Aim: The aim of this study is to investigate if biaxial flexural strength for pressed glass ceramic with glazed, polished and grinded surface is affected by the acidic beverages Coca Cola and red wine. Material and method: 63 specimens were manufactured in IPS e.max Press®, divided into 6 test group...

Full description

Bibliographic Details
Main Authors: Bromé, Nathalie, Jonung, Lina
Format: Others
Language:Swedish
Published: Malmö universitet, Odontologiska fakulteten (OD) 2021
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-42753
id ndltd-UPSALLA1-oai-DiVA.org-mau-42753
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-mau-427532021-09-18T05:25:06ZSura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytorsweBiaxial flexural strength on lithium disilicate based glass ceramic with different surface submerged in acidic beveragesBromé, NathalieJonung, LinaMalmö universitet, Odontologiska fakulteten (OD)2021Flexural strengthBeverageGlass ceramicThermocyclingSurface treatmentBöjhållfasthetDryckGlaskeramTermocyklingYtbehandlingDentistryOdontologiAim: The aim of this study is to investigate if biaxial flexural strength for pressed glass ceramic with glazed, polished and grinded surface is affected by the acidic beverages Coca Cola and red wine. Material and method: 63 specimens were manufactured in IPS e.max Press®, divided into 6 test groups and one control group (KG) with 9 specimens in each group, in the dimensions 12 mm in diameter and in thickness, 1,8 mm without notch and 2,2 mm with notch. The specimens subdivided by different surface treatments; glazed surface (CCG, RVG), polished surface (CCP, RVP) and ground surface (CCS, RVS). Three groups underwent thermocycling for 970 cycles in 8°C Coca Cola® and three groups red wine at room temperature. Results: The results show significant difference between the groups with α=0,001. Biaxial flexural strength test showed that the CCS group had the highest mean value (340 MPa) and CCP the lowest mean value (214 MPa). CCS showed significant differences to all groups except RVP and RVS. Furthermore the RVP group showed no significant difference to any other group and RVS only towards CCP. Conclusion: Within the limitations of this in vitro study the following conclusions can be made; Acidic beverages do not affect the flexural strength for pressed lithium disilicate based glass ceramics. The flexural strength is affected by surface treatment, where grinding with sandpaper results in higher flexural strength. Syfte: Syftet med föreliggande studie är att undersöka om den biaxiala böjhållfastheten på litiumdisilikatbaserad glaskeram som framställts genom pressteknik med tre olika ytbehandlingar (glansbränd yta eller för att efterlikna ocklusal inslipning eller abraderat slitage) påverkas av de sura dryckerna Coca Cola® och rödvin.Material och metod: 63 provkroppar tillverkades av IPS e.max Press®. Provkropparna delades in i 6 testgrupper, och en kontrollgrupp (KG), á 9 i varje, med måtten 12 mm i diameter och tjocklek 1,8 mm utan notch och 2,2 mm med notch. Provkropparna delades in utifrån olika ytbehandlingar, glansbränd (CCG, RVG), polerad (CCP, RVP) och slipad med sandpapper (CCS, RVS). 3 grupper genomgick termocykling i 970 cykler i 8°C Coca Cola®, och 3 grupper i rödvin i rumstemperatur, varvat med destillerat vatten i 37°C. Därefter utfördes biaxialt böjhållfasthetstest och resultaten analyserades med One-way ANOVA, Tukey’s test, signifikansnivå α= 0,05.Resultat: Resultaten visar att det finns signifikant skillnad mellan grupperna α=0,001. Det biaxiala böjhållfasthetstestet påvisade att gruppen CCS hade högst medelvärde (340 MPa) och CCP hade lägst medelvärde (214 MPa). CCS visade signifikant skillnad jämfört med samtliga grupper, förutom RVP och RVS. Vidare uppvisade RVP ingen signifikant skillnad jämfört med någon av de övriga grupperna och RVS endast mot CCP.Slutsats: Inom denna in vitro-studies begränsningar kan följande slutsatser dras; Sura drycker påverkar inte böjhållfastheten på litiumdisilikatbaserad glaskeram som framställts genom pressteknik. Hållfastheten påverkas beroende på ytbehandling. Genom att slipa ytan med slippapper resulterade det i högre biaxial böjhållfasthet. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-42753application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language Swedish
format Others
sources NDLTD
topic Flexural strength
Beverage
Glass ceramic
Thermocycling
Surface treatment
Böjhållfasthet
Dryck
Glaskeram
Termocykling
Ytbehandling
Dentistry
Odontologi
spellingShingle Flexural strength
