Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network
Monitoring and logging is fundamental in systems. Today, these techniques are widely used to detect functionality issues as well as malicious event. This thesis compares and evaluates two techniques commonly used for this purpose: the Simple Network Management Protocol (SNMP) and the Syslog protocol...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
Linköpings universitet, Institutionen för datavetenskap
2020
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-166956 |
id |
ndltd-UPSALLA1-oai-DiVA.org-liu-166956 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-liu-1669562021-04-27T05:29:29ZMonitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional NetworkengÖvervakning av ett modellerat realtidssystem : Enkelriktat nätverk möjliggjort av dioderSterneling, HannaLinköpings universitet, Institutionen för datavetenskap2020Data diodelogging and managementmonitoringSMBSNMPSyslogEngineering and TechnologyTeknik och teknologierComputer and Information SciencesData- och informationsvetenskapMonitoring and logging is fundamental in systems. Today, these techniques are widely used to detect functionality issues as well as malicious event. This thesis compares and evaluates two techniques commonly used for this purpose: the Simple Network Management Protocol (SNMP) and the Syslog protocol. The protocols are evaluated with regard to their vulnerability to traffic pattern analysis, impact on network load and performance of the system, and the attack surface of the technique. Each protocol’s applicability is investigated on a modelled system, containing a data diode, using experiments and analysis of their individual features. We observe only small differences in traffic load and performance of the two techniques. The findings suggest that each of the two techniques can successfully be applied on the modelled system, and the decision on which technique should be used at each instance can therefore be left to the customer of each specific system implementation instance. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-166956application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Data diode logging and management monitoring SMB SNMP Syslog Engineering and Technology Teknik och teknologier Computer and Information Sciences Data- och informationsvetenskap |
spellingShingle |
Data diode logging and management monitoring SMB SNMP Syslog Engineering and Technology Teknik och teknologier Computer and Information Sciences Data- och informationsvetenskap Sterneling, Hanna Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network |
description |
Monitoring and logging is fundamental in systems. Today, these techniques are widely used to detect functionality issues as well as malicious event. This thesis compares and evaluates two techniques commonly used for this purpose: the Simple Network Management Protocol (SNMP) and the Syslog protocol. The protocols are evaluated with regard to their vulnerability to traffic pattern analysis, impact on network load and performance of the system, and the attack surface of the technique. Each protocol’s applicability is investigated on a modelled system, containing a data diode, using experiments and analysis of their individual features. We observe only small differences in traffic load and performance of the two techniques. The findings suggest that each of the two techniques can successfully be applied on the modelled system, and the decision on which technique should be used at each instance can therefore be left to the customer of each specific system implementation instance. |
author |
Sterneling, Hanna |
author_facet |
Sterneling, Hanna |
author_sort |
Sterneling, Hanna |
title |
Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network |
title_short |
Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network |
title_full |
Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network |
title_fullStr |
Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network |
title_full_unstemmed |
Monitoring of a Modelled Real-Time System : with Data Diode Enabled Unidirectional Network |
title_sort |
monitoring of a modelled real-time system : with data diode enabled unidirectional network |
publisher |
Linköpings universitet, Institutionen för datavetenskap |
publishDate |
2020 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-166956 |
work_keys_str_mv |
AT sternelinghanna monitoringofamodelledrealtimesystemwithdatadiodeenabledunidirectionalnetwork AT sternelinghanna overvakningavettmodelleratrealtidssystemenkelriktatnatverkmojliggjortavdioder |
_version_ |
1719399246387478528 |