Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education

The sensitivity for observing physiological processes makes nuclear imaging an important tool in medical diagnostics. Different types of nuclear imaging modalities, with emphasis on the software components and image reconstructions, are presented in this thesis:  the Cardiotom for myocardial heart s...

Full description

Bibliographic Details
Main Author: Valastyán, Iván
Format: Doctoral Thesis
Language:English
Published: KTH, Medicinsk teknik 2010
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-12069
id ndltd-UPSALLA1-oai-DiVA.org-kth-12069
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-kth-120692013-01-08T13:06:24ZSoftware Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and EducationengValastyán, IvánKTH, Medicinsk teknikStockholm : KTH2010Medical technologyMedicinsk teknikThe sensitivity for observing physiological processes makes nuclear imaging an important tool in medical diagnostics. Different types of nuclear imaging modalities, with emphasis on the software components and image reconstructions, are presented in this thesis:  the Cardiotom for myocardial heart studies at the Karolinska University Hospital, the small animal Positron Emission Tomograph (PET) scanners for research and the SPECT, PET, spiral CT and Cardiotom demonstrators for the Royal Institute of Technology medical imaging laboratory. A modular and unified software platform has been developed for data representation, acquisition, visualization, reconstruction and presentation of the programs of the imaging devices mentioned above. The high performance 3D ML-EM and OS-EM iterative image reconstruction methods are implemented both on Cardiotom and miniPET scanners. As a result, the in-slice resolution of the first two prototypes of the Cardiotom today is the same as the formerly used filtered back-projection, however the in-depth resolution is considerably increased. Another improvement due to the new software is the shorter time that is required for data acquisition and image reconstruction. The new electronics with the newly developed software ensure images for medical diagnosis within 10 minutes from the start ofthe examination. The first system from the standardized production of the Cardiotom cameras is in the test phase. The performance parameters (sensitivity, spatial and energy resolution, coincidence time resolution) of the full ring mini PET camera are comparable to other small animal PETsystems. QC20100721Doctoral thesis, comprehensive summaryinfo:eu-repo/semantics/doctoralThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-12069Trita-STH : report, 1653-3836 ; 2010:1application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Doctoral Thesis
sources NDLTD
topic Medical technology
Medicinsk teknik
spellingShingle Medical technology
Medicinsk teknik
Valastyán, Iván
Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education
description The sensitivity for observing physiological processes makes nuclear imaging an important tool in medical diagnostics. Different types of nuclear imaging modalities, with emphasis on the software components and image reconstructions, are presented in this thesis:  the Cardiotom for myocardial heart studies at the Karolinska University Hospital, the small animal Positron Emission Tomograph (PET) scanners for research and the SPECT, PET, spiral CT and Cardiotom demonstrators for the Royal Institute of Technology medical imaging laboratory. A modular and unified software platform has been developed for data representation, acquisition, visualization, reconstruction and presentation of the programs of the imaging devices mentioned above. The high performance 3D ML-EM and OS-EM iterative image reconstruction methods are implemented both on Cardiotom and miniPET scanners. As a result, the in-slice resolution of the first two prototypes of the Cardiotom today is the same as the formerly used filtered back-projection, however the in-depth resolution is considerably increased. Another improvement due to the new software is the shorter time that is required for data acquisition and image reconstruction. The new electronics with the newly developed software ensure images for medical diagnosis within 10 minutes from the start ofthe examination. The first system from the standardized production of the Cardiotom cameras is in the test phase. The performance parameters (sensitivity, spatial and energy resolution, coincidence time resolution) of the full ring mini PET camera are comparable to other small animal PETsystems. === QC20100721
author Valastyán, Iván
author_facet Valastyán, Iván
author_sort Valastyán, Iván
title Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education
title_short Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education
title_full Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education
title_fullStr Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education
title_full_unstemmed Software Solutions for Nuclear Imaging Systems in Cardiology, Small Animal Research and Education
title_sort software solutions for nuclear imaging systems in cardiology, small animal research and education
publisher KTH, Medicinsk teknik
publishDate 2010
url http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-12069
work_keys_str_mv AT valastyanivan softwaresolutionsfornuclearimagingsystemsincardiologysmallanimalresearchandeducation
_version_ 1716508899903799296