Integrating Heat Pumps into Smart Grids
Transforming our energy system towards 100% renewable energy sources requires radical changes across all energy sectors. Heat pumps as efficient heat generation technology link the electricity and heat sector. From 2010 to 2015 between 750,000 and 800,000 heat pumps have been sold every year across...
Main Author: | |
---|---|
Format: | Doctoral Thesis |
Language: | English |
Published: |
KTH, Energiteknik
2017
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-214444 http://nbn-resolving.de/urn:isbn:978-91-7729-503-7 |
id |
ndltd-UPSALLA1-oai-DiVA.org-kth-214444 |
---|---|
record_format |
oai_dc |
collection |
NDLTD |
language |
English |
format |
Doctoral Thesis |
sources |
NDLTD |
topic |
Energy Engineering Energiteknik |
spellingShingle |
Energy Engineering Energiteknik Fischer, David Integrating Heat Pumps into Smart Grids |
description |
Transforming our energy system towards 100% renewable energy sources requires radical changes across all energy sectors. Heat pumps as efficient heat generation technology link the electricity and heat sector. From 2010 to 2015 between 750,000 and 800,000 heat pumps have been sold every year across Europe. Those heat pumps, when connected to thermal storage or using the buildings’ thermal inertia, have the potential to offer demand flexibility to the power system. In a renewable, interconnected and to a large extend decentralised energy system - the smart grid - heat pumps can be operated according to the need of the electric power system. This might impact heat pump system design, controls and operation, which is investigated in this thesis. The main objective of this thesis is to add knowledge and suggest methods to facilitate the transition towards a renewable and smart energy system, in which heat pump systems and their flexibility are used and designed in an optimal way. Therefore this thesis investigates the integration of heat pumps in a smart grid on three different system boundary levels. On each boundary level the focus is on different aspects and different methods are used. On the highest boundary level, the integration of heat pumps into a smart grid and the resulting requirements for heat pump system design are studied. Results of a literature study show, that currently discussed applications of heat pumps in a smart grid focus on the provision of ancillary services, the integration of renewable energy sources, and the operation under time variable electricity prices. Integrating heat pumps into the power system can be achieved by direct, indirect and agent based control strategies. The next level of investigation covers the aggregation of heat pumps into pools. For this purpose a stochastic bottom-up model for heat pump pools has been developed. This model accounts for the diversity of buildings, heat pump systems and occupants. Results of a simulation study of a heat pump pool highlight the fact that flexibility of heat pumps is not constant and is changing during the course of the day and year. A characteristic response of a heat pump pool towards direct load control signals is identified and shows three characteristic phases 1) charging/ activation phase, 2) steady state phase, 3) discharging/regeneration phase. It is found that the duration of the control signal and the load shift strategy implemented in the heat pump systems are decisive for flexibility. Further it is shown that flexibility might come at the cost of efficiency of the local heat pump systems. On the level of individual buildings this thesis explores to which extent the sizing of heat pumps, storage and back-up heater as well as system controls have to be adjusted when integrating heat pumps into a smart grid. Results of a structural optimisation study, targeting to minimise total cost of ownership, show that sizing of the heat pump unit and the electric back-up heater remain almost unchanged when PV and time variable electricity prices are introduced. However an increase in storage capacity is beneficial to profit from time variable prices or onsite photovoltaic (PV). It showed that the ways heat pumps and storages are sized in Germany today provided sufficient storage capacity for most of the investigated scenarios. Furthermore increasing storage leads to diminishing returns as investment costs and system losses increase with increasing storage size. This leads to the conclusion that local heat pump system efficiency as well as flexibility requirements of the power system should be considered, when designing heat pump systems. Improving the controls shows great potential for increasing heat pump system efficiency, reducing operation cost and scheduling heat pump operation along to match the requirements from the power system. A dynamic building simulation study, where rule-based, predictive rule-based and model predictive control approaches were compared, reveals that the use of model predictive controls can reduce annual electricity cost and increase PV self-consumption significantly, compared to tailored rule-based and predictive rule-based control approaches. When deciding upon a control strategy the following should be taken into account: complexity of design, robustness against changes in external conditions and computational resources. It is shown that operating heat pumps in a smart grid changes operating hours, temperatures, on/off cycles and seasonal performance compared to today’s heatdriven operation. It is shown that the goals to reduce operating cost, maximise system efficiency or increase PV self-consumption can be conflicting and are often impossible to achieve simultaneously. Not necessarily will operation in a smart grid increase the efficiency of individual systems, rather offers the possibility to increase efficiency of the overall energy system. It is found that sizing, controls and use-case are interconnected and should be considered simultaneously in the design process of heat pump systems. A goal for future research should be the design of optimum flexible heat pump systems, where the heat pump unit, the building, the hydraulic system, heat distribution, storage and controls are designed optimally for the flexibility requirements of both the end-users and the power system. |
author |
Fischer, David |
author_facet |
Fischer, David |
author_sort |
Fischer, David |
title |
