Influence on tip leakage flow in a compressor cascade with plasma actuation

As one of the key components of aero engines, compressor is required to endure higher pressure,  possess  higher  efficiency  and  wider  operating  range. Intensive studies have been made on tip leakage flow and researchers find that by reasonably organizing tip leakage flow, aero engines are  more...

Full description

Bibliographic Details
Main Author: Wang, Haotian
Format: Others
Language:English
Published: KTH, Skolan för industriell teknik och management (ITM) 2019
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-264269
id ndltd-UPSALLA1-oai-DiVA.org-kth-264269
record_format oai_dc
collection NDLTD
language English
format Others
sources NDLTD
topic Flow control
DBD Plasma actuation
phenomenological model
numerical simulation
tip leakage flow
compressor cascade.
Flödesreglering
DBD Plasma‐aktuator
numerisk simulering
toppspelsflöde
kompressor kaskad.
Engineering and Technology
Teknik och teknologier
spellingShingle Flow control
DBD Plasma actuation
phenomenological model
numerical simulation
tip leakage flow
compressor cascade.
Flödesreglering
DBD Plasma‐aktuator
numerisk simulering
toppspelsflöde
kompressor kaskad.
Engineering and Technology
Teknik och teknologier
Wang, Haotian
Influence on tip leakage flow in a compressor cascade with plasma actuation
description As one of the key components of aero engines, compressor is required to endure higher pressure,  possess  higher  efficiency  and  wider  operating  range. Intensive studies have been made on tip leakage flow and researchers find that by reasonably organizing tip leakage flow, aero engines are  more likely to achieve better performance and reliability. Conventional flow controlling methods  like casing treatment and micro jet could substantially modify tip leakage flow, unfortunately with  a price of additional loss, not to mention the difficulty in manufacturing such structure. Whereas  plasma actuation  flow control method  uses  plasma actuators,  such equipment is easy  to  build,  responses  fast  and  has  a  wide  excitation  bandwidth.  This  method  has  become  a  new  trend  in  internal flow active control field.  In this research, a phenomenological model is adopted to simulate DBD plasma actuation in the  flow field inside a compressor cascade. The aim is to find out how plasma actuation will influence  tip  leakage  flow.  Meanwhile  possible  means  to  improve  plasma  actuation  performance  are  discussed.  First of all, numerical simulation of flow inside a compressor cascade without plasma actuation is  conducted to validate accuracy of the numerical methodology adopted and then determine one  numerical  approach  that  satisfies  specific  needs  sufficiently.  Meanwhile,  influence  of  casing  movement on tip leakage flow as well as possible mechanism of tip leakage vortex core generation  is investigated in detail. The results indicate:    1. Generating position of tip leakage vortex moves towards leading edge with increasing moving  speed of shroud.  2. As shroud moving speed increases, trajectory of tip leakage vortex moves away from suction  side of blade and closely towards shroud.  3. Casing movement  tends  to  transform  tip leakage vortex  from  circular  to  oval  shape  due  to  circumferential shearing.  4. Casing  movement  has  little  influence  on  total  pressure  field  concerning  absolute  pressure  value. While total pressure loss does reduce slightly with increasing moving speed of shroud.  5.Vorticity  transport  from  tip  clearance  into  passage  may  be  contributing  significantly  to  generation of tip leakage vortex inner core.  Secondly, a simplified model of DBD plasma actuation based on literature [1] is derived and applied  through  UDF  function  of  commercial  software  Fluent  into  the  flow  field.  Different  actuation  positions,  voltages  and  frequencies  are  applied  in  simulation  and  compared.  