Container closure integritytesting with High Voltage LeakDetection
There are various methods that can be used for Container Closure Integrity Testing (CCIT).Each method has its pros and cons.The choice of the CCIT-method depends on various factors such as the material of the primary packaging and product properties. High Voltage Leak Detection(HVLD) is an effective...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
Uppsala universitet, Nanoteknologi och funktionella material
2021
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439566 |
id |
ndltd-UPSALLA1-oai-DiVA.org-uu-439566 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-uu-4395662021-04-09T05:27:57ZContainer closure integritytesting with High Voltage LeakDetectionengBahnam, NadeenUppsala universitet, Nanoteknologi och funktionella material2021Engineering and TechnologyTeknik och teknologierThere are various methods that can be used for Container Closure Integrity Testing (CCIT).Each method has its pros and cons.The choice of the CCIT-method depends on various factors such as the material of the primary packaging and product properties. High Voltage Leak Detection(HVLD) is an effective method. The sensitivity of the method is quite high but its is unclear whether it can detect all the hole sizes that may entails a risk for microbial contamination. The theoretical calculations and practical experiments shows that HVLD can detect holes in different positions and it can detect holes that are a few micrometers. If HVLD detect hole size that are 5 micrometers, it means that alla sizes that can make risk for microbial contamination for productsmanufacturedonAstraZeneca PET BFS can be detected with HVLD. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439566UPTEC X ; 21 004application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Engineering and Technology Teknik och teknologier |
spellingShingle |
Engineering and Technology Teknik och teknologier Bahnam, Nadeen Container closure integritytesting with High Voltage LeakDetection |
description |
There are various methods that can be used for Container Closure Integrity Testing (CCIT).Each method has its pros and cons.The choice of the CCIT-method depends on various factors such as the material of the primary packaging and product properties. High Voltage Leak Detection(HVLD) is an effective method. The sensitivity of the method is quite high but its is unclear whether it can detect all the hole sizes that may entails a risk for microbial contamination. The theoretical calculations and practical experiments shows that HVLD can detect holes in different positions and it can detect holes that are a few micrometers. If HVLD detect hole size that are 5 micrometers, it means that alla sizes that can make risk for microbial contamination for productsmanufacturedonAstraZeneca PET BFS can be detected with HVLD. |
author |
Bahnam, Nadeen |
author_facet |
Bahnam, Nadeen |
author_sort |
Bahnam, Nadeen |
title |
Container closure integritytesting with High Voltage LeakDetection |
title_short |
Container closure integritytesting with High Voltage LeakDetection |
title_full |
Container closure integritytesting with High Voltage LeakDetection |
title_fullStr |
Container closure integritytesting with High Voltage LeakDetection |
title_full_unstemmed |
Container closure integritytesting with High Voltage LeakDetection |
title_sort |
container closure integritytesting with high voltage leakdetection |
publisher |
Uppsala universitet, Nanoteknologi och funktionella material |
publishDate |
2021 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439566 |
work_keys_str_mv |
AT bahnamnadeen containerclosureintegritytestingwithhighvoltageleakdetection |
_version_ |
1719395495368982528 |