Feasibility of Wearable Sensors to Determine Gait Parameters

A wearable system that can be used in different settings to collect gait parameters on subjects with a mild traumatic brain injury (mTBI) would allow clinicians to collect needed data of subjects outside of the laboratory setting. Mild traumatic brain injuries stem from a number of causes such as il...

Full description

Bibliographic Details
Main Author: Simoes, Mario Alves
Format: Others
Published: Scholar Commons 2011
Subjects:
Online Access:http://scholarcommons.usf.edu/etd/3346
http://scholarcommons.usf.edu/cgi/viewcontent.cgi?article=4541&context=etd
id ndltd-USF-oai-scholarcommons.usf.edu-etd-4541
record_format oai_dc
spelling ndltd-USF-oai-scholarcommons.usf.edu-etd-45412015-09-30T04:40:59Z Feasibility of Wearable Sensors to Determine Gait Parameters Simoes, Mario Alves A wearable system that can be used in different settings to collect gait parameters on subjects with a mild traumatic brain injury (mTBI) would allow clinicians to collect needed data of subjects outside of the laboratory setting. Mild traumatic brain injuries stem from a number of causes such as illnesses, strokes, accidents or battlefield traumas. These injuries can cause issues with everyday tasks, such as gait, and are linked with vestibular dysfunction [1]. Different wearable sensor systems were analyzed prior to starting this study along with relevant gait parameters associated with mild traumatic brain injury. To monitor gait parameters relevant to mild traumatic brain injury (cadence, torso rate of rotation, head rate of rotation and stride length) a wearable sensor system was selected (APDM Opal Movement Monitor [13]) and compared against the gold standard optical tracking system (Vicon) [2]. A group of ten, 20-27 year old, healthy subjects were used to validate the APDM Movement Monitor system using the Pearson's R correlation value [35]. Subjects were asked to wear the APDM movement monitors in conjunction with the reflective markers of the Vicon system while performing three sessions of gait trials: a normal gait speed, a fast gait speed and a slow gait speed. Using the Pearson's R correlation values, cadence, torso rate of rotation, and head rate of rotation were found to be highly correlated between both systems. The Pearson's R correlations for cadence, torso rate of rotation, head rate of rotation and stride length were 0.967, 0.907, 0.942, and 0.861, respectively. These correlation values suggest the gait parameters relevant to mild traumatic brain injury are highly correlated between both the APDM Movement Monitor system and the Vicon system, and APDM's wearable sensor system was lightweight, portable and less costly than the Vicon system. 2011-01-01T08:00:00Z text application/pdf http://scholarcommons.usf.edu/etd/3346 http://scholarcommons.usf.edu/cgi/viewcontent.cgi?article=4541&context=etd default Graduate Theses and Dissertations Scholar Commons APDM Cadence mTBI Stride Length Vicon American Studies Arts and Humanities Biomedical Engineering and Bioengineering Engineering
collection NDLTD
format Others
sources NDLTD
topic APDM
Cadence
mTBI
Stride Length
Vicon
American Studies
Arts and Humanities
Biomedical Engineering and Bioengineering
Engineering
spellingShingle APDM
Cadence
mTBI
Stride Length
Vicon
American Studies
Arts and Humanities
Biomedical Engineering and Bioengineering
Engineering
Simoes, Mario Alves
Feasibility of Wearable Sensors to Determine Gait Parameters
description A wearable system that can be used in different settings to collect gait parameters on subjects with a mild traumatic brain injury (mTBI) would allow clinicians to collect needed data of subjects outside of the laboratory setting. Mild traumatic brain injuries stem from a number of causes such as illnesses, strokes, accidents or battlefield traumas. These injuries can cause issues with everyday tasks, such as gait, and are linked with vestibular dysfunction [1]. Different wearable sensor systems were analyzed prior to starting this study along with relevant gait parameters associated with mild traumatic brain injury. To monitor gait parameters relevant to mild traumatic brain injury (cadence, torso rate of rotation, head rate of rotation and stride length) a wearable sensor system was selected (APDM Opal Movement Monitor [13]) and compared against the gold standard optical tracking system (Vicon) [2]. A group of ten, 20-27 year old, healthy subjects were used to validate the APDM Movement Monitor system using the Pearson's R correlation value [35]. Subjects were asked to wear the APDM movement monitors in conjunction with the reflective markers of the Vicon system while performing three sessions of gait trials: a normal gait speed, a fast gait speed and a slow gait speed. Using the Pearson's R correlation values, cadence, torso rate of rotation, and head rate of rotation were found to be highly correlated between both systems. The Pearson's R correlations for cadence, torso rate of rotation, head rate of rotation and stride length were 0.967, 0.907, 0.942, and 0.861, respectively. These correlation values suggest the gait parameters relevant to mild traumatic brain injury are highly correlated between both the APDM Movement Monitor system and the Vicon system, and APDM's wearable sensor system was lightweight, portable and less costly than the Vicon system.
author Simoes, Mario Alves
author_facet Simoes, Mario Alves
author_sort Simoes, Mario Alves
title Feasibility of Wearable Sensors to Determine Gait Parameters
title_short Feasibility of Wearable Sensors to Determine Gait Parameters
title_full Feasibility of Wearable Sensors to Determine Gait Parameters
title_fullStr Feasibility of Wearable Sensors to Determine Gait Parameters
title_full_unstemmed Feasibility of Wearable Sensors to Determine Gait Parameters
title_sort feasibility of wearable sensors to determine gait parameters
publisher Scholar Commons
publishDate 2011
url http://scholarcommons.usf.edu/etd/3346
http://scholarcommons.usf.edu/cgi/viewcontent.cgi?article=4541&context=etd
work_keys_str_mv AT simoesmarioalves feasibilityofwearablesensorstodeterminegaitparameters
_version_ 1716825317348212736