Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus

The European parliament has, during recent years, continuously updated their energy efficient requirements and directives underlining how much energy a building may use. Since the building sector accounts for such a large amount of the total energy use in Sweden, it’s important to make it more effic...

Full description

Bibliographic Details
Main Author: Bergwaahl, Johannes
Format: Others
Language:Swedish
Published: Umeå universitet, Institutionen för tillämpad fysik och elektronik 2016
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-121877
id ndltd-UPSALLA1-oai-DiVA.org-umu-121877
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-umu-1218772016-06-11T05:01:40ZOrsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshussweReasons for difference between calculated and measured energy use in apartment buildingsBergwaahl, JohannesUmeå universitet, Institutionen för tillämpad fysik och elektronik2016Energibyggnadnyckeltalstandardiserad indataindata energiberäkningarrekommenderat indataThe European parliament has, during recent years, continuously updated their energy efficient requirements and directives underlining how much energy a building may use. Since the building sector accounts for such a large amount of the total energy use in Sweden, it’s important to make it more efficient. During a building’s planning phase, the energy use must be calculated in order to see whether the building will meet the building codes set by the Swedish National Board of Housing, Building and Planning. Unfortunately, it is very common that the actual use differs from the calculated, because of uncertainties in the input data. In this master thesis, input data that is used in energy calculations for apartment buildings has been studied. This has been performed thoroughly through a literature study and via computer simulations in which an apartment building is simulated using IDA ICE. Lastly, a sensitivity analysis was performed where the effect from variations in the input data was compiled. The results show that variations in hot-water use, indoor temperature and hot-water circulation losses also assumptions about thermal bridges and buildings mechanical systems can have significant impact on a building’s energy use. For new smaller apartment buildings the energy loss from hot-water circulation can amount to much higher than what is recommended as input data. Therefore, it is important to use as little standardized input data as possible to reduce the uncertainties. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-121877application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language Swedish
format Others
sources NDLTD
topic Energi
byggnad
nyckeltal
standardiserad indata
indata energiberäkningar
rekommenderat indata
spellingShingle Energi
byggnad
nyckeltal
standardiserad indata
indata energiberäkningar
rekommenderat indata
Bergwaahl, Johannes
Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
description The European parliament has, during recent years, continuously updated their energy efficient requirements and directives underlining how much energy a building may use. Since the building sector accounts for such a large amount of the total energy use in Sweden, it’s important to make it more efficient. During a building’s planning phase, the energy use must be calculated in order to see whether the building will meet the building codes set by the Swedish National Board of Housing, Building and Planning. Unfortunately, it is very common that the actual use differs from the calculated, because of uncertainties in the input data. In this master thesis, input data that is used in energy calculations for apartment buildings has been studied. This has been performed thoroughly through a literature study and via computer simulations in which an apartment building is simulated using IDA ICE. Lastly, a sensitivity analysis was performed where the effect from variations in the input data was compiled. The results show that variations in hot-water use, indoor temperature and hot-water circulation losses also assumptions about thermal bridges and buildings mechanical systems can have significant impact on a building’s energy use. For new smaller apartment buildings the energy loss from hot-water circulation can amount to much higher than what is recommended as input data. Therefore, it is important to use as little standardized input data as possible to reduce the uncertainties.
author Bergwaahl, Johannes
author_facet Bergwaahl, Johannes
author_sort Bergwaahl, Johannes
title Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
title_short Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
title_full Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
title_fullStr Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
title_full_unstemmed Orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
title_sort orsaker till differens mellan beräknad och uppmätt energianvändning för flerbostadshus
publisher Umeå universitet, Institutionen för tillämpad fysik och elektronik
publishDate 2016
url http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-121877
work_keys_str_mv AT bergwaahljohannes orsakertilldifferensmellanberaknadochuppmattenergianvandningforflerbostadshus
AT bergwaahljohannes reasonsfordifferencebetweencalculatedandmeasuredenergyuseinapartmentbuildings
_version_ 1718301656570920960