Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts

Brackish waters are now considered valuable alternative water resources. Reverse osmosis (RO) membranes are the most promising candidate for drinking water production through desalination. Low recovery (the fraction of influent water that becomes product water) prevents widespread application of RO...

Full description

Bibliographic Details
Main Author: Greenlee, Lauren Fay
Format: Others
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/2152/6873
id ndltd-UTEXAS-oai-repositories.lib.utexas.edu-2152-6873
record_format oai_dc
spelling ndltd-UTEXAS-oai-repositories.lib.utexas.edu-2152-68732015-09-20T16:53:37ZEnhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate saltsGreenlee, Lauren FayReverse osmosis desalinationAntiscalantsPrecipitate saltsBrackish waters are now considered valuable alternative water resources. Reverse osmosis (RO) membranes are the most promising candidate for drinking water production through desalination. Low recovery (the fraction of influent water that becomes product water) prevents widespread application of RO inland because of the high cost of waste disposal. The recovery of a brackish RO system is limited by sparingly soluble salts that become supersaturated and precipitate on the membrane surface. Precipitation is controlled through pH adjustment and antiscalant addition; however, at high salt supersaturation, antiscalant control is overcome and precipitation occurs. To further increase RO recovery and avoid precipitation, a three-stage process treated the waste stream (concentrate) of a brackish water RO system through antiscalant degradation, salt precipitation, and solid/liquid separation. Ozone (O3) and hydrogen peroxide (H2O2) were used to degrade antiscalants, pH elevation and base (NaOH/NaHCO3) addition were used to precipitate sparingly soluble salts, and microfiltration (0.1 μm) was used to separate precipitated solids from the water. Optimal parameters (pH, ozone dose, H2O2/O3 ratio, antiscalant type and concentration, water composition) for antiscalant oxidation were determined. The influence of antiscalant type and concentration and pH was investigated for the precipitation and filtration stages. Results were obtained for particle size distribution, extent of precipitation, particle morphology, and particle composition. The effect of ozonation on precipitation and filtration was evaluated, with a comparison to two-stage treatment consisting of precipitation and filtration. Antiscalant oxidation is controlled by bivalent cation coordination, while pH and ozone dose significantly affect the extent of oxidation. The addition of antiscalant prior to precipitation caused changes to particle size and morphology, and results varied with water composition and antiscalant type and concentration. Ozonation, even for small times such as one minute, prior to precipitation and filtration increased calcium precipitation and decomposed the antiscalant enough to remove the effect of the antiscalant on particle characteristics. During ozonation, antiscalants were not completely oxidized, but the partial oxidation products did not seem to affect precipitation. Ozonation also reduced the fouling of microfiltration membranes used for solid/liquid separation. Results indicated concentrate treatment can significantly increase the overall recovery of an RO system.text2010-02-04T15:15:42Z2010-02-04T15:15:42Z2009-082010-02-04T15:15:42Zelectronichttp://hdl.handle.net/2152/6873engCopyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.
collection NDLTD
language English
format Others
sources NDLTD
topic Reverse osmosis desalination
Antiscalants
Precipitate salts
spellingShingle Reverse osmosis desalination
Antiscalants
Precipitate salts
Greenlee, Lauren Fay
Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
description Brackish waters are now considered valuable alternative water resources. Reverse osmosis (RO) membranes are the most promising candidate for drinking water production through desalination. Low recovery (the fraction of influent water that becomes product water) prevents widespread application of RO inland because of the high cost of waste disposal. The recovery of a brackish RO system is limited by sparingly soluble salts that become supersaturated and precipitate on the membrane surface. Precipitation is controlled through pH adjustment and antiscalant addition; however, at high salt supersaturation, antiscalant control is overcome and precipitation occurs. To further increase RO recovery and avoid precipitation, a three-stage process treated the waste stream (concentrate) of a brackish water RO system through antiscalant degradation, salt precipitation, and solid/liquid separation. Ozone (O3) and hydrogen peroxide (H2O2) were used to degrade antiscalants, pH elevation and base (NaOH/NaHCO3) addition were used to precipitate sparingly soluble salts, and microfiltration (0.1 μm) was used to separate precipitated solids from the water. Optimal parameters (pH, ozone dose, H2O2/O3 ratio, antiscalant type and concentration, water composition) for antiscalant oxidation were determined. The influence of antiscalant type and concentration and pH was investigated for the precipitation and filtration stages. Results were obtained for particle size distribution, extent of precipitation, particle morphology, and particle composition. The effect of ozonation on precipitation and filtration was evaluated, with a comparison to two-stage treatment consisting of precipitation and filtration. Antiscalant oxidation is controlled by bivalent cation coordination, while pH and ozone dose significantly affect the extent of oxidation. The addition of antiscalant prior to precipitation caused changes to particle size and morphology, and results varied with water composition and antiscalant type and concentration. Ozonation, even for small times such as one minute, prior to precipitation and filtration increased calcium precipitation and decomposed the antiscalant enough to remove the effect of the antiscalant on particle characteristics. During ozonation, antiscalants were not completely oxidized, but the partial oxidation products did not seem to affect precipitation. Ozonation also reduced the fouling of microfiltration membranes used for solid/liquid separation. Results indicated concentrate treatment can significantly increase the overall recovery of an RO system. === text
author Greenlee, Lauren Fay
author_facet Greenlee, Lauren Fay
author_sort Greenlee, Lauren Fay
title Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
title_short Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
title_full Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
title_fullStr Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
title_full_unstemmed Enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
title_sort enhancing recovery of reverse osmosis desalination : side-stream oxidation of antiscalants to precipitate salts
publishDate 2010
url http://hdl.handle.net/2152/6873
work_keys_str_mv AT greenleelaurenfay enhancingrecoveryofreverseosmosisdesalinationsidestreamoxidationofantiscalantstoprecipitatesalts
_version_ 1716820754819973121