Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time
Introduction: It is recommended to place all the vacuum tubes directly on a sample cradle after vein puncture to prevent analytic error. This recommendation is not always easy to follow because the samples are taken by different professionals under different situations. The three most common analys...
Main Author: | |
---|---|
Format: | Others |
Language: | Swedish |
Published: |
Uppsala universitet, Institutionen för medicinsk biokemi och mikrobiologi
2012
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-182146 |
id |
ndltd-UPSALLA1-oai-DiVA.org-uu-182146 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-uu-1821462013-01-08T13:44:18ZSample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin timesweKarlsson, JessicaUppsala universitet, Institutionen för medicinsk biokemi och mikrobiologi2012vein puncturecoagulationInternational Normalized RatiocitrateEDTAIntroduction: It is recommended to place all the vacuum tubes directly on a sample cradle after vein puncture to prevent analytic error. This recommendation is not always easy to follow because the samples are taken by different professionals under different situations. The three most common analyses, platelets count, haemoglobin and prothrombin time were tested. Therefore, it was interesting to compare results from the three most common analyses with or without sample cradle, to evaluate the influence of this step on the result. Methods: Three analyses were preformed, using blood from 50 different persons. Each person gave two vacuum tubes, each contained 4.5mL of venous blood for the study. Tubes containing EDTA were used for platelet counts and measurement of haemoglobin and tubes containing citrate were used for prothrombin time-analysis. One of the tubes was placed, as recommended, directly on the sample cradle while the other tube was placed flat on a bench for 10 minutes before it was placed on the sample cradle. Results: There was a clear difference in platelet counts with and without immediate cradling but only minor difference between the results for haemoglobin and International Normalized Ratio. Conclusion: Some analyses seem to be more sensitive for variation in cradling than others. For platelet count it was important to immediately rock the tubes but for determination of prothrombine time and hemoglobin it had a small impact. The small impact on the results is probably due to the efficiency of the anticoagulant in the vacuum tubes. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-182146application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
Swedish |
format |
Others
|
sources |
NDLTD |
topic |
vein puncture coagulation International Normalized Ratio citrate EDTA |
spellingShingle |
vein puncture coagulation International Normalized Ratio citrate EDTA Karlsson, Jessica Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
description |
Introduction: It is recommended to place all the vacuum tubes directly on a sample cradle after vein puncture to prevent analytic error. This recommendation is not always easy to follow because the samples are taken by different professionals under different situations. The three most common analyses, platelets count, haemoglobin and prothrombin time were tested. Therefore, it was interesting to compare results from the three most common analyses with or without sample cradle, to evaluate the influence of this step on the result. Methods: Three analyses were preformed, using blood from 50 different persons. Each person gave two vacuum tubes, each contained 4.5mL of venous blood for the study. Tubes containing EDTA were used for platelet counts and measurement of haemoglobin and tubes containing citrate were used for prothrombin time-analysis. One of the tubes was placed, as recommended, directly on the sample cradle while the other tube was placed flat on a bench for 10 minutes before it was placed on the sample cradle. Results: There was a clear difference in platelet counts with and without immediate cradling but only minor difference between the results for haemoglobin and International Normalized Ratio. Conclusion: Some analyses seem to be more sensitive for variation in cradling than others. For platelet count it was important to immediately rock the tubes but for determination of prothrombine time and hemoglobin it had a small impact. The small impact on the results is probably due to the efficiency of the anticoagulant in the vacuum tubes. |
author |
Karlsson, Jessica |
author_facet |
Karlsson, Jessica |
author_sort |
Karlsson, Jessica |
title |
Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
title_short |
Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
title_full |
Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
title_fullStr |
Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
title_full_unstemmed |
Sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
title_sort |
sample cradle prevents pre-analytic error on platelet counts but is not essential for hemoglobin measurement and prothrombin time |
publisher |
Uppsala universitet, Institutionen för medicinsk biokemi och mikrobiologi |
publishDate |
2012 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-182146 |
work_keys_str_mv |
AT karlssonjessica samplecradlepreventspreanalyticerroronplateletcountsbutisnotessentialforhemoglobinmeasurementandprothrombintime |
_version_ |
1716527614060920832 |