Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC

This thesis concerns the development and validation of methods for characterization of multi-component preparative LC systems. Measurements of competitive adsorption isotherms are performed to gain detailed information about the interactions inside the chromatography column. This information increas...

Full description

Bibliographic Details
Main Author: Arnell, Robert
Format: Doctoral Thesis
Language:English
Published: Uppsala universitet, Institutionen för ytbioteknik med Centrum för ytbioteknik 2006
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-7422
http://nbn-resolving.de/urn:isbn:91-554-6762-8
id ndltd-UPSALLA1-oai-DiVA.org-uu-7422
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-uu-74222013-01-08T13:04:24ZDevelopment and Validation of Methods for Characterization of Multi-Component Systems in Preparative LCengUtveckling och Validering av Metoder för Karaktärisering av Flerkomponentsystem vid Preparativ VätskekromatografiArnell, RobertUppsala universitet, Institutionen för ytbioteknik med Centrum för ytbioteknikUppsala : Acta Universitatis Upsaliensis2006Analytical chemistryLiquid chromatographyPreparative LCChiral LCMulti-component LCAdsorption isothermTracer-pulse methodInverse methodInverse method on plateausPeak deformationsChiral drug-protein interactionsAnalytisk kemiThis thesis concerns the development and validation of methods for characterization of multi-component preparative LC systems. Measurements of competitive adsorption isotherms are performed to gain detailed information about the interactions inside the chromatography column. This information increases our understanding of the separation process and makes it possible to perform computer simulations and numerical optimizations to find optimal operating conditions. The methods under focus are called “the tracer-pulse method”, “the inverse method”, and “the inverse method on plateaus”. They are extensions of existing methods, with new experimental and numerical procedures to enable rapid and accurate multi-component adsorption isotherm determination. In the validation it was shown that they can produce results agreeing with traditional methods and that the acquired adsorption isotherm parameters can be used in simulations to accurately predict the outcome of preparative LC separations. The methods were used to characterize several complex LC systems and two phenomena were discovered and theoretically treated: 1) The presence of invisible deformed peaks in single-component systems. 2) Peak deformations encountered with modern chiral stationary phases, caused by strongly adsorbed eluent additives. The latter type of deformation was highly tuneable and it was possible to adjust the enantiomer peak shapes so that the peaks tailed in opposite directions with the sharp sides in between, yielding baseline resolution at remarkably high sample loads. In a final applied study both the LC-based perturbation peak method and a biosensor method based on surface plasmon resonance (SPR) were used for the first time for detailed characterization of chiral drug-protein interactions. The fundamental properties of the two very different methods were compared and it was found that the LC method is more suitable for multi-component analysis and that the SPR method is more suitable for stronger interactions. Doctoral thesis, comprehensive summaryinfo:eu-repo/semantics/doctoralThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-7422urn:isbn:91-554-6762-8Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, 1651-6214 ; 256application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Doctoral Thesis
sources NDLTD
topic Analytical chemistry
Liquid chromatography
Preparative LC
Chiral LC
Multi-component LC
Adsorption isotherm
Tracer-pulse method
Inverse method
Inverse method on plateaus
Peak deformations
Chiral drug-protein interactions
Analytisk kemi
spellingShingle Analytical chemistry
Liquid chromatography
Preparative LC
Chiral LC
Multi-component LC
Adsorption isotherm
Tracer-pulse method
Inverse method
Inverse method on plateaus
Peak deformations
Chiral drug-protein interactions
Analytisk kemi
Arnell, Robert
Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC
description This thesis concerns the development and validation of methods for characterization of multi-component preparative LC systems. Measurements of competitive adsorption isotherms are performed to gain detailed information about the interactions inside the chromatography column. This information increases our understanding of the separation process and makes it possible to perform computer simulations and numerical optimizations to find optimal operating conditions. The methods under focus are called “the tracer-pulse method”, “the inverse method”, and “the inverse method on plateaus”. They are extensions of existing methods, with new experimental and numerical procedures to enable rapid and accurate multi-component adsorption isotherm determination. In the validation it was shown that they can produce results agreeing with traditional methods and that the acquired adsorption isotherm parameters can be used in simulations to accurately predict the outcome of preparative LC separations. The methods were used to characterize several complex LC systems and two phenomena were discovered and theoretically treated: 1) The presence of invisible deformed peaks in single-component systems. 2) Peak deformations encountered with modern chiral stationary phases, caused by strongly adsorbed eluent additives. The latter type of deformation was highly tuneable and it was possible to adjust the enantiomer peak shapes so that the peaks tailed in opposite directions with the sharp sides in between, yielding baseline resolution at remarkably high sample loads. In a final applied study both the LC-based perturbation peak method and a biosensor method based on surface plasmon resonance (SPR) were used for the first time for detailed characterization of chiral drug-protein interactions. The fundamental properties of the two very different methods were compared and it was found that the LC method is more suitable for multi-component analysis and that the SPR method is more suitable for stronger interactions.
author Arnell, Robert
author_facet Arnell, Robert
author_sort Arnell, Robert
title Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC
title_short Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC
title_full Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC
title_fullStr Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC
title_full_unstemmed Development and Validation of Methods for Characterization of Multi-Component Systems in Preparative LC
title_sort development and validation of methods for characterization of multi-component systems in preparative lc
publisher Uppsala universitet, Institutionen för ytbioteknik med Centrum för ytbioteknik
publishDate 2006
url http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-7422
http://nbn-resolving.de/urn:isbn:91-554-6762-8
work_keys_str_mv AT arnellrobert developmentandvalidationofmethodsforcharacterizationofmulticomponentsystemsinpreparativelc
AT arnellrobert utvecklingochvalideringavmetoderforkaraktariseringavflerkomponentsystemvidpreparativvatskekromatografi
_version_ 1716508166270746624