Effect of galvanization on the fatigue strength of high mast illumination poles

This research investigation studied the effects of galvanization on the fatigue life of high mast illumination poles. Reports that galvanization of high masts caused initial cracks to form at the toe of the weld connecting the base plate to the shaft of the pole were first validated. The effects o...

Full description

Bibliographic Details
Main Author: Pool, Charles Stephen
Format: Others
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/2152/ETD-UT-2010-05-1442
id ndltd-UTEXAS-oai-repositories.lib.utexas.edu-2152-ETD-UT-2010-05-1442
record_format oai_dc
spelling ndltd-UTEXAS-oai-repositories.lib.utexas.edu-2152-ETD-UT-2010-05-14422015-09-20T16:55:32ZEffect of galvanization on the fatigue strength of high mast illumination polesPool, Charles StephenSteelFatigueHigh mast illumination polesGalvanizingThis research investigation studied the effects of galvanization on the fatigue life of high mast illumination poles. Reports that galvanization of high masts caused initial cracks to form at the toe of the weld connecting the base plate to the shaft of the pole were first validated. The effects of these initial cracks on fatigue strength were then checked through experimental testing. A variety of variables were tested for both their effects on the occurrences of the initial cracks and effects on fatigue life. These variables included testing galvanized against ungalvanized specimens, testing of varying fabricators and galvanizers, and testing of various types of connection details. These test results were compared against inspection results provided by Texas Department of Transportation inspectors. Also, methods of mitigating the effects of toe cracks on the fatigue life of poles were investigated. A method for repairing specimens both in the fabrication shop and in the field were developed and tested. Both methods showed strong improvement in fatigue life of the specimens providing a possible repair solution.text2010-11-05T15:22:22Z2010-11-05T15:22:31Z2010-11-05T15:22:22Z2010-11-05T15:22:31Z2010-052010-11-05May 20102010-11-05T15:22:31Zthesisapplication/pdfhttp://hdl.handle.net/2152/ETD-UT-2010-05-1442eng
collection NDLTD
language English
format Others
sources NDLTD
topic Steel
Fatigue
High mast illumination poles
Galvanizing
spellingShingle Steel
Fatigue
High mast illumination poles
Galvanizing
Pool, Charles Stephen
Effect of galvanization on the fatigue strength of high mast illumination poles
description This research investigation studied the effects of galvanization on the fatigue life of high mast illumination poles. Reports that galvanization of high masts caused initial cracks to form at the toe of the weld connecting the base plate to the shaft of the pole were first validated. The effects of these initial cracks on fatigue strength were then checked through experimental testing. A variety of variables were tested for both their effects on the occurrences of the initial cracks and effects on fatigue life. These variables included testing galvanized against ungalvanized specimens, testing of varying fabricators and galvanizers, and testing of various types of connection details. These test results were compared against inspection results provided by Texas Department of Transportation inspectors. Also, methods of mitigating the effects of toe cracks on the fatigue life of poles were investigated. A method for repairing specimens both in the fabrication shop and in the field were developed and tested. Both methods showed strong improvement in fatigue life of the specimens providing a possible repair solution. === text
author Pool, Charles Stephen
author_facet Pool, Charles Stephen
author_sort Pool, Charles Stephen
title Effect of galvanization on the fatigue strength of high mast illumination poles
title_short Effect of galvanization on the fatigue strength of high mast illumination poles
title_full Effect of galvanization on the fatigue strength of high mast illumination poles
title_fullStr Effect of galvanization on the fatigue strength of high mast illumination poles
title_full_unstemmed Effect of galvanization on the fatigue strength of high mast illumination poles
title_sort effect of galvanization on the fatigue strength of high mast illumination poles
publishDate 2010
url http://hdl.handle.net/2152/ETD-UT-2010-05-1442
work_keys_str_mv AT poolcharlesstephen effectofgalvanizationonthefatiguestrengthofhighmastilluminationpoles
_version_ 1716821047247896576