Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance
Chromatography and extraction techniques, and also chemiluminescence have been utilized to develop new rapid and informative tools in the evaluation of long-term properties and environmental effects of polymeric materials. Methods were developed for classification of materials and for early and rapi...
Main Author: | |
---|---|
Format: | Doctoral Thesis |
Language: | English |
Published: |
KTH, Fiber- och polymerteknik
2005
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-219 http://nbn-resolving.de/urn:isbn:91-7178-097-1 |
id |
ndltd-UPSALLA1-oai-DiVA.org-kth-219 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-kth-2192013-01-08T13:06:40ZChromatography and extraction techniques for new evaluation methods of polyolefins long-term performanceengBurman, LinaKTH, Fiber- och polymerteknikStockholm : KTH2005Chemical engineeringpolymerchromatographic fingerprintinggas-chromatography – mass spectrometryGC-MSdegradable polyethyleneprooxidant systemschemiluminescenceoxidationdegradation mechanismsaccelerated ageingantioxidantstransformation productsmicrowave assisted extractionMAEsolid-phase microextractionSPMEvolatilessolid phase extractionSPEKemiteknikChemical engineeringKemiteknikChromatography and extraction techniques, and also chemiluminescence have been utilized to develop new rapid and informative tools in the evaluation of long-term properties and environmental effects of polymeric materials. Methods were developed for classification of materials and for early and rapid degradation detection. Degradable polyethylene films were classified on the basis of their incorporated prooxidant systems using chromatographic fingerprinting of carboxylic acids, the dominating type of degradation product. The fingerprints were also shown to be useful for prediction of the degradation states and evaluation of the degradation mechanisms. Classification and prediction models were obtained by Multivariate Data Analysis, where the diacids were grouped according to both their type of prooxidant system and their state of degradation. The use of total luminescence intensity (TLI) measurements was also investigated as a means of classifying films and for the early detection of degradation. Comparisons were carried out with common techniques, e.g. FTIR and DSC, after both thermal and UV oxidation. TLI gave an earlier detection of degradation and was more sensitive than carbonyl index and crystallinity measurements to relative differences in degradation between the materials. It furthermore offered complementary information regarding changes in activation energies during the course of the degradation. The results were compared with the chromatographic fingerprints. A new way to evaluate the low temperature long-term stabilisation efficiency of antioxidants was investigated. A prooxidant was used to obtain catalytic oxidation, instead of using thermal acceleration, to evaluate the stabilisation efficiency of antioxidants at low temperatures but still during reasonably short aging times. Comparisons were made between polypropylene films stabilised with primary antioxidants (Irganox 1076, Irganox 1010 and α-tocopherol) with and without the prooxidant manganese stearate at different temperatures. The relative efficiencies of the antioxidants obtained under prooxidant acceleration test correlated better than thermal acceleration test with the results of a long-term low temperature test. Additives in plastic packaging materials may affect the environment after migration from the packaging to e.g. their contents, especially if they consist of organic aqueous solutions or oils. The use of Solid-Phase Microextraction (SPME) for the specific task of extraction from an organic aqueous solution such as a simulated food or pharmaceutical solution consisting of 10 vol-% ethanol in water was investigated. Methods were developed and evaluated for extraction both with direct sampling and with headspace sampling. If the extraction method and temperature were selected to suit the concentration levels of the analytes, it was possible to quantify several degradation products simultaneously. Comparisons made with Solid Phase Extraction showed the advantage of SPME for this purpose. QC 20100929Doctoral thesis, comprehensive summaryinfo:eu-repo/semantics/doctoralThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-219urn:isbn:91-7178-097-1Trita-FPT-Report, 1652-2443 ; 2005:20application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
English |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
Chemical engineering polymer chromatographic fingerprinting gas-chromatography – mass spectrometry GC-MS degradable polyethylene prooxidant systems chemiluminescence oxidation degradation mechanisms accelerated ageing antioxidants transformation products microwave assisted extraction MAE solid-phase microextraction SPME volatiles solid phase extraction SPE Kemiteknik Chemical engineering Kemiteknik |
spellingShingle |
Chemical engineering polymer chromatographic fingerprinting gas-chromatography – mass spectrometry GC-MS degradable polyethylene prooxidant systems chemiluminescence oxidation degradation mechanisms accelerated ageing antioxidants transformation products microwave assisted extraction MAE solid-phase microextraction SPME volatiles solid phase extraction SPE Kemiteknik Chemical engineering Kemiteknik Burman, Lina Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
description |
Chromatography and extraction techniques, and also chemiluminescence have been utilized to develop new rapid and informative tools in the evaluation of long-term properties and environmental effects of polymeric materials. Methods were developed for classification of materials and for early and rapid degradation detection. Degradable polyethylene films were classified on the basis of their incorporated prooxidant systems using chromatographic fingerprinting of carboxylic acids, the dominating type of degradation product. The fingerprints were also shown to be useful for prediction of the degradation states and evaluation of the degradation mechanisms. Classification and prediction models were obtained by Multivariate Data Analysis, where the diacids were grouped according to both their type of prooxidant system and their state of degradation. The use of total luminescence intensity (TLI) measurements was also investigated as a means of classifying films and for the early detection of degradation. Comparisons were carried out with common techniques, e.g. FTIR and DSC, after both thermal and UV oxidation. TLI gave an earlier detection of degradation and was more sensitive than carbonyl index and crystallinity measurements to relative differences in degradation between the materials. It furthermore offered complementary information regarding changes in activation energies during the course of the degradation. The results were compared with the chromatographic fingerprints. A new way to evaluate the low temperature long-term stabilisation efficiency of antioxidants was investigated. A prooxidant was used to obtain catalytic oxidation, instead of using thermal acceleration, to evaluate the stabilisation efficiency of antioxidants at low temperatures but still during reasonably short aging times. Comparisons were made between polypropylene films stabilised with primary antioxidants (Irganox 1076, Irganox 1010 and α-tocopherol) with and without the prooxidant manganese stearate at different temperatures. The relative efficiencies of the antioxidants obtained under prooxidant acceleration test correlated better than thermal acceleration test with the results of a long-term low temperature test. Additives in plastic packaging materials may affect the environment after migration from the packaging to e.g. their contents, especially if they consist of organic aqueous solutions or oils. The use of Solid-Phase Microextraction (SPME) for the specific task of extraction from an organic aqueous solution such as a simulated food or pharmaceutical solution consisting of 10 vol-% ethanol in water was investigated. Methods were developed and evaluated for extraction both with direct sampling and with headspace sampling. If the extraction method and temperature were selected to suit the concentration levels of the analytes, it was possible to quantify several degradation products simultaneously. Comparisons made with Solid Phase Extraction showed the advantage of SPME for this purpose. === QC 20100929 |
author |
Burman, Lina |
author_facet |
Burman, Lina |
author_sort |
Burman, Lina |
title |
Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
title_short |
Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
title_full |
Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
title_fullStr |
Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
title_full_unstemmed |
Chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
title_sort |
chromatography and extraction techniques for new evaluation methods of polyolefins long-term performance |
publisher |
KTH, Fiber- och polymerteknik |
publishDate |
2005 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-219 http://nbn-resolving.de/urn:isbn:91-7178-097-1 |
work_keys_str_mv |
AT burmanlina chromatographyandextractiontechniquesfornewevaluationmethodsofpolyolefinslongtermperformance |
_version_ |
1716508918423748608 |