Detection of Abnormal Milk with Impedance Microbiology Instrumentation
Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25'C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module w...
Main Author: | |
---|---|
Format: | Others |
Published: |
DigitalCommons@USU
1986
|
Subjects: | |
Online Access: | https://digitalcommons.usu.edu/etd/5332 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6382&context=etd |
id |
ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-6382 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UTAHS-oai-digitalcommons.usu.edu-etd-63822019-10-13T06:04:57Z Detection of Abnormal Milk with Impedance Microbiology Instrumentation Khayat, Fahad Ali Abdulghany Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25'C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module wells. Samples blended from four quarters of a cow indicated milk from one quarter was abnormal if the salt level in the abnormal quarter raised the blend conductivity above that of normal samples and variance among the wells. Either solid or liquid substrates that contained bacterial stimulants could be used to accelerate bacterial acid production or to reduce impedance detection times, each without adversely affecting the ability to detect abnormal milk. However, measurements with liquid substrates varied with the volume of sample in the well. Results suggested that a fixed volume of one ml be used. Such a volume would allow simultaneous detection of abnormal milk and bacterial load on the same sample. 1986-05-01T07:00:00Z text application/pdf https://digitalcommons.usu.edu/etd/5332 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6382&context=etd Copyright for this work is held by the author. Transmission or reproduction of materials protected by copyright beyond that allowed by fair use requires the written permission of the copyright owners. Works not in the public domain cannot be commercially exploited without permission of the copyright owner. Responsibility for any use rests exclusively with the user. For more information contact digitalcommons@usu.edu. All Graduate Theses and Dissertations DigitalCommons@USU Abnormal Milk impedance microbiology instrumentation Biology Life Sciences |
collection |
NDLTD |
format |
Others
|
sources |
NDLTD |
topic |
Abnormal Milk impedance microbiology instrumentation Biology Life Sciences |
spellingShingle |
Abnormal Milk impedance microbiology instrumentation Biology Life Sciences Khayat, Fahad Ali Abdulghany Detection of Abnormal Milk with Impedance Microbiology Instrumentation |
description |
Mastitic milk was detected by obtaining conductance measurements using an impedance microbiology Bactometer® 120 SC instruments. Conductance readings taken after 30 min at 25'C separated normal and abnormal milks when readings differed by more than 3% from the variance among instrument module wells. Samples blended from four quarters of a cow indicated milk from one quarter was abnormal if the salt level in the abnormal quarter raised the blend conductivity above that of normal samples and variance among the wells. Either solid or liquid substrates that contained bacterial stimulants could be used to accelerate bacterial acid production or to reduce impedance detection times, each without adversely affecting the ability to detect abnormal milk. However, measurements with liquid substrates varied with the volume of sample in the well. Results suggested that a fixed volume of one ml be used. Such a volume would allow simultaneous detection of abnormal milk and bacterial load on the same sample. |
author |
Khayat, Fahad Ali Abdulghany |
author_facet |
Khayat, Fahad Ali Abdulghany |
author_sort |
Khayat, Fahad Ali Abdulghany |
title |
Detection of Abnormal Milk with Impedance Microbiology Instrumentation |
title_short |
Detection of Abnormal Milk with Impedance Microbiology Instrumentation |
title_full |
Detection of Abnormal Milk with Impedance Microbiology Instrumentation |
title_fullStr |
Detection of Abnormal Milk with Impedance Microbiology Instrumentation |
title_full_unstemmed |
Detection of Abnormal Milk with Impedance Microbiology Instrumentation |
title_sort |
detection of abnormal milk with impedance microbiology instrumentation |
publisher |
DigitalCommons@USU |
publishDate |
1986 |
url |
https://digitalcommons.usu.edu/etd/5332 https://digitalcommons.usu.edu/cgi/viewcontent.cgi?article=6382&context=etd |
work_keys_str_mv |
AT khayatfahadaliabdulghany detectionofabnormalmilkwithimpedancemicrobiologyinstrumentation |
_version_ |
1719267770932133888 |