Staff dose measurement in real time, an evaluation of Unfors Raysafe i2

Interventional radiology workers job involves exposure to ionizing radiation. In Sweden monitoring the accumulated dose to the personnel in professions, which involves with ionizing radiation, is mandatory. There are many applications that can visualize and measure the accumulated dose of the person...

Full description

Bibliographic Details
Main Author: Khosravinia, Mehdi
Format: Others
Language:English
Published: Umeå universitet, Institutionen för fysik 2013
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-66990
id ndltd-UPSALLA1-oai-DiVA.org-umu-66990
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-umu-669902013-06-04T04:09:43ZStaff dose measurement in real time, an evaluation of Unfors Raysafe i2engKhosravinia, MehdiUmeå universitet, Institutionen för fysik2013Unfors Raysafe i2Interventional radiology workers job involves exposure to ionizing radiation. In Sweden monitoring the accumulated dose to the personnel in professions, which involves with ionizing radiation, is mandatory. There are many applications that can visualize and measure the accumulated dose of the personnel.  The DoseAware system is distributed commercially by Philips. This device is mainly developed, designed and made by Unfors Instrument AB in Gothenburg, Sweden with a commercial name Unfors Raysafe i2. It is real time dose visualizer system which uses mostly to increases personnel’s awareness.   This system consists of a number of PDM(personnel dose meters) which detects radiation, and transfers it wirelessly to a monitor that can visualize dose rate. Transferred Data will be analyzed by two softwares, the Dose manager and the DoseView.   This study concerns about Unfors Raysafe i2's functionality, performance and usability of this system as a dosimeter for the staff of an interventional radiology lab. To examine differences to other systems and to validate it against traditional TLD measurement.   The aim of the project is to control how to use the system for training of personnel working in environments with ionizing radiation. The more specific aim is to investigate if it is possible to reduce the accumulated dose by using the device during an interventional procedure.   In this study, the dose aware system was installed At IR-lab of Umeå hospital. The first measurement session was a blind measurement, i.e. the personnel were not able to see their dose. Prior to the second measurement some hints was given them and explanations about working radiation hygiene and after that another measurement session was held, called an ‘’open measurement’’ when they could see the Dose aware system’s monitor that displayed their individual doses.   Comparison between acquired results from both weeks shows a decrease in accumulated dose to the radiologist by almost 20 % (using the workflow ratio between week 1 and 2 as a normalizing factor).   Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-66990application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
topic Unfors Raysafe i2
spellingShingle Unfors Raysafe i2
Khosravinia, Mehdi
Staff dose measurement in real time, an evaluation of Unfors Raysafe i2
description Interventional radiology workers job involves exposure to ionizing radiation. In Sweden monitoring the accumulated dose to the personnel in professions, which involves with ionizing radiation, is mandatory. There are many applications that can visualize and measure the accumulated dose of the personnel.  The DoseAware system is distributed commercially by Philips. This device is mainly developed, designed and made by Unfors Instrument AB in Gothenburg, Sweden with a commercial name Unfors Raysafe i2. It is real time dose visualizer system which uses mostly to increases personnel’s awareness.   This system consists of a number of PDM(personnel dose meters) which detects radiation, and transfers it wirelessly to a monitor that can visualize dose rate. Transferred Data will be analyzed by two softwares, the Dose manager and the DoseView.   This study concerns about Unfors Raysafe i2's functionality, performance and usability of this system as a dosimeter for the staff of an interventional radiology lab. To examine differences to other systems and to validate it against traditional TLD measurement.   The aim of the project is to control how to use the system for training of personnel working in environments with ionizing radiation. The more specific aim is to investigate if it is possible to reduce the accumulated dose by using the device during an interventional procedure.   In this study, the dose aware system was installed At IR-lab of Umeå hospital. The first measurement session was a blind measurement, i.e. the personnel were not able to see their dose. Prior to the second measurement some hints was given them and explanations about working radiation hygiene and after that another measurement session was held, called an ‘’open measurement’’ when they could see the Dose aware system’s monitor that displayed their individual doses.   Comparison between acquired results from both weeks shows a decrease in accumulated dose to the radiologist by almost 20 % (using the workflow ratio between week 1 and 2 as a normalizing factor).  
author Khosravinia, Mehdi
author_facet Khosravinia, Mehdi
author_sort Khosravinia, Mehdi
title Staff dose measurement in real time, an evaluation of Unfors Raysafe i2
title_short Staff dose measurement in real time, an evaluation of Unfors Raysafe i2
title_full Staff dose measurement in real time, an evaluation of Unfors Raysafe i2
title_fullStr Staff dose measurement in real time, an evaluation of Unfors Raysafe i2
title_full_unstemmed Staff dose measurement in real time, an evaluation of Unfors Raysafe i2
title_sort staff dose measurement in real time, an evaluation of unfors raysafe i2
publisher Umeå universitet, Institutionen för fysik
publishDate 2013
url http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-66990
work_keys_str_mv AT khosraviniamehdi staffdosemeasurementinrealtimeanevaluationofunforsraysafei2
_version_ 1716586612228358144