After  that  casing  movement is included. Main conclusions are as follow:    6. Plasma  actuation  shows  significant  suppressing  effect  on  tip  leakage  vortex  on  both  size,  trajectory and strength.  7. The suppressing effect on tip leakage vortex grows stronger as actuator moves towards leading  edge.  8. Increasing actuation voltage results in stronger suppressing effect on tip leakage vortex.  9. Plasma actuation can effectively improve total pressure loss situation near shroud region with  increasing actuation power.  10. Increasing actuation frequency results in stronger suppressing effect on tip leakage vortex as  well. Additionally, frequency performs slightly better than voltage. 11. Casing  movement  tends  to  weaken  suppressing  effect  of  tip  leakage  vortex  by  plasma  actuation. More  actuation  power  is  needed  to  achieve  sufficient  suppressing  effect  in  real  compressors.  === Som en av de viktigaste komponenterna i flygmotorer krävs det att kompressorn utsätts för högre  tryck, har högre effektivitet och  större driftsintervall. Intensiva  studier har gjorts om  skovlarnas  toppspel  läckageflöde  och  man  anser  att  det  är  mer  sannolikt  att  flygmotorer  uppnår  bättre  prestanda  och  tillförlitlighet  genom  att  på  ett  rimligt  sätt  reglera  läckageflödet  i  toppspelet.  Konventionella metoder  för reglering av flödet, som behandling av “casing” och mikrojet, skulle  kunna  ändra  läckageflödet  avsevärt,  men  medför  tyvärr  ytterligare  förlust,  för  att  inte  tala  om  svårigheten att tillverka en sådan struktur. Samtidig flödeskontroll med hjälp av plasma aktuatorer  som är relativt lätta att bygga, reagerar snabbt och har en bred excitationsbandvid. Denna metod  har blivit en ny trend inom det interna flödesaktiva kontrollområdet.  I  denna  forskning  antas  en  modell  för  att  simulera  plasmaaktivering  av  DBD  i  flödesfältet  i  en  kompressorskaskad. Man försöker ta reda på hur plasmaaktivering påverkar läckageflödet. Möjliga  sätt att förbättra effekten av plasmaaktivering diskuteras.  För  det  första  genomförs  numerisk  simulering  av  flödet  i  en  kompressorskaskad  utan  plasmaaktivering för att validera noggrannheten i den numeriska metoden. Därefter undersöks i  detalj vilken inverkan den relativa rörelsen av ”casing” har på läckageflödet genom toppspelet och  mekanismen för toppspelsvirvel analyseras. Resultaten visar:    1. Startposition för läckagevirveln rör sig mot skovelns framkant när man introducerar och ökar  den relativa hastigheten för ”casing”.    2. I takt med att den relativa hastigheten ökar, kretsbanan för    läckage virveln rör sig bort från  skovelns sugsida och närmare mot ”casing”.  3. Den  relativa  rörelsen  tenderar  att  omvandla  virveln  från  cirkulär  till  oval  form  på  grund  av  skjuvkrafter.  4. Den relativa rörelsen av ”casing” påverkar inte det totala tryckfältet när det gäller det absoluta  tryckvärdet. Samtidigt som den totala tryckförlusten minskar något med ökad hastighet.  5. Virveltransport från toppspelet till huvudkanalen kan på ett betydande sätt bidra till att skapa  virvelns inre kärna.  I senare delen av arbetet utvecklas och tillämpas en förenklad modell för plasmaaktivering av DBD  baserad  på  litteratur  [1],  genom  att  använda  UDF‐funktionen  i  kommersiell  CFD  programvara  Fluent.  Olika  aktuatorläge,  spänningar  och  frekvenser  prövas  i  simuleringen  och  jämförs.  De  viktigaste slutsatserna är följande:    6. Aktuering av plasma visar en betydande dämpningseffekt på läckagevirveln i toppspelet både  va det gäller dess storlek, bana och styrka.  7. Den  dämpande  effekten  på  läckagevirveln  blir  starkare  när  aktuator  monteras  närmare  skovelns framkant.  8. Ökad aktuatorspänning leder till en starkare dämpande effekt på läckagevirveln.  9. Ökad aktuatorfrekvens leder till starkare dämpningseffekt på läckagevortex också.mDessutom  fungerar frekvensen något bättre än spänningen.  10. Den  relativa  rörelsen  av  ”casing”  försvagar  effekten  av  plasmaaktuering.  För  att  uppnå  tillräcklig dämpningseffekt i riktiga kompressorer krävs mer effekt till aktuatorn.
