A comparison of helium dilution and plethysmography in measuring static lung volumes
In order to examine the usefulness of the multi breath helium dilution method (MB) it was compared to the single breath helium dilution method (SB) and body plethysmography (BP). Residual volume (RV), total lung capacity (TLC) and vital capacity (VC) were measured in seventeen subjects with obstruct...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
Uppsala universitet, Institutionen för medicinsk biokemi och mikrobiologi
2008
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-9177 |
id |
ndltd-UPSALLA1-oai-DiVA.org-uu-9177 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-uu-91772018-01-14T05:10:13ZA comparison of helium dilution and plethysmography in measuring static lung volumesengGuldbrand, AnnaUppsala universitet, Institutionen för medicinsk biokemi och mikrobiologiUppsala : Universitetsbiblioteket2008static lung volumesmulti breath helium dilutionplethysmographymethod comparisonPhysiologyFysiologiIn order to examine the usefulness of the multi breath helium dilution method (MB) it was compared to the single breath helium dilution method (SB) and body plethysmography (BP). Residual volume (RV), total lung capacity (TLC) and vital capacity (VC) were measured in seventeen subjects with obstructive (11) or restrictive (6) lung disease and four normal subjects. With information from professional literature and current periodicals, advantages and disadvantages with all three methods were compared. ANOVA and Student's t-test were performed on the measurement results. The results of the statistical tests tell us there are differences among the methods in the group of obstructive patients. They also reveal a notable difference between the MB and SB methods when measuring the same parameter. In addition, it was noted that none of the existing sets of prediction equations fulfill the requirements established on high quality lung function testing. Although a thorough evaluation of the reproducibility of the method is still required, it appears to be a viable alternative to body plethysmography. We claim that measuring the above mentioned static lung volumes with only the single breath helium dilution method cannot be considered a satisfactory practice. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-9177application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
static lung volumes multi breath helium dilution plethysmography method comparison Physiology Fysiologi |
spellingShingle |
static lung volumes multi breath helium dilution plethysmography method comparison Physiology Fysiologi Guldbrand, Anna A comparison of helium dilution and plethysmography in measuring static lung volumes |
description |
In order to examine the usefulness of the multi breath helium dilution method (MB) it was compared to the single breath helium dilution method (SB) and body plethysmography (BP). Residual volume (RV), total lung capacity (TLC) and vital capacity (VC) were measured in seventeen subjects with obstructive (11) or restrictive (6) lung disease and four normal subjects. With information from professional literature and current periodicals, advantages and disadvantages with all three methods were compared. ANOVA and Student's t-test were performed on the measurement results. The results of the statistical tests tell us there are differences among the methods in the group of obstructive patients. They also reveal a notable difference between the MB and SB methods when measuring the same parameter. In addition, it was noted that none of the existing sets of prediction equations fulfill the requirements established on high quality lung function testing. Although a thorough evaluation of the reproducibility of the method is still required, it appears to be a viable alternative to body plethysmography. We claim that measuring the above mentioned static lung volumes with only the single breath helium dilution method cannot be considered a satisfactory practice. |
author |
Guldbrand, Anna |
author_facet |
Guldbrand, Anna |
author_sort |
Guldbrand, Anna |
title |
A comparison of helium dilution and plethysmography in measuring static lung volumes |
title_short |
A comparison of helium dilution and plethysmography in measuring static lung volumes |
title_full |
A comparison of helium dilution and plethysmography in measuring static lung volumes |
title_fullStr |
A comparison of helium dilution and plethysmography in measuring static lung volumes |
title_full_unstemmed |
A comparison of helium dilution and plethysmography in measuring static lung volumes |
title_sort |
comparison of helium dilution and plethysmography in measuring static lung volumes |
publisher |
Uppsala universitet, Institutionen för medicinsk biokemi och mikrobiologi |
publishDate |
2008 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-9177 |
work_keys_str_mv |
AT guldbrandanna acomparisonofheliumdilutionandplethysmographyinmeasuringstaticlungvolumes AT guldbrandanna comparisonofheliumdilutionandplethysmographyinmeasuringstaticlungvolumes |
_version_ |
1718609462316498944 |