Mekanisk integration av en IR-detektor i en Stirlingkylare

The master thesis “Mechanical Integration of an IR-detector in a Micro Cooler” has been performed at FLIR Systems AB in Danderyd. FLIR Systems is a world leader in the design, manufacture and marketing of thermal imaging camera systems. The thesis project is divided into to two areas, Production Met...

Full description

Bibliographic Details
Main Author: Gibson, Camilla
Format: Others
Language:Swedish
Published: KTH, Maskinkonstruktion (Inst.) 2008
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-100217
Description
Summary:The master thesis “Mechanical Integration of an IR-detector in a Micro Cooler” has been performed at FLIR Systems AB in Danderyd. FLIR Systems is a world leader in the design, manufacture and marketing of thermal imaging camera systems. The thesis project is divided into to two areas, Production Method and Noise. The Production Method concerns the positioning of a detector on the cold finger within the IRcamera. The detector has to be positiond with very high accuracy at the center of the cold finger, so it can be placed in line with the optical axis to avoid movement of the picture during zooming. The positioning of the detector is at present done with the help of specially designed guides on a plate on top of the cold finger. The design workes well but the special machining needed for this plate is very expensive. The goal concerning the production method was to derive a new more cost effective method for the assembling and positioning of the detector on the cold finger by replacing the guides on the plate with a reusable equipment or some other alignement operation. Several concept ideas have been generated with the help of concept generation methods in the form of concept classification trees and concept combinational tables. Two of these concepts were selected to be further refined. The selection was done with the help of a concept scoring method and a concept evaluation meeting. In the first concept the detector is positioned with the help of a microscope and in the second with the help of an external fixture. A prototype of the fixture has been manufactured and an evaluation was done concerning function and price aspects. This showed that the positioning of the detector will be good and the assemblers were positive towards the fixture and the handling of it. The investment of the fixture will be returned compared to the plate with the guides after only four assembled detectors. The Noise part of the thesis concerns a disturbance that sometimes can be seen in the picture. This disturbance, here called flicker, seem to be generated by the Stirling micro cooler since the frequency of the flicker follows the frequency of the cooler. The cause of this flicker is unknown despite numerous of studies. The goal concerning the noise was to do studies in order to confirm or refute some hypothesis. Experiments, simulations and calculations have been done to analyse the deformations in the detector caused by pressure pulsations and the effects on the detector by vibrations of the cold finger caused by the Stirling micro cooler. However these studies did not give a clear conclution to the cause of the flicker and therefore further studies have to be done. === Examensarbetet ”Mekanisk integration av en IR-detektor i en Stirlingkylare” har utförts på FLIR Systems AB i Danderyd. FLIR Systems designar, tillverkar och säljer värmekamerasystem. Examensarbetet är uppdelat i två delar, Produktionsmetod och Störningar. Produktionsmetoden rör positioneringen av en detektor på det så kallade kalla fingret, som ingår i IR-kameran. Detektorn måste positioneras mycket noggrant så att den sedan kan placeras med centrum i den optiska axeln, vilket gör att bilden ligger stilla under zoomning. Positioneringen av detektorn görs idag med hjälp av specialdesignade styrningar som sitter på en platta på toppen av det kalla fingret. Denna metod fungerar bra, men det är mycket dyrt att tillverka dessa plattor. Målet för detta examensarbete med avseende på produktionsmetoden var att ta fram en ny mer kostnadseffektiv metod med vilken man kan montera och positionera detektorn på det kalla fingret. Ett flertal konceptidéer togs fram med hjälp av olika konceptgenereringsmetoder så som klassificeringsträd och kombinationstabeller. Två av dessa koncept valdes ut för att vidareutvecklas. Valet av dessa koncept gjordes med hjälp av en konceptvalsmetod och ett konceptutvärderingsmöte. Det ena konceptet går ut på att positionera detektorn med hjälp av bland annat ett mikroskop. Det andra konceptet är en extern fixtur på vilken det finns styrytor att positionera detektorn efter. En prototyp av fixturen har tagits fram och utvärderats med avseende på funktion och kostnad. Detta visade att positioneringen av detektorn blev god. Fixturen och handhavandet av denna fick även ett positivt utlåtande av montörerna. Fixturen tjänas prismässigt in, i jämförelse med dagens platta, efter endast fyra detektormonteringar. Den andra delen av examensarbetet behandlar de störningar som ibland uppträder i bilden. Dessa störningar, här kallade flicker, tycks genereras av Stirlingkylaren då frekvensen hos flickret följer kylmaskinens frekvens. Orsaken till detta flicker är ännu okänt trots flertalet undersökningar. Målet för examensarbetet med avseende på störningarna var att genomföra ett par studier för att kunna avfärda eller bekräfta några av teorierna bakom uppkomsten av störningarna. Experiment, simuleringar och beräkningar har gjorts för att undersöka deformationerna i detektorn som en följd av tryckpulsationer i det kalla fingret och vibrationer i detta orsakade av Stirlingkylaren. Dessa studier kunde inte entydigt påvisa orsaken till flickret utan vidare undersökningar måste göras.