Noise reduction solutions for compact dishwasher

Electrolux are currently developing a new kind of compact dishwasher, distinctly different from conventional dishwashers. A key concern that emerged through the development process was noise. The sound was characterized as loud and annoying. The goal of this thesis was to develop a mechanical design...

Full description

Bibliographic Details
Main Author: Haglund, Philip
Format: Others
Language:English
Published: KTH, Maskinkonstruktion (Inst.) 2013
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-157658
id ndltd-UPSALLA1-oai-DiVA.org-kth-157658
record_format oai_dc
collection NDLTD
language English
format Others
sources NDLTD
description Electrolux are currently developing a new kind of compact dishwasher, distinctly different from conventional dishwashers. A key concern that emerged through the development process was noise. The sound was characterized as loud and annoying. The goal of this thesis was to develop a mechanical design solution that would guarantee a noise level below 55 dBA. Initial tests reaffirmed the concern regarding noise. Noise was prevalent and the sound pressure level ranging from 58,8 to 59,8 was considered intolerable. Tests were performed in an acoustic lab to determine vibration source and noise factors. The pump was identified as the vibration source and the suspension was identified as the major noise factor. The rubber flange supporting the pump was fastened with screws. Loose screws failed to keep the pump in place whilst tight screws deformed the flange and pushed the pump against an adjacent plastic feature. There was a perceptible increase of 4,5 dBA when the two were in contact, and a palpable increase of 9,4 dBA when they were hitting each other. Metal spacers were the most reliable and effective solution for lowering the noise. Placed between the flange and the screws, the spacers kept the rubber flange from deforming and prevented it from hitting the adjacent feature. Metal spacers reduced the noise level from 60,6 to 51,3 dBA, a difference perceived half as loud. The efficiency of the metal washer was demonstrated in field tests, during which no complaints were made on the noise level. Pumps and dishwashers were tested in a hydraulic lab to determine operating point and best efficiency point. Pump compatibility determines performance and reliability, as poor operating conditions cause additional vibration, noise and wear. Tests concluded that the hydraulic performance and overall efficiency was poor. The operating point ranged from 4 to 8%, far below the best efficiency point of 15%. Pumps were put through a reliability test, none of which met the company requirement for longevity. Conclusions from the research were used to develop a new suspension concept. The design enabled vibrations to be absorbed and ensured infallible assembly. Rubber straps stretch between the pump and three surrounding support rods and provide supported during operation. The elastic suspension counteracts pump motion and dislocation. A prototype was manufactured to demonstrate the principle function and design. === Electrolux håller på att utveckla en ny typ av diskbänksdiskmaskin som skiljer sig från konventionella diskmaskiner. Ett problem som framkom under utvecklingsarbetet var ljudnivån som ansågs ovanligt hög och störande. Målet med denna avhandling var att utveckla en mekanisk konstruktionslösning som kunde garanterade en ljudnivå under 55 dBA. Tidiga tester bekräftade problematiken kring ljudnivån. Oljudet var påtagligt och ljudtrycksnivån varierade mellan 58,8 och 59,8 dBa, vilket ansågs oacceptabelt. Tester gjordes i ett akustiskt laboratorium för att fastställa vibrationskällan och ljudsfaktorer. Pumpen identifierades som vibrationskälla och upphängningen identifierades som en viktig ljudsfaktor. Gummiflänsen som höll pumpen på plats fästes med skruvar. Lösa skruvar misslyckades med att hålla pumpen på plats medan åtsittande skruvar deformerade flänsen och tryckte pumpen mot en intilliggande plastdetalj. Ljudet ökade märkbart med 4,5 dBA när de två trycktes mot varandra. När de slogs mot varande blev det en påtaglig ökning med 9,4 dBA. Metalldistanser var den mest tillförlitliga och effektiva lösningen för att dämpa ljudet. De placerades mellan flänsen och skruvarna för att förhindra flänsen från att deformeras och träffa den intilliggande plastdetaljen. Ljudnivån minskade från 60,6 till 51,3 dBA. För en människa upplevs skillnaden som en halvering av ljudnivån. Metalldistansernas effektivitet påvisades i fältprover, där inga klagomål gjordes på ljudnivån. Pumpar och diskmaskiner testades i ett hydrauliklaboratorium för att bestämma driftspunkten och bästa verkningsgradspunkten. Pumpkompatibilitet avgör prestanda och tillförlitlighet, eftersom dåliga driftsförhållanden orsakar ytterligare vibrationer, ljud och slitage. Slutsatsen av testerna var att den hydrauliska prestanda och totala effektiviteten var låg. Driftspunkten varierade från 4 till 8 %, långt under den bästa verkningsgradspunkten kring 15 %. Pumpar sattes på prov i ett tillförlitlighetstest. Ingen av de pumpar som provades uppfyllde kravet på livslängd. En konceptuell pumpupphängning utvecklades baserad på slutsatserna från forskningen. Den var utformades för att absorbera vibrationer och garantera korrekt montering. Pumpen hålls på plats med hjälp av gummiband istället för en gummifläns. Den elastiska upphängningen motverkar pumpens rörelser och förhindrar att den förskjuts. En prototyp tillverkades för att demonstrera konceptets funktion och design.
author Haglund, Philip
spellingShingle Haglund, Philip
Noise reduction solutions for compact dishwasher
author_facet Haglund, Philip
author_sort Haglund, Philip
title Noise reduction solutions for compact dishwasher
