Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study
The ability to maintain an independent living at higher age is closely linked to the physical function of an individual. The evaluation of the upper limbs, including the muscular strength of the shoulder, elbow or wrist has received little attention, yet arms are used in most daily tasks. The upper...
Main Author: | |
---|---|
Format: | Others |
Language: | English |
Published: |
KTH, Medicinteknik och hälsosystem
2019
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-255658 |
id |
ndltd-UPSALLA1-oai-DiVA.org-kth-255658 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-kth-2556582019-08-08T04:36:28ZMeasuring Shoulder Abduction in a Healthy and Young Population: A Feasibility StudyengMätning av axelabduktion i en frisk och ung befolkning: En genomförbarhetsstudieRodríguez, CristinaKTH, Medicinteknik och hälsosystem2019ShoulderAbductionMomentDynamic measurementsHealthy PatientsAxelAbduktionMomentDynamiska mätningarFriska patienterMedical Laboratory and Measurements TechnologiesMedicinsk laboratorie- och mätteknikThe ability to maintain an independent living at higher age is closely linked to the physical function of an individual. The evaluation of the upper limbs, including the muscular strength of the shoulder, elbow or wrist has received little attention, yet arms are used in most daily tasks. The upper extremity physical performancecan be measured in several ways but none of them has the recognition to be theprimary method. The aim of this experimental study is to test the new devicedeveloped by Erik Almgren and assess whether this can be a valid tool to reliablyassess abduction shoulder strength. Fourteen healthy young subjects participated in this study. After placing in the left wrist the new device, they performed three types of tests: Full Range of Motion, Static measurements and Dynamic measurements. Three trials were done in each test with a recovery of 30 seconds. The results of the study showed that the Static measurements were similar to the ones obtained in previous studies in the past for both angles and force. For the first time, the study includes dynamic measurements of the moment of the shoulderjoint. Peak dynamic moments were found to be on average 6.43 N·m ± 1.00 N·mfor the females and 7.90 N·m ±2.33 N·m. This value is 6% lower than the test population’s average maximum static moments- result which in accordance withthe inverse relationship between force and velocity. The feasibility of this new device to be used outside a biomechanics lab has been proved, however, further research needs to be done in order to validate angles and measurements of the subjects. Förmågan att uppehålla ett självständigt levnadssätt vid en högre ålder är näralänkat till den fysiska funktionen hos en individ. Utvärderingen av de övre armarna, däribland muskelstyrkan hos axlarna, armbågarna eller handlederna,har fått lite uppmärksamhet, trots att armarna används i många dagliga aktiviteter. Den övre extremitetens fysiska prestanda kan mätas på flera sätt men inget av dem har erkänts som det primära verktyget för underlag att kunna återvända till normal fysisk aktivitet. Målet med den här experimentella studien är att testa det nya verktyget utvecklat av Erik Almgren och at tvärdera om det kan bli ett gällande verktyg för att tillförlitligt kunna bedöma rörlig axel styrka. Fjorton friska och unga testpersoner deltog i den här studien. Efter att ha satt fast det nya verktyget på den vänstra handleden utfördes tre olika test: Fullt rörelseområde, statiska mätningar och dynamiska mätningar. Tre försök gjordes av varje test med återhämtningspauser på 30 sekunder. Resultatet av studien visade att de Statiska mätningarna liknade de som erhållitsi föregående studier för både vinklar och kraft. För första gången inkluderade studien Dynamiska mätningar av moment i axelleden. Största dynamiska momentet var i genomsnitt 6,43 N·m ± 1.00 N·m för kvinnorna och 7.90N·m ±2.33 N·m för männen. Detta värde är 6% lägre än populationens genomsnittliga maximala resultat för statiskt moment vilket överensstämmer med det inverterade förhållandet mellan kraft och hastighet. Möjligheten att kunna använda detta nya verktyg utanför ett biomekanisk tlaboratorium har bevisats, men ytterligare forskning måste göras för att validera vinklar och mätningar av försökspersoner. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-255658TRITA-CBH-GRU ; 2019:074application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Others
|
sources |
NDLTD |
topic |
Shoulder Abduction Moment Dynamic measurements Healthy Patients Axel Abduktion Moment Dynamiska mätningar Friska patienter Medical Laboratory and Measurements Technologies Medicinsk laboratorie- och mätteknik |
