Dynamic soil-structure interaction of simply supported high-speed railway bridges

Research performed on the subject of dynamic soil-structure interaction (SS) concerning railway bridges is presented in this thesis with the focus on simply supported railway bridges supported by shallow foundations in soil strata on bedrock. The research aims to obtain insight into the SSI of high-...

Full description

Bibliographic Details
Main Author: Lind Östlund, Johan
Format: Others
Language:English
Published: KTH, Bro- och stålbyggnad 2020
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-279651
http://nbn-resolving.de/urn:isbn:978-91-7873-616-4
Description
Summary:Research performed on the subject of dynamic soil-structure interaction (SS) concerning railway bridges is presented in this thesis with the focus on simply supported railway bridges supported by shallow foundations in soil strata on bedrock. The research aims to obtain insight into the SSI of high-speed railway bridges and to provide recommendations on how to model the soil-bridge system from a design perspective. A three-dimensional (3D) simply supported soil-bridge model was first developed and the effects from model assumptions made on the soil-foundation system was evaluated in a 3D setting (paper I). The soil-foundation system was then refined and a model assumptions study was performed in order to evaluate the effects of model assumptions on impedance functions, including the influence of the permanent load acting on the soil-foundation system (paper II). Finally, a study of the assembled soil-bridge system was performed in an extensive parametric study including a set of 2D bridge models in combination with a set of shallow foundations in soil strata on bedrock (paper III). A supplementary section related to paper III was also added in this thesis, showing the effects of the substructure mass. The model assumptions made when creating the soil-foundation model and the soil-bridge model can be very important and must be made with care. The permanent load acting on the soil-foundation systems of shallow foundations may alter the impedance functions significantly. The substructure mass may alter the behavior of the soil-bridge system depending on its magnitude, and neglecting it gives inaccurate results. The 3D effects of SSI do not cause high vibrations due to modes other than the first bending mode, and assuming a 2D bridge model is generally acceptable. The effects of SSI on the soil-bridge systems with shallow soil strata are largely dependent on the ratio between the natural frequency of the bridge and the fundamental frequency of the soil. Depending on the value of this ratio, the effect of including SSI in bridge models may contribute to the bridge obtaining a negligible, conservative, or non-conservative response, as compared to the bridge with the assumption of non-flexible supports. === Forskning i syfte att utröna effekten av dynamisk jord–struktur-interaktion (SSI)på järnvägsbroar presenteras i denna avhandling med huvudfokus på fritt upplagdabroar med stöd av plattgrundlagda fundament i jordar på fast berggrund. Forsknin-gen syftar till att ge förståelse för interaktionen mellan jord och järnvägsbroar samtatt ge rekommendationer på hur systemet kan modelleras ur ett designperspektiv.En tredimensionell (3D) fritt upplagd jord–bromodell utvecklades först och effek-terna av modellantaganden gjorda på jord–grundläggningssystemet utvärderadesi en 3D miljö (artikel I). Jord–grundläggningssystemet förfinades och en studiegenomfördes för att utvärdera effekterna av modellantaganden på impedansfunk-tioner, inklusive påverkan av den permanenta belastningen som verkar på jord–grundläggningssystemet (artikel II). Slutligen utfördes en omfattande parametriskstudie av det sammansatta jord–brosystemet där en uppsättning tvådimensionella(2D) bromodeller kombinerades med en uppsättning jordar (artikel III). Ett kom-pletterande avsnitt relaterat till artikel III lades till i denna avhandling som visareffekterna av massan av underbyggnaden på jord–brosystemet.De modellantaganden som görs vid skapandet av jord–grundläggningsmodeller ochjord–bromodeller kan vara mycket viktiga och bör utföras med varsamhet. Den per-manenta belastningen som verkar på jord–grundläggningssystemet kan väsentligtförändra impedansfunktionerna. Massan av underbyggnaden kan vidare ändra re-sponsen i jord–brosystemet, beroende på dess storlek, och att försumma den kan gefelaktiga resultat. De 3D effekterna av SSI orsakar inte höga vibrationer på grundav andra moder än den första böjmoden, och att anta en 2D bromodell är såledesgenerellt sett motiverat.Effekterna av SSI på jord–brosystemet i grunda jordar beror till stor del av kvotenmellan brons naturliga frekvens och jordens fundamentala frekvens. Beroende påvärdet på denna kvot kan effekten av att inkludera SSI i bromodeller bidra till attbron får en försumbar, konservativ, eller icke-konservativ respons, i jämförelse medbron med antagandet om fasta upplag. === <p>QC 20200903</p>