In April 2007 we contacted Lennart Augustsson at Designpartners AB in Västerås. He came up with the idea to investigate and evaluate their construction of a interaction beam, CSB-beam. CSB is short for Connector Interaction beam. The beam is based on a horizontal C-profile of high-tensile steel and...

Full description

Bibliographic Details
Main Authors: Lindgren, Erik, Hedström, Jim
Format: Others
Language:Swedish
Published: Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling 2007
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-1437
id ndltd-UPSALLA1-oai-DiVA.org-mdh-1437
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-mdh-14372013-01-08T13:47:48ZSAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector SamverkansbalksweLindgren, ErikHedström, JimMälardalens högskola, Akademin för hållbar samhälls- och teknikutvecklingMälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling2007CollaborationsteelconcreteblockanchorsbeamcalculationstestsIn April 2007 we contacted Lennart Augustsson at Designpartners AB in Västerås. He came up with the idea to investigate and evaluate their construction of a interaction beam, CSB-beam. CSB is short for Connector Interaction beam. The beam is based on a horizontal C-profile of high-tensile steel and in the bottom of the profile are vertical flat bar welded so called block connectors. These block anchorsare also made of hightensilesteel. Their task is to create collaboration between the steel and the concrete. The dimensioning of the block connectors is done according to the Swedish standard SSENV199411.The purpose of this study is to evaluate and control the formula used for the dimensioning which is found in SS-ENV 1994-1-1.There has been two main parts of this exam work. Part 1: Theoretical preliminary investigations,consisting of calculations and literature studies of block anchors. Part 2: Practical testloads of four prefabricatedCSB-beams.The results of the two parts were thencompared to see if theory corresponded to reality. The result shows that the comparison of the formula in Swedish standard, SS-ENV 1994-1-1 can be used for dimensioning of block connectors in interaction beams. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:mdh:diva-1437application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language Swedish
format Others
sources NDLTD
topic Collaboration
steel
concrete
blockanchors
beam
calculations
tests
spellingShingle Collaboration
steel
concrete
blockanchors
beam
calculations
tests
Lindgren, Erik
Hedström, Jim
SAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector Samverkansbalk
description In April 2007 we contacted Lennart Augustsson at Designpartners AB in Västerås. He came up with the idea to investigate and evaluate their construction of a interaction beam, CSB-beam. CSB is short for Connector Interaction beam. The beam is based on a horizontal C-profile of high-tensile steel and in the bottom of the profile are vertical flat bar welded so called block connectors. These block anchorsare also made of hightensilesteel. Their task is to create collaboration between the steel and the concrete. The dimensioning of the block connectors is done according to the Swedish standard SSENV199411.The purpose of this study is to evaluate and control the formula used for the dimensioning which is found in SS-ENV 1994-1-1.There has been two main parts of this exam work. Part 1: Theoretical preliminary investigations,consisting of calculations and literature studies of block anchors. Part 2: Practical testloads of four prefabricatedCSB-beams.The results of the two parts were thencompared to see if theory corresponded to reality. The result shows that the comparison of the formula in Swedish standard, SS-ENV 1994-1-1 can be used for dimensioning of block connectors in interaction beams.
author Lindgren, Erik
Hedström, Jim
author_facet Lindgren, Erik
Hedström, Jim
author_sort Lindgren, Erik
title SAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector Samverkansbalk
title_short SAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector Samverkansbalk
title_full SAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector Samverkansbalk
title_fullStr SAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector Samverkansbalk
title_full_unstemmed SAMVERKAN STÅL/BETONG : Kontroll av kapacitet hos blockankare i Connector Samverkansbalk
title_sort samverkan stål/betong : kontroll av kapacitet hos blockankare i connector samverkansbalk
publisher Mälardalens högskola, Akademin för hållbar samhälls- och teknikutveckling