author Wang, Haotian
author_facet Wang, Haotian
author_sort Wang, Haotian
title Influence on tip leakage flow in a compressor cascade with plasma actuation
title_short Influence on tip leakage flow in a compressor cascade with plasma actuation
title_full Influence on tip leakage flow in a compressor cascade with plasma actuation
title_fullStr Influence on tip leakage flow in a compressor cascade with plasma actuation
title_full_unstemmed Influence on tip leakage flow in a compressor cascade with plasma actuation
title_sort influence on tip leakage flow in a compressor cascade with plasma actuation
publisher KTH, Skolan för industriell teknik och management (ITM)
publishDate 2019
url http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-264269
work_keys_str_mv AT wanghaotian influenceontipleakageflowinacompressorcascadewithplasmaactuation
_version_ 1719296228615782400
spelling ndltd-UPSALLA1-oai-DiVA.org-kth-2642692019-11-25T22:07:13ZInfluence on tip leakage flow in a compressor cascade with plasma actuationengWang, HaotianKTH, Skolan för industriell teknik och management (ITM)2019Flow controlDBD Plasma actuationphenomenological modelnumerical simulationtip leakage flowcompressor cascade.FlödesregleringDBD Plasma‐aktuatornumerisk simuleringtoppspelsflödekompressor kaskad.Engineering and TechnologyTeknik och teknologierAs one of the key components of aero engines, compressor is required to endure higher pressure,  possess  higher  efficiency  and  wider  operating  range. Intensive studies have been made on tip leakage flow and researchers find that by reasonably organizing tip leakage flow, aero engines are  more likely to achieve better performance and reliability. Conventional flow controlling methods  like casing treatment and micro jet could substantially modify tip leakage flow, unfortunately with  a price of additional loss, not to mention the difficulty in manufacturing such structure. Whereas  plasma actuation  flow control method  uses  plasma actuators,  such equipment is easy  to  build,  responses  fast  and  has  a  wide  excitation  bandwidth.  This  method  has  become  a  new  trend  in  internal flow active control field.  In this research, a phenomenological model is adopted to simulate DBD plasma actuation in the  flow field inside a compressor cascade. The aim is to find out how plasma actuation will influence  tip  leakage  flow.  Meanwhile  possible  means  to  improve  plasma  actuation  performance  are  discussed.  First of all, numerical simulation of flow inside a compressor cascade without plasma actuation is  conducted to validate accuracy of the numerical methodology adopted and then determine one  numerical  approach  that  satisfies  specific  needs  sufficiently.  Meanwhile,  influence  of  casing  movement on tip leakage flow as well as possible mechanism of tip leakage vortex core generation  is investigated in detail. The results indicate:    1. Generating position of tip leakage vortex moves towards leading edge with increasing moving  speed of shroud.  2. As shroud moving speed increases, trajectory of tip leakage vortex moves away from suction  side of blade and closely towards shroud.  3. Casing movement  tends  to  transform  tip leakage vortex  from  circular  to  oval  shape  due  to  circumferential shearing.  4. Casing  movement  has  little  influence  on  total  pressure  field  concerning  absolute  pressure  value. While total pressure loss does reduce slightly with increasing moving speed of shroud.  5.Vorticity  transport  from  tip  clearance  into  passage  may  be  contributing  significantly  to  generation of tip leakage vortex inner core.  Secondly, a simplified model of DBD plasma actuation based on literature [1] is derived and applied  through  UDF  function  of  commercial  software  Fluent  into  the  flow  field.  Different  actuation  positions,  voltages  and  frequencies  are  applied  in  simulation  and  compared.  After  that  casing  movement is included. Main conclusions are as follow:    6. Plasma  actuation  shows  significant  suppressing  effect  on  tip  leakage  vortex  on  both  size,  trajectory and strength.  