Container closure integritytesting with High Voltage LeakDetection

There are various methods that can be used for Container Closure Integrity Testing (CCIT).Each method has its pros and cons.The choice of the CCIT-method depends on various factors such as the material of the primary packaging and product properties. High Voltage Leak Detection(HVLD) is an effective...

Full description

Bibliographic Details
Main Author: Bahnam, Nadeen
Format: Others
Language:English
Published: Uppsala universitet, Nanoteknologi och funktionella material 2021
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439566
id ndltd-UPSALLA1-oai-DiVA.org-uu-439566
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-uu-4395662021-04-09T05:27:57ZContainer closure integritytesting with High Voltage LeakDetectionengBahnam, NadeenUppsala universitet, Nanoteknologi och funktionella material2021Engineering and TechnologyTeknik och teknologierThere are various methods that can be used for Container Closure Integrity Testing (CCIT).Each method has its pros and cons.The choice of the CCIT-method depends on various factors such as the material of the primary packaging and product properties. High Voltage Leak Detection(HVLD) is an effective method. The sensitivity of the method is quite high but its is unclear whether it can detect all the hole sizes that may entails a risk for microbial contamination. The  theoretical calculations and practical experiments shows that HVLD can detect holes in different positions and it can detect holes that are a few micrometers. If HVLD detect hole size that are 5 micrometers, it means that alla sizes that can make risk for microbial contamination for productsmanufacturedonAstraZeneca PET BFS can be detected with HVLD. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439566UPTEC X ; 21 004application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
topic Engineering and Technology
Teknik och teknologier
spellingShingle Engineering and Technology
Teknik och teknologier
Bahnam, Nadeen
Container closure integritytesting with High Voltage LeakDetection
description There are various methods that can be used for Container Closure Integrity Testing (CCIT).Each method has its pros and cons.The choice of the CCIT-method depends on various factors such as the material of the primary packaging and product properties. High Voltage Leak Detection(HVLD) is an effective method. The sensitivity of the method is quite high but its is unclear whether it can detect all the hole sizes that may entails a risk for microbial contamination. The  theoretical calculations and practical experiments shows that HVLD can detect holes in different positions and it can detect holes that are a few micrometers. If HVLD detect hole size that are 5 micrometers, it means that alla sizes that can make risk for microbial contamination for productsmanufacturedonAstraZeneca PET BFS can be detected with HVLD.
author Bahnam, Nadeen
author_facet Bahnam, Nadeen
author_sort Bahnam, Nadeen
title Container closure integritytesting with High Voltage LeakDetection
title_short Container closure integritytesting with High Voltage LeakDetection
title_full Container closure integritytesting with High Voltage LeakDetection
title_fullStr Container closure integritytesting with High Voltage LeakDetection
title_full_unstemmed Container closure integritytesting with High Voltage LeakDetection
title_sort container closure integritytesting with high voltage leakdetection
publisher Uppsala universitet, Nanoteknologi och funktionella material
publishDate 2021
url http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439566
work_keys_str_mv AT bahnamnadeen containerclosureintegritytestingwithhighvoltageleakdetection
_version_ 1719395495368982528