Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket
Goals: Increase the efficiency in the operation of the auxiliary boilers, and the utilization of the rock-cavern storage under a tecno- economic lens. Including in the work is modification and improvement of the plants documents regarding the planning of consumers in the auxiliary steam system. More...
Main Authors: | , |
---|---|
Format: | Others |
Language: | English |
Published: |
KTH, Energiteknik
2020
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-283561 |
id |
ndltd-UPSALLA1-oai-DiVA.org-kth-283561 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-kth-2835612020-10-08T05:27:18ZImprovement of energy efficiency of the auxiliary steam system and rock-cavern storage at KarlshamnverketengEnergieffektivisering av hjälpångsystem och bergrumslager vid KarlshamnsverketHammarling, MagnusJohansson, HugoKTH, EnergiteknikKTH, Energiteknik2020Engineering and TechnologyTeknik och teknologierGoals: Increase the efficiency in the operation of the auxiliary boilers, and the utilization of the rock-cavern storage under a tecno- economic lens. Including in the work is modification and improvement of the plants documents regarding the planning of consumers in the auxiliary steam system. Moreover, is energy saving measures examined in the rock-cavern storage, based on own developed model of its energy losses. Method: A model was developed of the rock-cavern storage, including the piping system down to the storage. Estimations of the energy heat loss, and heating of waterbed was achieved, and based on these estimations where energy saving implementations examined based on the payback method. Conclusions: The energy losses in the rock storage caverns are expected to be somewhere between 07 and 1,1MW depending on the water beds temperature, the water leaking in and the oil level in the caverns. The smallest size of local heating device to accommodate the needs of the plants personnel is expected to be 2MW. The switch to a locally installed electric hot water boiler is expected to save electricity equivalent to about 440 000 to 100 000 SEK per year which equals to an average payback time of around 6,7 years. The modelled pipes that today lead the steam to the storages were calculated to account for about 4% of the total static losses from the steam system. Mål: Effektivisera driften av hjälpångpannorna samt utnyttjandet av bergrumslagret under ett tekno ekonomiskt perspektiv. I detta ingår det att modifiera existerande planeringsdokument för att kunna ekonomiskt planera driften av konsumenter för elångpanna, samt undersöka energibesparande åtgärder i bergrummen baserad på egen framtagen modellering av bergrummet. Metod: Analys av bergrummen och inkluderat rörsystem utifrån modell byggd på insamlad data från anläggningen och göra uppskattningar av energiförbrukning vid uppvärmning av bäddvatten samt lagring av bergrum. Därifrån ges förslag på åtgärder med ekonomiska beräkningar som ska reducera energiförbrukning på anläggningen. Slutsatser: Energiförlusterna i bergrum uppgår till mellan 0,7 och 1,1MW kontinuerligt beroende på vattenbäddstemperatur, inläckande vatten och oljenivå. Minsta storlek på lokal värmekälla uppskattas vara ca 2MW. Ett byte till uppvärmning av hetvatten med direktverkande el skulle kunna medföra ekonomiska besparingar mellan 440 000 och 100 000 kr per år. Detta leder till en genomsnittlig återbetalningstid på ca 6,7 år. De modellerade rören vilka i dag leder ånga till bergrummen visade sig står för ca 4% av de totala statiska förlusterna av hjälpångsystemet. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-283561TRITA-ITM-EX ; 2020:479application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Engineering and Technology Teknik och teknologier |
spellingShingle |
Engineering and Technology Teknik och teknologier Hammarling, Magnus Johansson, Hugo Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket |
description |
Goals: Increase the efficiency in the operation of the auxiliary boilers, and the utilization of the rock-cavern storage under a tecno- economic lens. Including in the work is modification and improvement of the plants documents regarding the planning of consumers in the auxiliary steam system. Moreover, is energy saving measures examined in the rock-cavern storage, based on own developed model of its energy losses. Method: A model was developed of the rock-cavern storage, including the piping system down to the storage. Estimations of the energy heat loss, and heating of waterbed was achieved, and based on these estimations where energy saving implementations examined based on the payback method. Conclusions: The energy losses in the rock storage caverns are expected to be somewhere between 07 and 1,1MW depending on the water beds temperature, the water leaking in and the oil level in the caverns. The smallest size of local heating device to accommodate the needs of the plants personnel is expected to be 2MW. The switch to a locally installed electric hot water boiler is expected to save electricity equivalent to about 440 000 to 100 000 SEK per year which equals to an average payback time of around 6,7 years. The modelled pipes that today lead the steam to the storages were calculated to account for about 4% of the total static losses from the steam system. === Mål: Effektivisera driften av hjälpångpannorna samt utnyttjandet av bergrumslagret under ett tekno ekonomiskt perspektiv. I detta ingår det att modifiera existerande planeringsdokument för att kunna ekonomiskt planera driften av konsumenter för elångpanna, samt undersöka energibesparande åtgärder i bergrummen baserad på egen framtagen modellering av bergrummet. Metod: Analys av bergrummen och inkluderat rörsystem utifrån modell byggd på insamlad data från anläggningen och göra uppskattningar av energiförbrukning vid uppvärmning av bäddvatten samt lagring av bergrum. Därifrån ges förslag på åtgärder med ekonomiska beräkningar som ska reducera energiförbrukning på anläggningen. Slutsatser: Energiförlusterna i bergrum uppgår till mellan 0,7 och 1,1MW kontinuerligt beroende på vattenbäddstemperatur, inläckande vatten och oljenivå. Minsta storlek på lokal värmekälla uppskattas vara ca 2MW. Ett byte till uppvärmning av hetvatten med direktverkande el skulle kunna medföra ekonomiska besparingar mellan 440 000 och 100 000 kr per år. Detta leder till en genomsnittlig återbetalningstid på ca 6,7 år. De modellerade rören vilka i dag leder ånga till bergrummen visade sig står för ca 4% av de totala statiska förlusterna av hjälpångsystemet. |
author |
Hammarling, Magnus Johansson, Hugo |
author_facet |
Hammarling, Magnus Johansson, Hugo |
author_sort |
Hammarling, Magnus |
title |
Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket |
title_short |
Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket |
title_full |
Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket |
title_fullStr |
Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket |
title_full_unstemmed |
Improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at Karlshamnverket |
title_sort |
improvement of energy efficiency of the auxiliary steam system and rock-cavern storage at karlshamnverket |
publisher |
KTH, Energiteknik |
publishDate |
2020 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-283561 |
work_keys_str_mv |
AT hammarlingmagnus improvementofenergyefficiencyoftheauxiliarysteamsystemandrockcavernstorageatkarlshamnverket AT johanssonhugo improvementofenergyefficiencyoftheauxiliarysteamsystemandrockcavernstorageatkarlshamnverket AT hammarlingmagnus energieffektiviseringavhjalpangsystemochbergrumslagervidkarlshamnsverket AT johanssonhugo energieffektiviseringavhjalpangsystemochbergrumslagervidkarlshamnsverket |
_version_ |
1719351290773897216 |