Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?

From a fire perspective EPS insulation has characteristics that makes it inflammable and can cause fast fire spread which is aggravating for the fire and rescue services. Reports from fire and rescue operations related to both EPS insulation and construction sites of buildings, show that fires most...

Full description

Bibliographic Details
Main Author: Lindholm, Lars
Format: Others
Language:Swedish
Published: Mälardalens högskola, Akademin för ekonomi, samhälle och teknik 2015
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-28459
id ndltd-UPSALLA1-oai-DiVA.org-mdh-28459
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-mdh-284592015-08-18T04:53:47ZCellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?sweLindholm, LarsMälardalens högskola, Akademin för ekonomi, samhälle och teknik2015eps insulationcombustiblefaçadefire safetyfire and rescuecellplastisoleringfasadisoleringräddningstjänstFrom a fire perspective EPS insulation has characteristics that makes it inflammable and can cause fast fire spread which is aggravating for the fire and rescue services. Reports from fire and rescue operations related to both EPS insulation and construction sites of buildings, show that fires most often are related to faults in protecting combustible materials during hot works such as welding. A case study was performed with the purpose to investigate flaws during handling and installation of EPS insulation at four construction sites. The project consisted of field studies with interviews with respective site managers and a supplier of façade systems. Interviews were also conducted with the fire and rescue services to obtain a deeper understanding for the problems of fire rescue operations during fires with large quantities of EPS insulation and the risks from using combustible insulation in modern building technology. The study showed that fire safety measurements were not taken during handling and installation of EPS insulation in particular. EPS insulation was only looked at from an economical perspective which resulted in large quantities of insulation stored at the construction sites and in scaffolds prior to installation. It was concluded that handling and installation of EPS insulation was inadequate from a construction site fire safety point of view. Furthermore irregularities and lack of thoroughly made inspections of insulation of façade installations show that there are a lot of uncertainty regarding the fire safety of a façade with combustible insulation. Suggestions to limit fires in combustible insulations, increase quality of the construction of facades as well as raise awareness of fire hazards during planning and construction of buildings were made. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-28459application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language Swedish
format Others
sources NDLTD
topic eps insulation
combustible
façade
fire safety
fire and rescue
cellplastisolering
fasadisolering
räddningstjänst
spellingShingle eps insulation
combustible
façade
fire safety
fire and rescue
cellplastisolering
fasadisolering
räddningstjänst
Lindholm, Lars
Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?
description From a fire perspective EPS insulation has characteristics that makes it inflammable and can cause fast fire spread which is aggravating for the fire and rescue services. Reports from fire and rescue operations related to both EPS insulation and construction sites of buildings, show that fires most often are related to faults in protecting combustible materials during hot works such as welding. A case study was performed with the purpose to investigate flaws during handling and installation of EPS insulation at four construction sites. The project consisted of field studies with interviews with respective site managers and a supplier of façade systems. Interviews were also conducted with the fire and rescue services to obtain a deeper understanding for the problems of fire rescue operations during fires with large quantities of EPS insulation and the risks from using combustible insulation in modern building technology. The study showed that fire safety measurements were not taken during handling and installation of EPS insulation in particular. EPS insulation was only looked at from an economical perspective which resulted in large quantities of insulation stored at the construction sites and in scaffolds prior to installation. It was concluded that handling and installation of EPS insulation was inadequate from a construction site fire safety point of view. Furthermore irregularities and lack of thoroughly made inspections of insulation of façade installations show that there are a lot of uncertainty regarding the fire safety of a façade with combustible insulation. Suggestions to limit fires in combustible insulations, increase quality of the construction of facades as well as raise awareness of fire hazards during planning and construction of buildings were made.
author Lindholm, Lars
author_facet Lindholm, Lars
author_sort Lindholm, Lars
title Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?
title_short Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?
title_full Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?
title_fullStr Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?
title_full_unstemmed Cellplastisolering i fasader : Kan kostnadseffektivitet och brandsäkerhet kombineras?
title_sort cellplastisolering i fasader : kan kostnadseffektivitet och brandsäkerhet kombineras?
publisher Mälardalens högskola, Akademin för ekonomi, samhälle och teknik
publishDate 2015
url http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-28459
work_keys_str_mv AT lindholmlars cellplastisoleringifasaderkankostnadseffektivitetochbrandsakerhetkombineras
_version_ 1716817228054134784