7. The suppressing effect on tip leakage vortex grows stronger as actuator moves towards leading  edge.  8. Increasing actuation voltage results in stronger suppressing effect on tip leakage vortex.  9. Plasma actuation can effectively improve total pressure loss situation near shroud region with  increasing actuation power.  10. Increasing actuation frequency results in stronger suppressing effect on tip leakage vortex as  well. Additionally, frequency performs slightly better than voltage. 11. Casing  movement  tends  to  weaken  suppressing  effect  of  tip  leakage  vortex  by  plasma  actuation. More  actuation  power  is  needed  to  achieve  sufficient  suppressing  effect  in  real  compressors.  Som en av de viktigaste komponenterna i flygmotorer krävs det att kompressorn utsätts för högre  tryck, har högre effektivitet och  större driftsintervall. Intensiva  studier har gjorts om  skovlarnas  toppspel  läckageflöde  och  man  anser  att  det  är  mer  sannolikt  att  flygmotorer  uppnår  bättre  prestanda  och  tillförlitlighet  genom  att  på  ett  rimligt  sätt  reglera  läckageflödet  i  toppspelet.  Konventionella metoder  för reglering av flödet, som behandling av “casing” och mikrojet, skulle  kunna  ändra  läckageflödet  avsevärt,  men  medför  tyvärr  ytterligare  förlust,  för  att  inte  tala  om  svårigheten att tillverka en sådan struktur. Samtidig flödeskontroll med hjälp av plasma aktuatorer  som är relativt lätta att bygga, reagerar snabbt och har en bred excitationsbandvid. Denna metod  har blivit en ny trend inom det interna flödesaktiva kontrollområdet.  I  denna  forskning  antas  en  modell  för  att  simulera  plasmaaktivering  av  DBD  i  flödesfältet  i  en  kompressorskaskad. Man försöker ta reda på hur plasmaaktivering påverkar läckageflödet. Möjliga  sätt att förbättra effekten av plasmaaktivering diskuteras.  För  det  första  genomförs  numerisk  simulering  av  flödet  i  en  kompressorskaskad  utan  plasmaaktivering för att validera noggrannheten i den numeriska metoden. Därefter undersöks i  detalj vilken inverkan den relativa rörelsen av ”casing” har på läckageflödet genom toppspelet och  mekanismen för toppspelsvirvel analyseras. Resultaten visar:    1. Startposition för läckagevirveln rör sig mot skovelns framkant när man introducerar och ökar  den relativa hastigheten för ”casing”.    2. I takt med att den relativa hastigheten ökar, kretsbanan för    läckage virveln rör sig bort från  skovelns sugsida och närmare mot ”casing”.  3. Den  relativa  rörelsen  tenderar  att  omvandla  virveln  från  cirkulär  till  oval  form  på  grund  av  skjuvkrafter.  4. Den relativa rörelsen av ”casing” påverkar inte det totala tryckfältet när det gäller det absoluta  tryckvärdet. Samtidigt som den totala tryckförlusten minskar något med ökad hastighet.  5. Virveltransport från toppspelet till huvudkanalen kan på ett betydande sätt bidra till att skapa  virvelns inre kärna.  I senare delen av arbetet utvecklas och tillämpas en förenklad modell för plasmaaktivering av DBD  baserad  på  litteratur  [1],  genom  att  använda  UDF‐funktionen  i  kommersiell  CFD  programvara  Fluent.  Olika  aktuatorläge,  spänningar  och  frekvenser  prövas  i  simuleringen  och  jämförs.  De  viktigaste slutsatserna är följande:    6. Aktuering av plasma visar en betydande dämpningseffekt på läckagevirveln i toppspelet både  va det gäller dess storlek, bana och styrka.  7. Den  dämpande  effekten  på  läckagevirveln  blir  starkare  när  aktuator  monteras  närmare  skovelns framkant.  8. Ökad aktuatorspänning leder till en starkare dämpande effekt på läckagevirveln.  9. Ökad aktuatorfrekvens leder till starkare dämpningseffekt på läckagevortex också.mDessutom  fungerar frekvensen något bättre än spänningen.  10. Den  relativa  rörelsen  av  ”casing”  försvagar  effekten  av  plasmaaktuering.  För  att  uppnå  tillräcklig dämpningseffekt i riktiga kompressorer krävs mer effekt till aktuatorn. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-264269TRITA-ITM-EX ; 2019:688application/pdfinfo:eu-repo/semantics/openAccess