title_short Noise reduction solutions for compact dishwasher
title_full Noise reduction solutions for compact dishwasher
title_fullStr Noise reduction solutions for compact dishwasher
title_full_unstemmed Noise reduction solutions for compact dishwasher
title_sort noise reduction solutions for compact dishwasher
publisher KTH, Maskinkonstruktion (Inst.)
publishDate 2013
url http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-157658
work_keys_str_mv AT haglundphilip noisereductionsolutionsforcompactdishwasher
AT haglundphilip ljudreducerandeatgarderforbankdiskmaskin
_version_ 1718199853707689984
spelling ndltd-UPSALLA1-oai-DiVA.org-kth-1576582016-03-08T05:21:25ZNoise reduction solutions for compact dishwasherengLjudreducerande åtgärder för bänkdiskmaskinHaglund, PhilipKTH, Maskinkonstruktion (Inst.)2013Electrolux are currently developing a new kind of compact dishwasher, distinctly different from conventional dishwashers. A key concern that emerged through the development process was noise. The sound was characterized as loud and annoying. The goal of this thesis was to develop a mechanical design solution that would guarantee a noise level below 55 dBA. Initial tests reaffirmed the concern regarding noise. Noise was prevalent and the sound pressure level ranging from 58,8 to 59,8 was considered intolerable. Tests were performed in an acoustic lab to determine vibration source and noise factors. The pump was identified as the vibration source and the suspension was identified as the major noise factor. The rubber flange supporting the pump was fastened with screws. Loose screws failed to keep the pump in place whilst tight screws deformed the flange and pushed the pump against an adjacent plastic feature. There was a perceptible increase of 4,5 dBA when the two were in contact, and a palpable increase of 9,4 dBA when they were hitting each other. Metal spacers were the most reliable and effective solution for lowering the noise. Placed between the flange and the screws, the spacers kept the rubber flange from deforming and prevented it from hitting the adjacent feature. Metal spacers reduced the noise level from 60,6 to 51,3 dBA, a difference perceived half as loud. The efficiency of the metal washer was demonstrated in field tests, during which no complaints were made on the noise level. Pumps and dishwashers were tested in a hydraulic lab to determine operating point and best efficiency point. Pump compatibility determines performance and reliability, as poor operating conditions cause additional vibration, noise and wear. Tests concluded that the hydraulic performance and overall efficiency was poor. The operating point ranged from 4 to 8%, far below the best efficiency point of 15%. Pumps were put through a reliability test, none of which met the company requirement for longevity. Conclusions from the research were used to develop a new suspension concept. The design enabled vibrations to be absorbed and ensured infallible assembly. Rubber straps stretch between the pump and three surrounding support rods and provide supported during operation. The elastic suspension counteracts pump motion and dislocation. A prototype was manufactured to demonstrate the principle function and design. Electrolux håller på att utveckla en ny typ av diskbänksdiskmaskin som skiljer sig från konventionella diskmaskiner. Ett problem som framkom under utvecklingsarbetet var ljudnivån som ansågs ovanligt hög och störande. Målet med denna avhandling var att utveckla en mekanisk konstruktionslösning som kunde garanterade en ljudnivå under 55 dBA. Tidiga tester bekräftade problematiken kring ljudnivån. Oljudet var påtagligt och ljudtrycksnivån varierade mellan 58,8 och 59,8 dBa, vilket ansågs oacceptabelt. Tester gjordes i ett akustiskt laboratorium för att fastställa vibrationskällan och ljudsfaktorer. Pumpen identifierades som vibrationskälla och upphängningen identifierades som en viktig ljudsfaktor. Gummiflänsen som höll pumpen på plats fästes med skruvar. Lösa skruvar misslyckades med att hålla pumpen på plats medan åtsittande skruvar deformerade flänsen och tryckte pumpen mot en intilliggande plastdetalj. Ljudet ökade märkbart med 4,5 dBA när de två trycktes mot varandra. När de slogs mot varande blev det en påtaglig ökning med 9,4 dBA. Metalldistanser var den mest tillförlitliga och effektiva lösningen för att dämpa ljudet. De placerades mellan flänsen och skruvarna för att förhindra flänsen från att deformeras och träffa den intilliggande plastdetaljen. Ljudnivån minskade från 60,6 till 51,3 dBA. För en människa upplevs skillnaden som en halvering av ljudnivån. Metalldistansernas effektivitet påvisades i fältprover, där inga klagomål gjordes på ljudnivån. Pumpar och diskmaskiner testades i ett hydrauliklaboratorium för att bestämma driftspunkten och bästa verkningsgradspunkten. Pumpkompatibilitet avgör prestanda och tillförlitlighet, eftersom dåliga driftsförhållanden orsakar ytterligare vibrationer, ljud och slitage. Slutsatsen av testerna var att den hydrauliska prestanda och totala effektiviteten var låg. Driftspunkten varierade från 4 till 8 %, långt under den bästa verkningsgradspunkten kring 15 %. Pumpar sattes på prov i ett tillförlitlighetstest. Ingen av de pumpar som provades uppfyllde kravet på livslängd. En konceptuell pumpupphängning utvecklades baserad på slutsatserna från forskningen. Den var utformades för att absorbera vibrationer och garantera korrekt montering. Pumpen hålls på plats med hjälp av gummiband istället för en gummifläns. Den elastiska upphängningen motverkar pumpens rörelser och förhindrar att den förskjuts. En prototyp tillverkades för att demonstrera konceptets funktion och design. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-157658MMK 2013:88 IDE 123application/pdfinfo:eu-repo/semantics/openAccess