Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda

This thesis consider alternatives for heating and cooling planned office buildings at Arlanda airport. The thesis is divided into three parts where the third part is a shorter synthesis of the two first. In the first part the energy demands of the buildings are modelled in a computer program. Two di...

Full description

Bibliographic Details
Main Author: Olauson, Jon
Format: Others
Language:Swedish
Published: Uppsala universitet, Institutionen för fysik och astronomi 2008
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-162748
id ndltd-UPSALLA1-oai-DiVA.org-uu-162748
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-uu-1627482013-01-08T13:51:08ZAlternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på ArlandasweHeating and cooling new office buildings at Arlanda airportOlauson, JonUppsala universitet, Institutionen för fysik och astronomi2008This thesis consider alternatives for heating and cooling planned office buildings at Arlanda airport. The thesis is divided into three parts where the third part is a shorter synthesis of the two first. In the first part the energy demands of the buildings are modelled in a computer program. Two different building models are created, one more conventional and one with good energy properties. The results shows that with proper construction and ventilation systems etc. the energy required for heating and cooling could be very low. Whether the consumption will be so low that normal energy installations could be omitted is although hard to predict from the results. The second part of the work concerns different ways of producing the required energy for the buildings. Four energy producing systems (aquifer, rape seed diesel generator, snow-cooling and air blast cooler) are compared with today’s systems (districts heating and compression cooling machines) with respect to environmental impact and economy. District heating and diesel generator with rape seed oil are systems with negative global warming potential, mainly due to the simultaneous production of power together with heat. Compression cooling has the highest GWP and the remaining systems shows a small GWP. Rape seed diesel generator and (in less extent) district heating has a relative large impact on acidification and eutrophication while the other systems have a much smaller impact. Economically the aquifer and air blast cooling are the most competitive systems; the per-kWh price of energy is lower than for today’s systems. Snow cooling also has promising economical potential but the high price on rape seed oil makes the diesel alternative less interesting at the moment. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-162748UPTEC ES, 1650-8300 ; 08011application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language Swedish
format Others
sources NDLTD
description This thesis consider alternatives for heating and cooling planned office buildings at Arlanda airport. The thesis is divided into three parts where the third part is a shorter synthesis of the two first. In the first part the energy demands of the buildings are modelled in a computer program. Two different building models are created, one more conventional and one with good energy properties. The results shows that with proper construction and ventilation systems etc. the energy required for heating and cooling could be very low. Whether the consumption will be so low that normal energy installations could be omitted is although hard to predict from the results. The second part of the work concerns different ways of producing the required energy for the buildings. Four energy producing systems (aquifer, rape seed diesel generator, snow-cooling and air blast cooler) are compared with today’s systems (districts heating and compression cooling machines) with respect to environmental impact and economy. District heating and diesel generator with rape seed oil are systems with negative global warming potential, mainly due to the simultaneous production of power together with heat. Compression cooling has the highest GWP and the remaining systems shows a small GWP. Rape seed diesel generator and (in less extent) district heating has a relative large impact on acidification and eutrophication while the other systems have a much smaller impact. Economically the aquifer and air blast cooling are the most competitive systems; the per-kWh price of energy is lower than for today’s systems. Snow cooling also has promising economical potential but the high price on rape seed oil makes the diesel alternative less interesting at the moment.
author Olauson, Jon
spellingShingle Olauson, Jon
Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda
author_facet Olauson, Jon
author_sort Olauson, Jon
title Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda
title_short Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda
title_full Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda
title_fullStr Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda
title_full_unstemmed Alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på Arlanda
title_sort alternativ för värme- och kylaförsörjning i planerade kontorsbyggnader på arlanda
publisher Uppsala universitet, Institutionen för fysik och astronomi
publishDate 2008
url http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-162748
work_keys_str_mv AT olausonjon alternativforvarmeochkylaforsorjningiplaneradekontorsbyggnaderpaarlanda
AT olausonjon heatingandcoolingnewofficebuildingsatarlandaairport
_version_ 1716530921736241152