Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits
Cepheid provides instruments and tests for molecular diagnostic testing of bacterial and viral diseases. Their goal is to deliver a better way to improve patient outcomes by enabling access to molecular diagnostic testing everywhere. These test kits are used in warm and humid countries which may cha...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
KTH, Kemiteknik
2019
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-266375 |
id |
ndltd-UPSALLA1-oai-DiVA.org-kth-266375 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-kth-2663752020-01-10T15:44:30ZOptimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kitsengOptimering av modifierad fuktmätningsmetod med Karl Fischer för att mäta fuktinnehållet i frystorkade enzymkulor för förbättring av diagnostiska kiJakobsson, CatharinaKTH, Kemiteknik2019Mettler Toledo C30S Compact Karl Fischer-coulometerChemical EngineeringKemiteknikCepheid provides instruments and tests for molecular diagnostic testing of bacterial and viral diseases. Their goal is to deliver a better way to improve patient outcomes by enabling access to molecular diagnostic testing everywhere. These test kits are used in warm and humid countries which may challenge the stability of the kits. The test kits containly ophilized beads, which contain enzymes for the polymerase chain reaction, which usually ages first. The ageing of the beads is effected by the initial water content in them since it defines the quality. Therefore, it is of great importance to have a very precise and exact water measurement method. The degree project covers the optimization of the Standard Operating Procedure used today at Cepheid with the research question: Can optimization of the Karl Fischer method improve the precision when measuring the initial moisture content of freeze-dried enzyme beads? The method for measuring the water content was the Karl Fischer titration method and the instrument used was the Mettler Toledo C30S Compact Karl Fischer-coulometer. The different optimized parameters were the sample preparation, extraction process and how the measurement was proceeded. It can be concluded that optimized method provides significantly different results compared with the old method and therefore the new method is better. Cepheid tillverkar instrument och test för molekylär diagnostisk testning av bakteriella och virala sjukdomar. Målet är att leverera en lösning som leder till en förbättring för patienterna genom att möjliggöra tillgång till molekylär diagnostisk var än den behöver utföras i världen, under stora variationer i mätmiljön. Dessa testkit används i varma och fuktigalä nder vilket kan utmana stabiliteten hos produkten. Testen innehåller lyofiliserade kulor och det är dessa som vanligtvis åldras först. Kulornas hållbarhet påverkas av den ursprungliga vattenhalten, vilket definierar kvalit´en. Därför är det mycket viktigt att ha en mycket exakt metod att mäta fuktinnehållet i kulorna. Examensarbetet omfattar optimering av den standardoperativa proceduren som används idag på Cepheid och fr°ageställningen är: Kan optimering av Karl Fischer-metoden förbättra precisionen vid mätning av det ursprungliga fuktinnehållet i frystorkade enzymkulor?Den metod som används vid mätningen av vattenhalten är Karl Fischer-titreringsmetoden och instrumentet som användes var Mettler Toledo C30S Compact Karl Fischer-coulometer. De olika optimerade parametrarna var: förberedelsen av proven, extraktionsprocessen och själva utförandet av mätningen.Den slutsats som kan dras efter optimeringen är att den nya metoden ger ett mer exakt och bättre resultat än den gamla. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-266375application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Mettler Toledo C30S Compact Karl Fischer-coulometer Chemical Engineering Kemiteknik |
spellingShingle |
Mettler Toledo C30S Compact Karl Fischer-coulometer Chemical Engineering Kemiteknik Jakobsson, Catharina Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
description |
Cepheid provides instruments and tests for molecular diagnostic testing of bacterial and viral diseases. Their goal is to deliver a better way to improve patient outcomes by enabling access to molecular diagnostic testing everywhere. These test kits are used in warm and humid countries which may challenge the stability of the kits. The test kits containly ophilized beads, which contain enzymes for the polymerase chain reaction, which usually ages first. The ageing of the beads is effected by the initial water content in them since it defines the quality. Therefore, it is of great importance to have a very precise and exact water measurement method. The degree project covers the optimization of the Standard Operating Procedure used today at Cepheid with the research question: Can optimization of the Karl Fischer method improve the precision when measuring the initial moisture content of freeze-dried enzyme beads? The method for measuring the water content was the Karl Fischer titration method and the instrument used was the Mettler Toledo C30S Compact Karl Fischer-coulometer. The different optimized parameters were the sample preparation, extraction process and how the measurement was proceeded. It can be concluded that optimized method provides significantly different results compared with the old method and therefore the new method is better. === Cepheid tillverkar instrument och test för molekylär diagnostisk testning av bakteriella och virala sjukdomar. Målet är att leverera en lösning som leder till en förbättring för patienterna genom att möjliggöra tillgång till molekylär diagnostisk var än den behöver utföras i världen, under stora variationer i mätmiljön. Dessa testkit används i varma och fuktigalä nder vilket kan utmana stabiliteten hos produkten. Testen innehåller lyofiliserade kulor och det är dessa som vanligtvis åldras först. Kulornas hållbarhet påverkas av den ursprungliga vattenhalten, vilket definierar kvalit´en. Därför är det mycket viktigt att ha en mycket exakt metod att mäta fuktinnehållet i kulorna. Examensarbetet omfattar optimering av den standardoperativa proceduren som används idag på Cepheid och fr°ageställningen är: Kan optimering av Karl Fischer-metoden förbättra precisionen vid mätning av det ursprungliga fuktinnehållet i frystorkade enzymkulor?Den metod som används vid mätningen av vattenhalten är Karl Fischer-titreringsmetoden och instrumentet som användes var Mettler Toledo C30S Compact Karl Fischer-coulometer. De olika optimerade parametrarna var: förberedelsen av proven, extraktionsprocessen och själva utförandet av mätningen.Den slutsats som kan dras efter optimeringen är att den nya metoden ger ett mer exakt och bättre resultat än den gamla. |
author |
Jakobsson, Catharina |
author_facet |
Jakobsson, Catharina |
author_sort |
Jakobsson, Catharina |
title |
Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
title_short |
Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
title_full |
Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
title_fullStr |
Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
title_full_unstemmed |
Optimization of modified moisture measurement with Karl Fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
title_sort |
optimization of modified moisture measurement with karl fischer to measure moisture content in freeze-dried enzyme beads for improvement of diagnostic kits |
publisher |
KTH, Kemiteknik |
publishDate |
2019 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-266375 |
work_keys_str_mv |
AT jakobssoncatharina optimizationofmodifiedmoisturemeasurementwithkarlfischertomeasuremoisturecontentinfreezedriedenzymebeadsforimprovementofdiagnostickits AT jakobssoncatharina optimeringavmodifieradfuktmatningsmetodmedkarlfischerforattmatafuktinnehalletifrystorkadeenzymkulorforforbattringavdiagnostiskaki |
_version_ |
1719307933496377344 |