Evaluation of oxygen uptake rate as an activated sludge process control parameter
A debate currently exists concerning whether or not oxygen uptake rate is a valid control parameter for monitoring the activated sludge process. A laboratory study was conducted to attempt to shed light on the controversy. Two bench-scale reactors were operated at steady state and under shock load....
Main Author: | |
---|---|
Other Authors: | |
Format: | Others |
Language: | en |
Published: |
Virginia Polytechnic Institute and State University
2020
|
Subjects: | |
Online Access: | http://hdl.handle.net/10919/101173 |
id |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-101173 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-VTETD-oai-vtechworks.lib.vt.edu-10919-1011732021-01-13T05:33:48Z Evaluation of oxygen uptake rate as an activated sludge process control parameter Chandra, Sanjay Environmental Engineering LD5655.V855 1987.C529 Oxygen -- Industrial applications Sewage -- Activated sludge process Sewage -- Purification -- Biological treatment A debate currently exists concerning whether or not oxygen uptake rate is a valid control parameter for monitoring the activated sludge process. A laboratory study was conducted to attempt to shed light on the controversy. Two bench-scale reactors were operated at steady state and under shock load. Oxygen uptake rate (OUR) was measured with the BOD bottle technique and with an on-line respirometer. The reliability of the results obtained from the BOD bottle technique was also of interest. No relationship could be deduced between effluent quality and oxygen uptake rate thereby suggesting that the latter would not be useful as a control parameter. As was concluded from the shock load data, the oxygen uptake rate varies very inconsistently at high organic loadings. It was found that the BOD bottle technique completely failed at very high organic loadings and gave meaningless results. The on-line respirometer, in spite of its high sensitivity, gave more realistic and consistent results. M.S. 2020-12-14T16:34:42Z 2020-12-14T16:34:42Z 1987 Thesis Text http://hdl.handle.net/10919/101173 en OCLC# 16369408 In Copyright http://rightsstatements.org/vocab/InC/1.0/ vi, 60 leaves application/pdf application/pdf Virginia Polytechnic Institute and State University |
collection |
NDLTD |
language |
en |
format |
Others
|
sources |
NDLTD |
topic |
LD5655.V855 1987.C529 Oxygen -- Industrial applications Sewage -- Activated sludge process Sewage -- Purification -- Biological treatment |
spellingShingle |
LD5655.V855 1987.C529 Oxygen -- Industrial applications Sewage -- Activated sludge process Sewage -- Purification -- Biological treatment Chandra, Sanjay Evaluation of oxygen uptake rate as an activated sludge process control parameter |
description |
A debate currently exists concerning whether or not oxygen uptake rate is a valid control parameter for monitoring the activated sludge process. A laboratory study was conducted to attempt to shed light on the controversy. Two bench-scale reactors were operated at steady state and under shock load. Oxygen uptake rate (OUR) was measured with the BOD bottle technique and with an on-line respirometer. The reliability of the results obtained from the BOD bottle technique was also of interest.
No relationship could be deduced between effluent quality and oxygen uptake rate thereby suggesting that the latter would not be useful as a control parameter. As was concluded from the shock load data, the oxygen uptake rate varies very inconsistently at high organic loadings.
It was found that the BOD bottle technique completely failed at very high organic loadings and gave meaningless results. The on-line respirometer, in spite of its high sensitivity, gave more realistic and consistent results. === M.S. |
author2 |
Environmental Engineering |
author_facet |
Environmental Engineering Chandra, Sanjay |
author |
Chandra, Sanjay |
author_sort |
Chandra, Sanjay |
title |
Evaluation of oxygen uptake rate as an activated sludge process control parameter |
title_short |
Evaluation of oxygen uptake rate as an activated sludge process control parameter |
title_full |
Evaluation of oxygen uptake rate as an activated sludge process control parameter |
title_fullStr |
Evaluation of oxygen uptake rate as an activated sludge process control parameter |
title_full_unstemmed |
Evaluation of oxygen uptake rate as an activated sludge process control parameter |
title_sort |
evaluation of oxygen uptake rate as an activated sludge process control parameter |
publisher |
Virginia Polytechnic Institute and State University |
publishDate |
2020 |
url |
http://hdl.handle.net/10919/101173 |
work_keys_str_mv |
AT chandrasanjay evaluationofoxygenuptakerateasanactivatedsludgeprocesscontrolparameter |
_version_ |
1719372633261211648 |