Beverage
Glass ceramic
Thermocycling
Surface treatment
Böjhållfasthet
Dryck
Glaskeram
Termocykling
Ytbehandling
Dentistry
Odontologi
Bromé, Nathalie
Jonung, Lina
Sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
description Aim: The aim of this study is to investigate if biaxial flexural strength for pressed glass ceramic with glazed, polished and grinded surface is affected by the acidic beverages Coca Cola and red wine. Material and method: 63 specimens were manufactured in IPS e.max Press®, divided into 6 test groups and one control group (KG) with 9 specimens in each group, in the dimensions 12 mm in diameter and in thickness, 1,8 mm without notch and 2,2 mm with notch. The specimens subdivided by different surface treatments; glazed surface (CCG, RVG), polished surface (CCP, RVP) and ground surface (CCS, RVS). Three groups underwent thermocycling for 970 cycles in 8°C Coca Cola® and three groups red wine at room temperature. Results: The results show significant difference between the groups with α=0,001. Biaxial flexural strength test showed that the CCS group had the highest mean value (340 MPa) and CCP the lowest mean value (214 MPa). CCS showed significant differences to all groups except RVP and RVS. Furthermore the RVP group showed no significant difference to any other group and RVS only towards CCP. Conclusion: Within the limitations of this in vitro study the following conclusions can be made; Acidic beverages do not affect the flexural strength for pressed lithium disilicate based glass ceramics. The flexural strength is affected by surface treatment, where grinding with sandpaper results in higher flexural strength. === Syfte: Syftet med föreliggande studie är att undersöka om den biaxiala böjhållfastheten på litiumdisilikatbaserad glaskeram som framställts genom pressteknik med tre olika ytbehandlingar (glansbränd yta eller för att efterlikna ocklusal inslipning eller abraderat slitage) påverkas av de sura dryckerna Coca Cola® och rödvin.Material och metod: 63 provkroppar tillverkades av IPS e.max Press®. Provkropparna delades in i 6 testgrupper, och en kontrollgrupp (KG), á 9 i varje, med måtten 12 mm i diameter och tjocklek 1,8 mm utan notch och 2,2 mm med notch. Provkropparna delades in utifrån olika ytbehandlingar, glansbränd (CCG, RVG), polerad (CCP, RVP) och slipad med sandpapper (CCS, RVS). 3 grupper genomgick termocykling i 970 cykler i 8°C Coca Cola®, och 3 grupper i rödvin i rumstemperatur, varvat med destillerat vatten i 37°C. Därefter utfördes biaxialt böjhållfasthetstest och resultaten analyserades med One-way ANOVA, Tukey’s test, signifikansnivå α= 0,05.Resultat: Resultaten visar att det finns signifikant skillnad mellan grupperna α=0,001. Det biaxiala böjhållfasthetstestet påvisade att gruppen CCS hade högst medelvärde (340 MPa) och CCP hade lägst medelvärde (214 MPa). CCS visade signifikant skillnad jämfört med samtliga grupper, förutom RVP och RVS. Vidare uppvisade RVP ingen signifikant skillnad jämfört med någon av de övriga grupperna och RVS endast mot CCP.Slutsats: Inom denna in vitro-studies begränsningar kan följande slutsatser dras; Sura drycker påverkar inte böjhållfastheten på litiumdisilikatbaserad glaskeram som framställts genom pressteknik. Hållfastheten påverkas beroende på ytbehandling. Genom att slipa ytan med slippapper resulterade det i högre biaxial böjhållfasthet.
author Bromé, Nathalie
Jonung, Lina
author_facet Bromé, Nathalie
Jonung, Lina
author_sort Bromé, Nathalie
title Sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
title_short Sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
title_full Sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
title_fullStr Sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
title_full_unstemmed Sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
title_sort sura dryckers påverkan på biaxial böjhållfasthet på litiumdisilkatbaserad glaskeram med olika ytor
publisher Malmö universitet, Odontologiska fakulteten (OD)
publishDate 2021
url http://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-42753
work_keys_str_mv AT bromenathalie suradryckerspaverkanpabiaxialbojhallfasthetpalitiumdisilkatbaseradglaskerammedolikaytor
AT jonunglina suradryckerspaverkanpabiaxialbojhallfasthetpalitiumdisilkatbaseradglaskerammedolikaytor
AT bromenathalie biaxialflexuralstrengthonlithiumdisilicatebasedglassceramicwithdifferentsurfacesubmergedinacidicbeverages
AT jonunglina biaxialflexuralstrengthonlithiumdisilicatebasedglassceramicwithdifferentsurfacesubmergedinacidicbeverages
_version_ 1719481349553782784