapping determines the region of the state and parameter space where the system operation is locally stable. In this way stability margins in terms of physical parameters can be established. Moreover, the boundaries of the identified stability region represent bifurcations of the system where typical nonlinear behavior appears. The second approach, based on the Lyapunov direct method, attempts to determine the region of attraction of an equilibrium point, defined by an operation condition. For this a Lyapunov function based on linear matrix inequalities was constructed and tested on a simplified autonomous system model. In Addition, the third approach simulates the system behavior on a computer using a detailed system model. The higher level of model detail allows identifying unstable behavior difficult to observe when simpler models are used. Because the stability of the autonomous power system is strongly associated with the characteristics of the energy source, an improved voltage controller for the generator is also presented. The generator of an autonomous power system must provide a good performance under a wide variety of regimes. Under these conditions a model based controller is a good solution because it naturally adapts to the changing requirements. To this extent a controller based on the model of a variable frequency synchronous generator has been developed and tested. The results obtained show a considerable improvement performance when compared to previous practices. Ph. D. 2014-03-14T20:18:37Z 2014-03-14T20:18:37Z 2007-09-21 2007-11-16 2008-11-19 2007-11-19 Dissertation etd-11162007-141350 http://hdl.handle.net/10919/29616 http://scholar.lib.vt.edu/theses/available/etd-11162007-141350/ SRosado_dissertation.pdf In Copyright http://rightsstatements.org/vocab/InC/1.0/ application/pdf Virginia Tech |
collection |
NDLTD |
format |
Others
|
sources |
NDLTD |
topic |
multi-pulse transformer rectifier stand-alone power systems synchronous generator excitation lyapunov methods voltage stability large-signal stability |
spellingShingle |
multi-pulse transformer rectifier stand-alone power systems synchronous generator excitation lyapunov methods voltage stability large-signal stability Rosado, Sebastian Pedro Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency |
description |
This work focuses on the safe and stable operation of an autonomous power system interconnecting an AC source with various types of power electronic loads. The stability of these systems is a challenge due to the inherent nonlinearity of the circuits involved. Traditionally, the stability analysis in this type of power systems has been approached by means of small-signal methodology derived from the Nyquist stability criterion. The small-signal analysis combined with physical insight and the adoption of safety margins is sufficient, in many cases, to achieve a stable operation with an acceptable system performance. Nonetheless, in many cases, the margins adopted result in conservative measures and consequent system over designs.
This work studies the system stability under large-perturbations by means of three different tools, namely parameter space mapping, energy functions, and time domain simulations. The developed parameters space mapping determines the region of the state and parameter space where the system operation is locally stable. In this way stability margins in terms of physical parameters can be established. Moreover, the boundaries of the identified stability region represent bifurcations of the system where typical nonlinear behavior appears. The second approach, based on the Lyapunov direct method, attempts to determine the region of attraction of an equilibrium point, defined by an operation condition. For this a Lyapunov function based on linear matrix inequalities was constructed and tested on a simplified autonomous system model. In Addition, the third approach simulates the system behavior on a computer using a detailed system model. The higher level of model detail allows identifying unstable behavior difficult to observe when simpler models are used.
Because the stability of the autonomous power system is strongly associated with the characteristics of the energy source, an improved voltage controller for the generator is also presented. The generator of an autonomous power system must provide a good performance under a wide variety of regimes. Under these conditions a model based controller is a good solution because it naturally adapts to the changing requirements. To this extent a controller based on the model of a variable frequency synchronous generator has been developed and tested. The results obtained show a considerable improvement performance when compared to previous practices. === Ph. D. |
author2 |
Electrical and Computer Engineering |
author_facet |
Electrical and Computer Engineering Rosado, Sebastian Pedro |
author |
Rosado, Sebastian Pedro |
author_sort |
Rosado, Sebastian Pedro |
title |
Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency |
title_short |
Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency |
title_full |
Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency |
title_fullStr |
Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency |
title_full_unstemmed |
Voltage Stability and Control in Autonomous Electric Power Systems with Variable Frequency |
title_sort |
voltage stability and control in autonomous electric power systems with variable frequency |
publisher |
Virginia Tech |
publishDate |
2014 |
url |
http://hdl.handle.net/10919/29616 http://scholar.lib.vt.edu/theses/available/etd-11162007-141350/ |
work_keys_str_mv |
AT rosadosebastianpedro voltagestabilityandcontrolinautonomouselectricpowersystemswithvariablefrequency |
_version_ |
1719341582195359744 |