Optimization and validation of the method lactose intolerance genotyping with real-time PCR

Abstract Primary lactose intolerance has been associated with a single nucleotide polymorphism located upstream of the lactase gene. The most common diagnostic tests for lactose intolerance are time-consuming and the patient is not allowed to eat and drink for 12 hours before the test is carried out...

Full description

Bibliographic Details
Main Author: Stenberg, Jenny
Format: Others
Language:English
Published: Uppsala universitet 2011
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-150810
id ndltd-UPSALLA1-oai-DiVA.org-uu-150810
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-uu-1508102013-01-08T13:29:52ZOptimization and validation of the method lactose intolerance genotyping with real-time PCRengStenberg, JennyUppsala universitetUppsala universitet, Medicinska och farmaceutiska vetenskapsområdetUppsala universitet, Medicinska fakultetenUppsala universitet, Institutionen för medicinsk biokemi och mikrobiologi2011lactose intolerancesingle nucleotide polymorphismreal-time PCRgenotypeoptimization.Abstract Primary lactose intolerance has been associated with a single nucleotide polymorphism located upstream of the lactase gene. The most common diagnostic tests for lactose intolerance are time-consuming and the patient is not allowed to eat and drink for 12 hours before the test is carried out. A method that can establish the genotype would be an easier way of diagnosing lactose intolerance compared to fenotypic lactose intolerance tests. Optimization and validation of a previously published method was performed with real-time polymerase chain reaction. We used whole blood from de-identified blood donors. During the optimization and validation we used a positive control, genotype C/T from Laboratoriemedicin Västernorrland, Sundsvall. The whole-blood was extracted using the MagNa Pure LC instrument. The reagent used was KAPA PROBE FAST qPCR Master Mix. The optimized program for real-time PCR was established to be 95°C 3min [95°C x 3sec, 55°C x 20sec, detection, 72°C x 15sec] x 50 cycles. Optimal probe concentration was found to be 0.2µM and primer concentration will be 0.5µM. This genotyping method is a good first-stage screening test for lactoseintolerance. Before it can be used as a routine method further validation will be necessary in order to ensure that the evaluation of the results can be done in an easy and secure way.   Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-150810application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
topic lactose intolerance
single nucleotide polymorphism
real-time PCR
genotype
optimization.
spellingShingle lactose intolerance
single nucleotide polymorphism
real-time PCR
genotype
optimization.
Stenberg, Jenny
Optimization and validation of the method lactose intolerance genotyping with real-time PCR
description Abstract Primary lactose intolerance has been associated with a single nucleotide polymorphism located upstream of the lactase gene. The most common diagnostic tests for lactose intolerance are time-consuming and the patient is not allowed to eat and drink for 12 hours before the test is carried out. A method that can establish the genotype would be an easier way of diagnosing lactose intolerance compared to fenotypic lactose intolerance tests. Optimization and validation of a previously published method was performed with real-time polymerase chain reaction. We used whole blood from de-identified blood donors. During the optimization and validation we used a positive control, genotype C/T from Laboratoriemedicin Västernorrland, Sundsvall. The whole-blood was extracted using the MagNa Pure LC instrument. The reagent used was KAPA PROBE FAST qPCR Master Mix. The optimized program for real-time PCR was established to be 95°C 3min [95°C x 3sec, 55°C x 20sec, detection, 72°C x 15sec] x 50 cycles. Optimal probe concentration was found to be 0.2µM and primer concentration will be 0.5µM. This genotyping method is a good first-stage screening test for lactoseintolerance. Before it can be used as a routine method further validation will be necessary in order to ensure that the evaluation of the results can be done in an easy and secure way.  
author Stenberg, Jenny
author_facet Stenberg, Jenny
author_sort Stenberg, Jenny
title Optimization and validation of the method lactose intolerance genotyping with real-time PCR
title_short Optimization and validation of the method lactose intolerance genotyping with real-time PCR
title_full Optimization and validation of the method lactose intolerance genotyping with real-time PCR
title_fullStr Optimization and validation of the method lactose intolerance genotyping with real-time PCR
title_full_unstemmed Optimization and validation of the method lactose intolerance genotyping with real-time PCR
title_sort optimization and validation of the method lactose intolerance genotyping with real-time pcr
publisher Uppsala universitet
publishDate 2011
url http://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-150810
work_keys_str_mv AT stenbergjenny optimizationandvalidationofthemethodlactoseintolerancegenotypingwithrealtimepcr
_version_ 1716522339825352704