Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development

Doppler echocardiography is the conventional method for measurement of myocardial motion. However, the same clinical parameters can be measured with phase contrast magnetic resonance imaging (MRI). Suppression of the blood signal with black-blood methods can reduce flow-related artifacts that may af...

Full description

Bibliographic Details
Main Author: Borromeo, Reenalyn
Format: Others
Language:English
Published: KTH, Skolan för kemi, bioteknologi och hälsa (CBH) 2020
Subjects:
MRI
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-286773
id ndltd-UPSALLA1-oai-DiVA.org-kth-286773
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-kth-2867732020-12-10T05:29:52ZBlack-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence DevelopmentengUtsläckning av blodsignal genom applicering av stimulerade ekon vid faskontrastavbildning med magnetisk resonanstomografi : PulssekvensutvecklingBorromeo, ReenalynKTH, Skolan för kemi, bioteknologi och hälsa (CBH)2020MRIphase contrastblack bloodSTEAMmyocardial motionMRImagnetisk resonanstomografifaskontrastblodutsläckningSTEAMmyokardiell rörelseMedical EngineeringMedicinteknikDoppler echocardiography is the conventional method for measurement of myocardial motion. However, the same clinical parameters can be measured with phase contrast magnetic resonance imaging (MRI). Suppression of the blood signal with black-blood methods can reduce flow-related artifacts that may affect quantitative measurements with phase contrast MRI. Conventional blood suppression techniques are not time efficient and a potential approach to achieve the black-blood effect in phase contrast imaging is through application of stimulated echo acquisition mode (STEAM). This thesis describes the development of a pulse sequence where a STEAM-based preparation was combined with conventional phase contrast imaging to achieve a black-blood effect in the produced images.The results of the performed imaging experiments showed that black-blood contrast was achieved with the proposed pulse sequence, and the blood suppression was also maintained during the cardiac cycle. Myocardial tissue velocity measurement with the suggested approach showed good agreement with conventional phase contrast imaging. It was concluded that black-blood phase contrast imaging can be achieved through the application of a STEAM-based preparation. Dopplerekokardiografi är den konventionella metoden för mätning av myokardiell rörelse. Liknande mätningar kan dock utföras genom faskontrastavbildning som är en metod inom magnetisk resonanstomografi. Signal från blod kan orsaka flödesrelaterade bildartefakter vid faskontrastavbildning som kan påverka hastighetsmätningar i myokardiet. Utsläckning av blodsignalen kan mitigera artefakternas påverkan på kvantitativa mätningar som utförs med faskontrast. Konventionella metoder för utsläckning av blodsignalen är inte tidseffektiva och en potentiell metod för att åstadkomma blodutsläckning vid faskontrastavbildning är applicering av en preparation baserad på stimulated echo acquisition mode (STEAM). I detta arbete utvecklades en pulssekvens där en STEAM-baserad preparation kombinerades med en traditionell faskontrastsekvens. De resulterande bilderna visade att blodutsläckning hade åstadkommits och att denna effekt kunde bibehållas under hjärtcykelns gång. Hastighetsmätningar utfördes även i myokardiet och var jämförbara med traditionell faskontrast. Slutsatsen var att utsläckning av blodsignalen vid faskontrastavbildning är möjligt genom applicering av en STEAM-baserad preparation. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-286773TRITA-CBH-GRU ; 2020:279application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
topic MRI
phase contrast
black blood
STEAM
myocardial motion
MRI
magnetisk resonanstomografi
faskontrast
blodutsläckning
STEAM
myokardiell rörelse
Medical Engineering
Medicinteknik
spellingShingle MRI
phase contrast
black blood
STEAM
myocardial motion
MRI
magnetisk resonanstomografi
faskontrast
blodutsläckning
STEAM
myokardiell rörelse
Medical Engineering
Medicinteknik
Borromeo, Reenalyn
Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
description Doppler echocardiography is the conventional method for measurement of myocardial motion. However, the same clinical parameters can be measured with phase contrast magnetic resonance imaging (MRI). Suppression of the blood signal with black-blood methods can reduce flow-related artifacts that may affect quantitative measurements with phase contrast MRI. Conventional blood suppression techniques are not time efficient and a potential approach to achieve the black-blood effect in phase contrast imaging is through application of stimulated echo acquisition mode (STEAM). This thesis describes the development of a pulse sequence where a STEAM-based preparation was combined with conventional phase contrast imaging to achieve a black-blood effect in the produced images.The results of the performed imaging experiments showed that black-blood contrast was achieved with the proposed pulse sequence, and the blood suppression was also maintained during the cardiac cycle. Myocardial tissue velocity measurement with the suggested approach showed good agreement with conventional phase contrast imaging. It was concluded that black-blood phase contrast imaging can be achieved through the application of a STEAM-based preparation. === Dopplerekokardiografi är den konventionella metoden för mätning av myokardiell rörelse. Liknande mätningar kan dock utföras genom faskontrastavbildning som är en metod inom magnetisk resonanstomografi. Signal från blod kan orsaka flödesrelaterade bildartefakter vid faskontrastavbildning som kan påverka hastighetsmätningar i myokardiet. Utsläckning av blodsignalen kan mitigera artefakternas påverkan på kvantitativa mätningar som utförs med faskontrast. Konventionella metoder för utsläckning av blodsignalen är inte tidseffektiva och en potentiell metod för att åstadkomma blodutsläckning vid faskontrastavbildning är applicering av en preparation baserad på stimulated echo acquisition mode (STEAM). I detta arbete utvecklades en pulssekvens där en STEAM-baserad preparation kombinerades med en traditionell faskontrastsekvens. De resulterande bilderna visade att blodutsläckning hade åstadkommits och att denna effekt kunde bibehållas under hjärtcykelns gång. Hastighetsmätningar utfördes även i myokardiet och var jämförbara med traditionell faskontrast. Slutsatsen var att utsläckning av blodsignalen vid faskontrastavbildning är möjligt genom applicering av en STEAM-baserad preparation.
author Borromeo, Reenalyn
author_facet Borromeo, Reenalyn
author_sort Borromeo, Reenalyn
title Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
title_short Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
title_full Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
title_fullStr Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
title_full_unstemmed Black-Blood Phase Contrast Magnetic Resonance Imaging using Stimulated Echo Acquisition Mode : Pulse Sequence Development
title_sort black-blood phase contrast magnetic resonance imaging using stimulated echo acquisition mode : pulse sequence development
publisher KTH, Skolan för kemi, bioteknologi och hälsa (CBH)
publishDate 2020
url http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-286773
work_keys_str_mv AT borromeoreenalyn blackbloodphasecontrastmagneticresonanceimagingusingstimulatedechoacquisitionmodepulsesequencedevelopment
AT borromeoreenalyn utslackningavblodsignalgenomappliceringavstimuleradeekonvidfaskontrastavbildningmedmagnetiskresonanstomografipulssekvensutveckling
_version_ 1719370050481160192