Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction

Hybrid positron emission tomography/magnetic resonance imaging (PET/MR) scanners are one of the latest tools available in the field of medical imaging, and are expected to outperform the well-established PET/X-ray computed tomography (CT) scanners in a large range of fields. The perhaps largest chal...

Full description

Bibliographic Details
Main Author: Aasheim, Lars Birger
Format: Others
Language:English
Published: Norges teknisk-naturvitenskapelige universitet, Institutt for fysikk 2014
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:no:ntnu:diva-26367
id ndltd-UPSALLA1-oai-DiVA.org-ntnu-26367
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-ntnu-263672014-09-15T04:46:41ZAttenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correctionengAasheim, Lars BirgerNorges teknisk-naturvitenskapelige universitet, Institutt for fysikkInstitutt for fysikk2014Hybrid positron emission tomography/magnetic resonance imaging (PET/MR) scanners are one of the latest tools available in the field of medical imaging, and are expected to outperform the well-established PET/X-ray computed tomography (CT) scanners in a large range of fields. The perhaps largest challenge that has to be overcome before this can be achieved, is that of attenuation correction (AC) of the acquired PET images, as there is no direct relation between the MR image intensity of a tissue and its attenuating properties, as is the case in CT.This study investigated the performance of two PET AC methods provided with the biograph mMR PET/MR scanner installed at St. Olavs Hospital (Trondheim, Norway); one for head imaging based on an ultra-short echo-time (UTE) sequence, and one for whole-body imaging based on a Dixon sequence. These AC methods were compared to the `gold standard' of CT-based AC, based on activity concentrations in PET images from mMR examinations of lymphoma and lung cancer patients, corrected with the different AC methods (UTE, Dixon and CT).The results of the study show that the UTE-based AC method leads to an underestimation of PET activity in the brain of up to 9 \% in the investigated regions of interest. This is caused by underestimation of bone in the cranial region. The exclusion of bone in the Dixon-based AC method leads to underestimation of PET activity in the thorax/abdomen, indicated by an underestimation of 4 \% in the liver. The two MR-based AC methods are thus not sufficiently accurate to be utilised for quantification in PET imaging. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:no:ntnu:diva-26367Local ntnudaim:11328application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
description Hybrid positron emission tomography/magnetic resonance imaging (PET/MR) scanners are one of the latest tools available in the field of medical imaging, and are expected to outperform the well-established PET/X-ray computed tomography (CT) scanners in a large range of fields. The perhaps largest challenge that has to be overcome before this can be achieved, is that of attenuation correction (AC) of the acquired PET images, as there is no direct relation between the MR image intensity of a tissue and its attenuating properties, as is the case in CT.This study investigated the performance of two PET AC methods provided with the biograph mMR PET/MR scanner installed at St. Olavs Hospital (Trondheim, Norway); one for head imaging based on an ultra-short echo-time (UTE) sequence, and one for whole-body imaging based on a Dixon sequence. These AC methods were compared to the `gold standard' of CT-based AC, based on activity concentrations in PET images from mMR examinations of lymphoma and lung cancer patients, corrected with the different AC methods (UTE, Dixon and CT).The results of the study show that the UTE-based AC method leads to an underestimation of PET activity in the brain of up to 9 \% in the investigated regions of interest. This is caused by underestimation of bone in the cranial region. The exclusion of bone in the Dixon-based AC method leads to underestimation of PET activity in the thorax/abdomen, indicated by an underestimation of 4 \% in the liver. The two MR-based AC methods are thus not sufficiently accurate to be utilised for quantification in PET imaging.
author Aasheim, Lars Birger
spellingShingle Aasheim, Lars Birger
Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction
author_facet Aasheim, Lars Birger
author_sort Aasheim, Lars Birger
title Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction
title_short Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction
title_full Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction
title_fullStr Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction
title_full_unstemmed Attenuation correction in PET/MR : A performance assessment of UTE-based and Dixon-based methods for PET attenuation correction
title_sort attenuation correction in pet/mr : a performance assessment of ute-based and dixon-based methods for pet attenuation correction
publisher Norges teknisk-naturvitenskapelige universitet, Institutt for fysikk
publishDate 2014
url http://urn.kb.se/resolve?urn=urn:nbn:no:ntnu:diva-26367
work_keys_str_mv AT aasheimlarsbirger attenuationcorrectioninpetmraperformanceassessmentofutebasedanddixonbasedmethodsforpetattenuationcorrection
_version_ 1716714350599733248