New approaches to monitoring of cardiac function

Left ventricular pumping performance may be described by intraventricular pressure and volume variables, usually presented as a pressure-volume plot. However, on-line monitoring of left ventricular pressure and volume with high temporal resolution requires the use of an invasive catheter technique s...

Full description

Bibliographic Details
Main Author: Söderqvist, Emil
Format: Doctoral Thesis
Language:English
Published: KTH, Skolan för teknik och hälsa (STH) 2006
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-4211
http://nbn-resolving.de/urn:isbn:978-91-7178-507-7
Description
Summary:Left ventricular pumping performance may be described by intraventricular pressure and volume variables, usually presented as a pressure-volume plot. However, on-line monitoring of left ventricular pressure and volume with high temporal resolution requires the use of an invasive catheter technique such as, for example, the conductance catheter method. On the other hand, the very invasiveness and complexity of this approach makes it less suitable for clinical use. It is then not surprising that there has been long-felt need to make the conductance method less invasive and attempts have been made to adjust the method to clinical demands and routine in order to extract more information from pressure-volume interplay and possibly translate relevant data to their non-invasive estimates. In the present studies, a standard five segmental conductance catheter was used in animal (pig) experiments. Segmental conductances were compared to global conductance. Since the mid-ventricular segment was shown to reflect global volume, which was also shown on theoretical basis, it was concluded that a single segmental catheter most probably could be used to estimate global left ventricular volume. Subsequently, a thin and flexible single segmental conductance catheter was constructed and applied to an animal (pig) experimental model. Results were reproducible and very few arrythmias were detected. At the next stage, left ventricular isovolumic phases were investigated using the standard conductance catheter method, as well as echocardiographically derived tissue velocity doppler. Conductance was shown to decrease during isovolumic contraction, and an adjustment method was proposed in order to account for the subsequent decrease in pressure-volume loop area. In separate experiments, the left ventricular pressure wave form during left ventricular systole was examined, and an algorithm was proposed to discriminate between the changes in afterload, preload and contractility. Results showed clearly discernible patterns of the respective load and contractility alternation. Finally, the left ventricular continuous area was monitored continuously during the entire cardiac cycle as a measure of left ventricular volume dynamics in normal subjects and three patients with left ventricular abnormalities using echocardiographic automatic boundary detection. The left ventricular area thus obtained was plotted against its first derivative, to form a flow-volume estimates loop, in accordance with the flow-volume examinations used in respiratory physiology. Data obtained from the abnormal ventricles were presented as flow-volume estimates loops, exemplifying the possible use of the method. === QC 20100922