Integrating Heat Pumps into Smart Grids |
title_short |
Integrating Heat Pumps into Smart Grids |
title_full |
Integrating Heat Pumps into Smart Grids |
title_fullStr |
Integrating Heat Pumps into Smart Grids |
title_full_unstemmed |
Integrating Heat Pumps into Smart Grids |
title_sort |
integrating heat pumps into smart grids |
publisher |
KTH, Energiteknik |
publishDate |
2017 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-214444 http://nbn-resolving.de/urn:isbn:978-91-7729-503-7 |
work_keys_str_mv |
AT fischerdavid integratingheatpumpsintosmartgrids |
_version_ |
1718538440614608896 |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-kth-2144442017-09-19T05:22:25ZIntegrating Heat Pumps into Smart GridsengFischer, DavidKTH, Energiteknik2017Energy EngineeringEnergiteknikTransforming our energy system towards 100% renewable energy sources requires radical changes across all energy sectors. Heat pumps as efficient heat generation technology link the electricity and heat sector. From 2010 to 2015 between 750,000 and 800,000 heat pumps have been sold every year across Europe. Those heat pumps, when connected to thermal storage or using the buildings’ thermal inertia, have the potential to offer demand flexibility to the power system. In a renewable, interconnected and to a large extend decentralised energy system - the smart grid - heat pumps can be operated according to the need of the electric power system. This might impact heat pump system design, controls and operation, which is investigated in this thesis. The main objective of this thesis is to add knowledge and suggest methods to facilitate the transition towards a renewable and smart energy system, in which heat pump systems and their flexibility are used and designed in an optimal way. Therefore this thesis investigates the integration of heat pumps in a smart grid on three different system boundary levels. On each boundary level the focus is on different aspects and different methods are used. On the highest boundary level, the integration of heat pumps into a smart grid and the resulting requirements for heat pump system design are studied. Results of a literature study show, that currently discussed applications of heat pumps in a smart grid focus on the provision of ancillary services, the integration of renewable energy sources, and the operation under time variable electricity prices. Integrating heat pumps into the power system can be achieved by direct, indirect and agent based control strategies. The next level of investigation covers the aggregation of heat pumps into pools. For this purpose a stochastic bottom-up model for heat pump pools has been developed. This model accounts for the diversity of buildings, heat pump systems and occupants. Results of a simulation study of a heat pump pool highlight the fact that flexibility of heat pumps is not constant and is changing during the course of the day and year. A characteristic response of a heat pump pool towards direct load control signals is identified and shows three characteristic phases 1) charging/ activation phase, 2) steady state phase, 3) discharging/regeneration phase. It is found that the duration of the control signal and the load shift strategy implemented in the heat pump systems are decisive for flexibility. Further it is shown that flexibility might come at the cost of efficiency of the local heat pump systems. On the level of individual buildings this thesis explores to which extent the sizing of heat pumps, storage and back-up heater as well as system controls have to be adjusted when integrating heat pumps into a smart grid. Results of a structural optimisation study, targeting to minimise total cost of ownership, show that sizing of the heat pump unit and the electric back-up heater remain almost unchanged when PV and time variable electricity prices are introduced. However an increase in storage capacity is beneficial to profit from time variable prices or onsite photovoltaic (PV). It showed that the ways heat pumps and storages are sized in Germany today provided sufficient storage capacity for most of the investigated scenarios. Furthermore increasing storage leads to diminishing returns as investment costs and system losses increase with increasing storage size. This leads to the conclusion that local heat pump system efficiency as well as flexibility requirements of the power system should be considered, when designing heat pump systems. Improving the controls shows great potential for increasing heat pump system efficiency, reducing operation cost and scheduling heat pump operation along to match the requirements from the power system. A dynamic building simulation study, where rule-based, predictive rule-based and model predictive control approaches were compared, reveals that the use of model predictive controls can reduce annual electricity cost and increase PV self-consumption significantly, compared to tailored rule-based and predictive rule-based control approaches. When deciding upon a control strategy the following should be taken into account: complexity of design, robustness against changes in external conditions and computational resources. It is shown that operating heat pumps in a smart grid changes operating hours, temperatures, on/off cycles and seasonal performance compared to today’s heatdriven operation. It is shown that the goals to reduce operating cost, maximise system efficiency or increase PV self-consumption can be conflicting and are often impossible to achieve simultaneously. Not necessarily will operation in a smart grid increase the efficiency of individual systems, rather offers the possibility to increase efficiency of the overall energy system. It is found that sizing, controls and use-case are interconnected and should be considered simultaneously in the design process of heat pump systems. A goal for future research should be the design of optimum flexible heat pump systems, where the heat pump unit, the building, the hydraulic system, heat distribution, storage and controls are designed optimally for the flexibility requirements of both the end-users and the power system. Doctoral thesis, comprehensive summaryinfo:eu-repo/semantics/doctoralThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-214444urn:isbn:978-91-7729-503-7TRITA-REFR, 1102-0245 ; 17/03application/pdfinfo:eu-repo/semantics/openAccess |