Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard
Good power quality is not only determined by uninterruptable power supply, voltage deviations also affect the function of the network and the equipment connected. Electromagnetic disturbances as flicker, harmonics, interharmonics and unbalance are decreasing the power quality. How are the measuremen...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
Uppsala universitet, Institutionen för teknikvetenskaper
2012
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-181193 |
id |
ndltd-UPSALLA1-oai-DiVA.org-uu-181193 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-uu-1811932013-01-08T13:44:16ZPower Quality Analysis of a 110 MW Wind Farm in a 130 kV SwitchyardengNäslund, MyUppsala universitet, Institutionen för teknikvetenskaper2012Power QualityFlickerInterharmonicsHarmonicsUnbalanceWind PowerElkvalitetFlimmerObalansMellantonerÖvertonerVindkraftGood power quality is not only determined by uninterruptable power supply, voltage deviations also affect the function of the network and the equipment connected. Electromagnetic disturbances as flicker, harmonics, interharmonics and unbalance are decreasing the power quality. How are the measurement methods and restrictions stated, to keep the voltagedeviations within reasonable limits and thereby maintaining the networkfunction? Lillgrund wind farm has power quality restrictions set by E.ON Elnät to fulfil in the connection point to the subtransmission network. In addition isa fault ride through requirement set by SVK. All equipment connected tothe network are introducing voltage changes, which can be measured at the point of connection. The scope of the thesis has been to explicitly determine Lillgrund‟s emissions. Three-phase voltage and current measurements have been performed, with measurement systems comprising different bandwidth, to analyse the power quality parameters.Comparisons between standard documentation and technical specifications have been made in order to precise what is considered as good power quality and how it can be measured accurately. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-181193UPTEC ES, 1650-8300 ; 12014application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Power Quality Flicker Interharmonics Harmonics Unbalance Wind Power Elkvalitet Flimmer Obalans Mellantoner Övertoner Vindkraft |
spellingShingle |
Power Quality Flicker Interharmonics Harmonics Unbalance Wind Power Elkvalitet Flimmer Obalans Mellantoner Övertoner Vindkraft Näslund, My Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard |
description |
Good power quality is not only determined by uninterruptable power supply, voltage deviations also affect the function of the network and the equipment connected. Electromagnetic disturbances as flicker, harmonics, interharmonics and unbalance are decreasing the power quality. How are the measurement methods and restrictions stated, to keep the voltagedeviations within reasonable limits and thereby maintaining the networkfunction? Lillgrund wind farm has power quality restrictions set by E.ON Elnät to fulfil in the connection point to the subtransmission network. In addition isa fault ride through requirement set by SVK. All equipment connected tothe network are introducing voltage changes, which can be measured at the point of connection. The scope of the thesis has been to explicitly determine Lillgrund‟s emissions. Three-phase voltage and current measurements have been performed, with measurement systems comprising different bandwidth, to analyse the power quality parameters.Comparisons between standard documentation and technical specifications have been made in order to precise what is considered as good power quality and how it can be measured accurately. |
author |
Näslund, My |
author_facet |
Näslund, My |
author_sort |
Näslund, My |
title |
Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard |
title_short |
Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard |
title_full |
Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard |
title_fullStr |
Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard |
title_full_unstemmed |
Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard |
title_sort |
power quality analysis of a 110 mw wind farm in a 130 kv switchyard |
publisher |
Uppsala universitet, Institutionen för teknikvetenskaper |
publishDate |
2012 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-181193 |
work_keys_str_mv |
AT naslundmy powerqualityanalysisofa110mwwindfarmina130kvswitchyard |
_version_ |
1716527601626906624 |