spellingShingle |
Shoulder Abduction Moment Dynamic measurements Healthy Patients Axel Abduktion Moment Dynamiska mätningar Friska patienter Medical Laboratory and Measurements Technologies Medicinsk laboratorie- och mätteknik Rodríguez, Cristina Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study |
description |
The ability to maintain an independent living at higher age is closely linked to the physical function of an individual. The evaluation of the upper limbs, including the muscular strength of the shoulder, elbow or wrist has received little attention, yet arms are used in most daily tasks. The upper extremity physical performancecan be measured in several ways but none of them has the recognition to be theprimary method. The aim of this experimental study is to test the new devicedeveloped by Erik Almgren and assess whether this can be a valid tool to reliablyassess abduction shoulder strength. Fourteen healthy young subjects participated in this study. After placing in the left wrist the new device, they performed three types of tests: Full Range of Motion, Static measurements and Dynamic measurements. Three trials were done in each test with a recovery of 30 seconds. The results of the study showed that the Static measurements were similar to the ones obtained in previous studies in the past for both angles and force. For the first time, the study includes dynamic measurements of the moment of the shoulderjoint. Peak dynamic moments were found to be on average 6.43 N·m ± 1.00 N·mfor the females and 7.90 N·m ±2.33 N·m. This value is 6% lower than the test population’s average maximum static moments- result which in accordance withthe inverse relationship between force and velocity. The feasibility of this new device to be used outside a biomechanics lab has been proved, however, further research needs to be done in order to validate angles and measurements of the subjects. === Förmågan att uppehålla ett självständigt levnadssätt vid en högre ålder är näralänkat till den fysiska funktionen hos en individ. Utvärderingen av de övre armarna, däribland muskelstyrkan hos axlarna, armbågarna eller handlederna,har fått lite uppmärksamhet, trots att armarna används i många dagliga aktiviteter. Den övre extremitetens fysiska prestanda kan mätas på flera sätt men inget av dem har erkänts som det primära verktyget för underlag att kunna återvända till normal fysisk aktivitet. Målet med den här experimentella studien är att testa det nya verktyget utvecklat av Erik Almgren och at tvärdera om det kan bli ett gällande verktyg för att tillförlitligt kunna bedöma rörlig axel styrka. Fjorton friska och unga testpersoner deltog i den här studien. Efter att ha satt fast det nya verktyget på den vänstra handleden utfördes tre olika test: Fullt rörelseområde, statiska mätningar och dynamiska mätningar. Tre försök gjordes av varje test med återhämtningspauser på 30 sekunder. Resultatet av studien visade att de Statiska mätningarna liknade de som erhållitsi föregående studier för både vinklar och kraft. För första gången inkluderade studien Dynamiska mätningar av moment i axelleden. Största dynamiska momentet var i genomsnitt 6,43 N·m ± 1.00 N·m för kvinnorna och 7.90N·m ±2.33 N·m för männen. Detta värde är 6% lägre än populationens genomsnittliga maximala resultat för statiskt moment vilket överensstämmer med det inverterade förhållandet mellan kraft och hastighet. Möjligheten att kunna använda detta nya verktyg utanför ett biomekanisk tlaboratorium har bevisats, men ytterligare forskning måste göras för att validera vinklar och mätningar av försökspersoner. |
author |
Rodríguez, Cristina |
author_facet |
Rodríguez, Cristina |
author_sort |
Rodríguez, Cristina |
title |
Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study |
title_short |
Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study |
title_full |
Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study |
title_fullStr |
Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study |
title_full_unstemmed |
Measuring Shoulder Abduction in a Healthy and Young Population: A Feasibility Study |
title_sort |
measuring shoulder abduction in a healthy and young population: a feasibility study |
publisher |
KTH, Medicinteknik och hälsosystem |
publishDate |
2019 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-255658 |
work_keys_str_mv |
AT rodriguezcristina measuringshoulderabductioninahealthyandyoungpopulationafeasibilitystudy AT rodriguezcristina matningavaxelabduktionienfriskochungbefolkningengenomforbarhetsstudie |
_version_ |
1719233948784001024 |