Classification of spectral signatures in biological aerosols

In this thesis multivariate methods were used to evaluate pretreatment methods, such as normalization, as well as classification possibilities of data collected with Laser Induced Breakdown Spectroscopy (LIBS). The LIBS system that FOI is currently developing for the purpose of classifying biologica...

Full description

Bibliographic Details
Main Author: Andersson, Henrik
Format: Others
Language:English
Published: Umeå universitet, Institutionen för fysik 2013
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-64002
id ndltd-UPSALLA1-oai-DiVA.org-umu-64002
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-umu-640022013-01-19T15:47:44ZClassification of spectral signatures in biological aerosolsengAndersson, HenrikUmeå universitet, Institutionen för fysik2013In this thesis multivariate methods were used to evaluate pretreatment methods, such as normalization, as well as classification possibilities of data collected with Laser Induced Breakdown Spectroscopy (LIBS). The LIBS system that FOI is currently developing for the purpose of classifying biological airborne threats was used to collect data from ten different samples in a laboratory environment. Principal component analysis (PCA) shows that it is possible to observe differences between samples using the two types of data acquired from the LIBS system, i.e., 2D CCD camera images and 1D spectra extracted from the image. Further results using partial least squares discriminant analysis (PLS-DA) show that normalization of the data only has visual effects in the PCA score-plots and do not affect the models predictability. Results also show that cropping and binning the pixels in the image is possible to some extent without losing significant predictability. I det här examensarbetet har multivariat dataanalys använts för att utvärdera förbehandlings-metoder, t.ex. normalisering, och klassificeringsmöjligheter för spektralt data insamlat med Laser Induced Breakdown Spectroscopy (LIBS). Systemet som FOI utvecklat under de senaste åren i syfte att analysera enstaka partiklar i luft har använts i laboratoriemiljö för att samla data från tio olika prover. En principalkomponentanalys (PCA) visar att det går att se skillnader mellan proverna utifrån de två datatyperna som erhålls från LIBS, 2D CCD bilder och spektra extraherat från dessa bilder. Vidare så visar resultat från partiell minstakvadrat-diskriminantanalys (PLS-DA) att normalisering av data endast har en visuell effekt i PCA score-plottar och inte har någon inverkan på modellernas prediktionsfömåga. Resultat visar även på möjligheter att beskära och binna pixlar i bilderna i viss utstreckning utan att förlora signifikant prediktionsförmåga. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-64002application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
description In this thesis multivariate methods were used to evaluate pretreatment methods, such as normalization, as well as classification possibilities of data collected with Laser Induced Breakdown Spectroscopy (LIBS). The LIBS system that FOI is currently developing for the purpose of classifying biological airborne threats was used to collect data from ten different samples in a laboratory environment. Principal component analysis (PCA) shows that it is possible to observe differences between samples using the two types of data acquired from the LIBS system, i.e., 2D CCD camera images and 1D spectra extracted from the image. Further results using partial least squares discriminant analysis (PLS-DA) show that normalization of the data only has visual effects in the PCA score-plots and do not affect the models predictability. Results also show that cropping and binning the pixels in the image is possible to some extent without losing significant predictability. === I det här examensarbetet har multivariat dataanalys använts för att utvärdera förbehandlings-metoder, t.ex. normalisering, och klassificeringsmöjligheter för spektralt data insamlat med Laser Induced Breakdown Spectroscopy (LIBS). Systemet som FOI utvecklat under de senaste åren i syfte att analysera enstaka partiklar i luft har använts i laboratoriemiljö för att samla data från tio olika prover. En principalkomponentanalys (PCA) visar att det går att se skillnader mellan proverna utifrån de två datatyperna som erhålls från LIBS, 2D CCD bilder och spektra extraherat från dessa bilder. Vidare så visar resultat från partiell minstakvadrat-diskriminantanalys (PLS-DA) att normalisering av data endast har en visuell effekt i PCA score-plottar och inte har någon inverkan på modellernas prediktionsfömåga. Resultat visar även på möjligheter att beskära och binna pixlar i bilderna i viss utstreckning utan att förlora signifikant prediktionsförmåga.
author Andersson, Henrik
spellingShingle Andersson, Henrik
Classification of spectral signatures in biological aerosols
author_facet Andersson, Henrik
author_sort Andersson, Henrik
title Classification of spectral signatures in biological aerosols
title_short Classification of spectral signatures in biological aerosols
title_full Classification of spectral signatures in biological aerosols
title_fullStr Classification of spectral signatures in biological aerosols
title_full_unstemmed Classification of spectral signatures in biological aerosols
title_sort classification of spectral signatures in biological aerosols
publisher Umeå universitet, Institutionen för fysik
publishDate 2013
url http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-64002
work_keys_str_mv AT anderssonhenrik classificationofspectralsignaturesinbiologicalaerosols
_version_ 1716575961551470592