An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays

The development of an automated instrument employing reflectance colorimetry was described. Several models were designed, assembled, and programmed to perform microbial and enzymic tests automatically. Samples were prepared manually or automatically by a Zymate™ II robot. These samples were incubate...

Full description

Bibliographic Details
Main Author: Yuan, Tsz-Ching
Format: Others
Published: DigitalCommons@USU 1991
Subjects:
Online Access:https://digitalcommons.usu.edu/etd/5382
https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6438&context=etd
id ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-6438
record_format oai_dc
spelling ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-64382019-10-13T06:09:32Z An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays Yuan, Tsz-Ching The development of an automated instrument employing reflectance colorimetry was described. Several models were designed, assembled, and programmed to perform microbial and enzymic tests automatically. Samples were prepared manually or automatically by a Zymate™ II robot. These samples were incubated during the tests to maintain an optimum temperature for reactions and microbial growth. During incubation, color changes of appropriate indicator dyes in the sample/reagent mixtures were measured intermittently, recorded, and compared to previously defined end points. The computer-controlled instrument received data that related time of color changes with the initial numbers of microorganisms or the enzyme activity of the samples. Traditional pH and oxidation/reduction dyes were used. Suitable dyes and media were selected for fast estimation in the different assays studied . Applications of the instrument to evaluate raw milk for the total viable microbial count, abnormality, broad spectrum antibiotics, and coliforms were emphasized. The automated colorimeter system successfully quantitated total and coliform microflora in raw milk. Correlations between reflectance colorimetry and the spiral plate count method were .932 (using .12% TIC as indicator), .922 (using BCP as indicator), and .681 (using .04% TTC as indicator). A coefficient of correlation of .874 was obtained when reflectance colorimetry was compared with coliform numbers on violet red bile agar. The reflectance colorimetry system provided better precision than current reference methods. Preliminary incubation or larger sample volumes were required to estimate low numbers of microflora . Antibiotic residue detection was also evaluated using Lactococcus lactis ssp. cremoris UC 310+ with the automated colorimeter system. The following concentrations (ppb) could be detected: penicillin G:::;; 5, ampicillin ≤ 5, tetracycline ≤ 250 , sulfamethazine ≤ 30, streptomycin ≤ 1000, kanamycin ≤ 500, and chloramphenicol ≤ 500. Abnormal milk could be screened out by measuring the NAGase activity and chloride ion content in milk samples. Both methods had been integrated into the automated colorimeter system. The coefficient of correlation between somatic cell count and the NAGase activity as measured with the colorimeter was .802; a correlation of .792 could be obtained when chloride ion content was measured. 1991-05-01T07:00:00Z text application/pdf https://digitalcommons.usu.edu/etd/5382 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6438&context=etd Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu. All Graduate Theses and Dissertations DigitalCommons@USU Color Meter Microbiological Enzymic Assays Automated Reflectance Food Science
collection NDLTD
format Others
sources NDLTD
topic Color Meter
Microbiological
Enzymic
Assays
Automated
Reflectance
Food Science
spellingShingle Color Meter
Microbiological
Enzymic
Assays
Automated
Reflectance
Food Science
Yuan, Tsz-Ching
An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays
description The development of an automated instrument employing reflectance colorimetry was described. Several models were designed, assembled, and programmed to perform microbial and enzymic tests automatically. Samples were prepared manually or automatically by a Zymate™ II robot. These samples were incubated during the tests to maintain an optimum temperature for reactions and microbial growth. During incubation, color changes of appropriate indicator dyes in the sample/reagent mixtures were measured intermittently, recorded, and compared to previously defined end points. The computer-controlled instrument received data that related time of color changes with the initial numbers of microorganisms or the enzyme activity of the samples. Traditional pH and oxidation/reduction dyes were used. Suitable dyes and media were selected for fast estimation in the different assays studied . Applications of the instrument to evaluate raw milk for the total viable microbial count, abnormality, broad spectrum antibiotics, and coliforms were emphasized. The automated colorimeter system successfully quantitated total and coliform microflora in raw milk. Correlations between reflectance colorimetry and the spiral plate count method were .932 (using .12% TIC as indicator), .922 (using BCP as indicator), and .681 (using .04% TTC as indicator). A coefficient of correlation of .874 was obtained when reflectance colorimetry was compared with coliform numbers on violet red bile agar. The reflectance colorimetry system provided better precision than current reference methods. Preliminary incubation or larger sample volumes were required to estimate low numbers of microflora . Antibiotic residue detection was also evaluated using Lactococcus lactis ssp. cremoris UC 310+ with the automated colorimeter system. The following concentrations (ppb) could be detected: penicillin G:::;; 5, ampicillin ≤ 5, tetracycline ≤ 250 , sulfamethazine ≤ 30, streptomycin ≤ 1000, kanamycin ≤ 500, and chloramphenicol ≤ 500. Abnormal milk could be screened out by measuring the NAGase activity and chloride ion content in milk samples. Both methods had been integrated into the automated colorimeter system. The coefficient of correlation between somatic cell count and the NAGase activity as measured with the colorimeter was .802; a correlation of .792 could be obtained when chloride ion content was measured.
author Yuan, Tsz-Ching
author_facet Yuan, Tsz-Ching
author_sort Yuan, Tsz-Ching
title An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays
title_short An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays
title_full An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays
title_fullStr An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays
title_full_unstemmed An Automated Reflectance Color Meter Instrument for Microbiological and Enzymic Assays
title_sort automated reflectance color meter instrument for microbiological and enzymic assays
publisher DigitalCommons@USU
publishDate 1991
url https://digitalcommons.usu.edu/etd/5382
https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6438&context=etd
work_keys_str_mv AT yuantszching anautomatedreflectancecolormeterinstrumentformicrobiologicalandenzymicassays
AT yuantszching automatedreflectancecolormeterinstrumentformicrobiologicalandenzymicassays
_version_ 1719267776740196352