High cycle (fatigue) resistance of reinforced concrete beams with lap splices

<p>The development of current design standards for reinforced concrete beams containing lap splices has been mainly aimed at preventing failures due to static (monotonic) loading, or low cycle, high intensity (seismic) loading. However, little consideration has been given in these standards or...

Full description

Bibliographic Details
Main Author: Afseth, Jeffrey G.
Other Authors: none
Format: Others
Language:en
Published: University of Saskatchewan 2013
Subjects:
Online Access:http://library.usask.ca/theses/available/etd-01152013-124631/
id ndltd-USASK-oai-usask.ca-etd-01152013-124631
record_format oai_dc
spelling ndltd-USASK-oai-usask.ca-etd-01152013-1246312013-01-17T10:00:28Z High cycle (fatigue) resistance of reinforced concrete beams with lap splices Afseth, Jeffrey G. <p>The development of current design standards for reinforced concrete beams containing lap splices has been mainly aimed at preventing failures due to static (monotonic) loading, or low cycle, high intensity (seismic) loading. However, little consideration has been given in these standards or in previous research to the performance of lap splices when subjected to high cycle, low intensity (fatigue) loading. Also, recently proposed design equations for lap splices under static loading will permit shorter lap lengths. For these reasons, a study was initiated to investigate the fatigue resistance of reinforced concrete beams with lap splices. A principal variable in this research program was the degree of transverse reinforcement (stirrups) which was provided along the lap splice.</p> <p>The specimens used in this experimental program were seven meters in length, with a cross section 330 mm wide and 508 mm deep, and were reinforced with two No. 30 Grade 400 bars, top and bottom. A lap splice was provided in the bottom tension bars situated in a constant moment region created by a symmetrical two point loading system. The lap splice length and confinement were designed according to ACI Committee 408 recommendations for static loading.</p> <p>Two different lap splice configurations were provided for the test specimens. The first used the maximum number of stirrups that were deemed to be effective for static loading, permitting a shorter lap length. In the second configuration nominal stirrups were provided to the splice at a spacing of one half the effective beam depth, requiring a longer lap length. Failure of the specimens with the heavier stirrups occurred from fatigue of the tensile reinforcing steel and showed similar fatigue resistance to beams containing continuous reinforcement. The specimens with nominal stirrups usually resulted in a splice failure after fewer load cycles, after splitting and delamination of the concrete confining the lap had occurred.</p> <p>Both beams had a similar static bond resistance; however, the beams with the heavier stirrup confinement (shorter lap length) displayed a greater fatigue resistance than the beams with lighter stirrups (longer lap length). These results are in agreement with conclusions reached for seismic loading conditions, which found that splice confinement provided by a high degree of transverse reinforcement is required under cyclic loading to offset the rapid deterioration of the concrete cover confinement.</p> none University of Saskatchewan 2013-01-15 text application/pdf http://library.usask.ca/theses/available/etd-01152013-124631/ http://library.usask.ca/theses/available/etd-01152013-124631/ en unrestricted I hereby certify that, if appropriate, I have obtained and attached hereto a written permission statement from the owner(s) of each third party copyrighted matter to be included in my thesis, dissertation, or project report, allowing distribution as specified below. I certify that the version I submitted is the same as that approved by my advisory committee. I hereby grant to University of Saskatchewan or its agents the non-exclusive license to archive and make accessible, under the conditions specified below, my thesis, dissertation, or project report in whole or in part in all forms of media, now or hereafter known. I retain all other ownership rights to the copyright of the thesis, dissertation or project report. I also retain the right to use in future works (such as articles or books) all or part of this thesis, dissertation, or project report.
collection NDLTD
language en
format Others
sources NDLTD
topic
spellingShingle
Afseth, Jeffrey G.
High cycle (fatigue) resistance of reinforced concrete beams with lap splices
description <p>The development of current design standards for reinforced concrete beams containing lap splices has been mainly aimed at preventing failures due to static (monotonic) loading, or low cycle, high intensity (seismic) loading. However, little consideration has been given in these standards or in previous research to the performance of lap splices when subjected to high cycle, low intensity (fatigue) loading. Also, recently proposed design equations for lap splices under static loading will permit shorter lap lengths. For these reasons, a study was initiated to investigate the fatigue resistance of reinforced concrete beams with lap splices. A principal variable in this research program was the degree of transverse reinforcement (stirrups) which was provided along the lap splice.</p> <p>The specimens used in this experimental program were seven meters in length, with a cross section 330 mm wide and 508 mm deep, and were reinforced with two No. 30 Grade 400 bars, top and bottom. A lap splice was provided in the bottom tension bars situated in a constant moment region created by a symmetrical two point loading system. The lap splice length and confinement were designed according to ACI Committee 408 recommendations for static loading.</p> <p>Two different lap splice configurations were provided for the test specimens. The first used the maximum number of stirrups that were deemed to be effective for static loading, permitting a shorter lap length. In the second configuration nominal stirrups were provided to the splice at a spacing of one half the effective beam depth, requiring a longer lap length. Failure of the specimens with the heavier stirrups occurred from fatigue of the tensile reinforcing steel and showed similar fatigue resistance to beams containing continuous reinforcement. The specimens with nominal stirrups usually resulted in a splice failure after fewer load cycles, after splitting and delamination of the concrete confining the lap had occurred.</p> <p>Both beams had a similar static bond resistance; however, the beams with the heavier stirrup confinement (shorter lap length) displayed a greater fatigue resistance than the beams with lighter stirrups (longer lap length). These results are in agreement with conclusions reached for seismic loading conditions, which found that splice confinement provided by a high degree of transverse reinforcement is required under cyclic loading to offset the rapid deterioration of the concrete cover confinement.</p>
author2 none
author_facet none
Afseth, Jeffrey G.
author Afseth, Jeffrey G.
author_sort Afseth, Jeffrey G.
title High cycle (fatigue) resistance of reinforced concrete beams with lap splices
title_short High cycle (fatigue) resistance of reinforced concrete beams with lap splices
title_full High cycle (fatigue) resistance of reinforced concrete beams with lap splices
title_fullStr High cycle (fatigue) resistance of reinforced concrete beams with lap splices
title_full_unstemmed High cycle (fatigue) resistance of reinforced concrete beams with lap splices
title_sort high cycle (fatigue) resistance of reinforced concrete beams with lap splices
publisher University of Saskatchewan
publishDate 2013
url http://library.usask.ca/theses/available/etd-01152013-124631/
work_keys_str_mv AT afsethjeffreyg highcyclefatigueresistanceofreinforcedconcretebeamswithlapsplices
_version_ 1716576011206787072