Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere

In-situ composition measurements of the mesosphere/lower thermosphere (MLT) are challenging; this region is only accessible via high-speed sounding rockets, ambient pressures extend into the 10-3 Torr range, and particles of interest range in mass from electrons to meteoric smoke and dust particles....

Full description

Bibliographic Details
Main Author: Everett, E. Addison
Format: Others
Published: DigitalCommons@USU 2017
Subjects:
Online Access:https://digitalcommons.usu.edu/etd/5698
https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6784&context=etd
id ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-6784
record_format oai_dc
spelling ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-67842019-10-13T05:39:08Z Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere Everett, E. Addison In-situ composition measurements of the mesosphere/lower thermosphere (MLT) are challenging; this region is only accessible via high-speed sounding rockets, ambient pressures extend into the 10-3 Torr range, and particles of interest range in mass from electrons to meteoric smoke and dust particles. Time-of-flight mass spectrometers (TOF-MS) are capable of making fast, accurate measurements over a wide mass range. However, since they rely on pressure-sensitive microchannel plate (MCP) detectors and high voltages, they have rarely been applied at these altitudes. A new TOF-MS for making in-situ composition measurements in the MLT has been developed at the Space Dynamics Laboratory. This instrument employs modest acceleration potentials and a pressure-tolerant MCP detector. A Bradbury-Nielsen gate is used to produce short, well-defined ion pulses to reduce the temporal and spatial uncertainty of sampled ions. A prototype TOF-MS was constructed and used to demonstrate TOF-MS technology under conditions relevant to in-situ MLT measurements. Operational boundaries and capabilities of this new instrument were identified through laboratory experiments combined with computer modeling. The prototype instrument achieved a maximum resolution of 100 at m/z 40 (Ar), sufficient to resolve major atmospheric species of interest. During experiments at elevated pressures, the MCP detector maintained low background count rates (/second) at pressures as high as 10-3 Torr. A novel getter-based vacuum system was evaluated for use with the new TOF-MS, and a computer model was developed to simulate instrument pressure during a rocket flight. Results from these experiments suggest that when combined with an appropriately sized sampling aperture, this pumping system can extend the measurement range of the instrument to lower altitudes by 10 – 20 km, compared to an unpumped instrument. A computer model was developed to study the effects of critical operating parameters on instrument performance; the most important factor affecting resolution was found to be the initial energy spread of sampled ions. Sensitivity and number density measurement analyses suggest the new instrument will measure major species in the MLT at better than 10% uncertainty. Composition measurements made with the new TOF-MS will contribute to a better understanding of the MLT. 2017-05-01T07:00:00Z text application/pdf https://digitalcommons.usu.edu/etd/5698 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6784&context=etd Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu. All Graduate Theses and Dissertations DigitalCommons@USU Composition Mass Spectrometry Mesosphere Microchannel plate detector Thermosphere Vacuum Atmospheric Sciences Physics
collection NDLTD
format Others
sources NDLTD
topic Composition
Mass Spectrometry
Mesosphere
Microchannel plate detector
Thermosphere
Vacuum
Atmospheric Sciences
Physics
spellingShingle Composition
Mass Spectrometry
Mesosphere
Microchannel plate detector
Thermosphere
Vacuum
Atmospheric Sciences
Physics
Everett, E. Addison
Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
description In-situ composition measurements of the mesosphere/lower thermosphere (MLT) are challenging; this region is only accessible via high-speed sounding rockets, ambient pressures extend into the 10-3 Torr range, and particles of interest range in mass from electrons to meteoric smoke and dust particles. Time-of-flight mass spectrometers (TOF-MS) are capable of making fast, accurate measurements over a wide mass range. However, since they rely on pressure-sensitive microchannel plate (MCP) detectors and high voltages, they have rarely been applied at these altitudes. A new TOF-MS for making in-situ composition measurements in the MLT has been developed at the Space Dynamics Laboratory. This instrument employs modest acceleration potentials and a pressure-tolerant MCP detector. A Bradbury-Nielsen gate is used to produce short, well-defined ion pulses to reduce the temporal and spatial uncertainty of sampled ions. A prototype TOF-MS was constructed and used to demonstrate TOF-MS technology under conditions relevant to in-situ MLT measurements. Operational boundaries and capabilities of this new instrument were identified through laboratory experiments combined with computer modeling. The prototype instrument achieved a maximum resolution of 100 at m/z 40 (Ar), sufficient to resolve major atmospheric species of interest. During experiments at elevated pressures, the MCP detector maintained low background count rates (/second) at pressures as high as 10-3 Torr. A novel getter-based vacuum system was evaluated for use with the new TOF-MS, and a computer model was developed to simulate instrument pressure during a rocket flight. Results from these experiments suggest that when combined with an appropriately sized sampling aperture, this pumping system can extend the measurement range of the instrument to lower altitudes by 10 – 20 km, compared to an unpumped instrument. A computer model was developed to study the effects of critical operating parameters on instrument performance; the most important factor affecting resolution was found to be the initial energy spread of sampled ions. Sensitivity and number density measurement analyses suggest the new instrument will measure major species in the MLT at better than 10% uncertainty. Composition measurements made with the new TOF-MS will contribute to a better understanding of the MLT.
author Everett, E. Addison
author_facet Everett, E. Addison
author_sort Everett, E. Addison
title Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
title_short Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
title_full Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
title_fullStr Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
title_full_unstemmed Design and Characterization of a Time-of-Flight Mass Spectrometer for Composition Measurements in the Upper Atmosphere
title_sort design and characterization of a time-of-flight mass spectrometer for composition measurements in the upper atmosphere
publisher DigitalCommons@USU
publishDate 2017
url https://digitalcommons.usu.edu/etd/5698
https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6784&context=etd
work_keys_str_mv AT everetteaddison designandcharacterizationofatimeofflightmassspectrometerforcompositionmeasurementsintheupperatmosphere
_version_ 1719266114934931456