Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler
SOMAS Instrument AB is a valve manufacturer in Säffle that mainly produces butterfly valves, ball segment valves and ball valves. After the manufacturing process and before the valve is to be delivered to the customer, tests are performed to verify that the valve is acceptable. The valve testing mac...
Main Authors: | , |
---|---|
Format: | Others |
Language: | Swedish |
Published: |
Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013)
2021
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-86274 |
id |
ndltd-UPSALLA1-oai-DiVA.org-kau-86274 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-kau-862742021-10-21T05:29:55ZStatistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventilersweStatistical analysis of valve testing data : Analysis and visualization of valve testing data for butterfly valves, ball segment valves and ball valves.Larsen, AdamMartinsson, KarlKarlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013)2021Mechanical EngineeringMaskinteknikSOMAS Instrument AB is a valve manufacturer in Säffle that mainly produces butterfly valves, ball segment valves and ball valves. After the manufacturing process and before the valve is to be delivered to the customer, tests are performed to verify that the valve is acceptable. The valve testing machine then gathers, and outputs data based on these tests onto data files. As SOMAS currently makes no usage of this data in their production, this thesis has analyzed and evaluated which conclusions could be made with regards to the valves’ construction and production processes, and what may need to be improved. To visualize the data more easily, it was first imported into Excel, where it was used as a basis for various diagrams. The results were evaluated and discussed with help from the staff at SOMAS to see what possible conclusions could be made and what reasonable explanations there were for the results. The most obvious conclusion that could be made was related to the XML files themselves. To make further analysis of the XML files possible in future quality related work, their layout would need to be standardized and improved in various ways. The ball segment valves were overrepresented within their seat tests, meaning that their sealing construction may need to be reviewed. Furthermore, there were some apparent problems with the valves testing machines themselves, as they sometimes were unable to press heavier balls in larger ball valves all the way up to the seat, leading to unreliable data. There is also no system in place to counteract air being left in the valves, possibly leading to many failed tests which show to fault in the valves themselves. SOMAS Ventiler AB är en ventiltillverkare i Säffle som främst tillverkar vridspjällventiler, kalottventiler och kulventiler. Efter tillverkning och inför att ventilerna ska skickas ut till kund genomförs så kallade provtryckningar för att verifiera att ventilen är godtagbar enligt standard. Provtryckningsmaskinerna som genomför dessa skriver efter testet ut vissa data i lätthanterliga datafiler. Då SOMAS i nuläget inte har någon återkoppling på denna data har detta arbete försökt analysera och utvärdera vilka slutsatser som kan dras kopplat till ventilernas konstruktion och produktion, och vad SOMAS kan behöva förbättra. För att lättare kunna visualisera data lästes den först in i Excel, där den senare användes som underlag till diverse diagram. Resultatet utvärderades och diskuterades med personal på SOMAS för att se vilka eventuella slutsatser och rimliga förklaringar som fanns till resultatet. Den tydligaste slutsats som kunde dras var relaterad till XML-filerna och deras upplägg. För att SOMAS vidare ska kunna analysera XML-filerna i sitt kvalitets arbete kommer deras upplägg behöva standardiseras och på olika sätt förbättras. Dessutom kan det konstateras att kalottventilerna av flera olika anledningar är väldigt överrepresenterade när det gäller underkända sätestester, vilket betyder att säteskonstruktionen kan behöva ses över. Vidare kan problem ses hos provtryckarmaskinerna i sig, då de kan ha svårt att trycka kulventilernas kula mot sätet och det inte finns något system för att motverka luft som ligger kvar i ventilerna innan testerna. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-86274application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
Swedish |
format |
Others
|
sources |
NDLTD |
topic |
Mechanical Engineering Maskinteknik |
spellingShingle |
Mechanical Engineering Maskinteknik Larsen, Adam Martinsson, Karl Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
description |
SOMAS Instrument AB is a valve manufacturer in Säffle that mainly produces butterfly valves, ball segment valves and ball valves. After the manufacturing process and before the valve is to be delivered to the customer, tests are performed to verify that the valve is acceptable. The valve testing machine then gathers, and outputs data based on these tests onto data files. As SOMAS currently makes no usage of this data in their production, this thesis has analyzed and evaluated which conclusions could be made with regards to the valves’ construction and production processes, and what may need to be improved. To visualize the data more easily, it was first imported into Excel, where it was used as a basis for various diagrams. The results were evaluated and discussed with help from the staff at SOMAS to see what possible conclusions could be made and what reasonable explanations there were for the results. The most obvious conclusion that could be made was related to the XML files themselves. To make further analysis of the XML files possible in future quality related work, their layout would need to be standardized and improved in various ways. The ball segment valves were overrepresented within their seat tests, meaning that their sealing construction may need to be reviewed. Furthermore, there were some apparent problems with the valves testing machines themselves, as they sometimes were unable to press heavier balls in larger ball valves all the way up to the seat, leading to unreliable data. There is also no system in place to counteract air being left in the valves, possibly leading to many failed tests which show to fault in the valves themselves. === SOMAS Ventiler AB är en ventiltillverkare i Säffle som främst tillverkar vridspjällventiler, kalottventiler och kulventiler. Efter tillverkning och inför att ventilerna ska skickas ut till kund genomförs så kallade provtryckningar för att verifiera att ventilen är godtagbar enligt standard. Provtryckningsmaskinerna som genomför dessa skriver efter testet ut vissa data i lätthanterliga datafiler. Då SOMAS i nuläget inte har någon återkoppling på denna data har detta arbete försökt analysera och utvärdera vilka slutsatser som kan dras kopplat till ventilernas konstruktion och produktion, och vad SOMAS kan behöva förbättra. För att lättare kunna visualisera data lästes den först in i Excel, där den senare användes som underlag till diverse diagram. Resultatet utvärderades och diskuterades med personal på SOMAS för att se vilka eventuella slutsatser och rimliga förklaringar som fanns till resultatet. Den tydligaste slutsats som kunde dras var relaterad till XML-filerna och deras upplägg. För att SOMAS vidare ska kunna analysera XML-filerna i sitt kvalitets arbete kommer deras upplägg behöva standardiseras och på olika sätt förbättras. Dessutom kan det konstateras att kalottventilerna av flera olika anledningar är väldigt överrepresenterade när det gäller underkända sätestester, vilket betyder att säteskonstruktionen kan behöva ses över. Vidare kan problem ses hos provtryckarmaskinerna i sig, då de kan ha svårt att trycka kulventilernas kula mot sätet och det inte finns något system för att motverka luft som ligger kvar i ventilerna innan testerna. |
author |
Larsen, Adam Martinsson, Karl |
author_facet |
Larsen, Adam Martinsson, Karl |
author_sort |
Larsen, Adam |
title |
Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
title_short |
Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
title_full |
Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
title_fullStr |
Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
title_full_unstemmed |
Statistisk analys av provtryckardata från ventiltester : Analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
title_sort |
statistisk analys av provtryckardata från ventiltester : analys och visualisering av provtryckardata för vridspjällventiler, kalottventiler och kulventiler |
publisher |
Karlstads universitet, Fakulteten för hälsa, natur- och teknikvetenskap (from 2013) |
publishDate |
2021 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:kau:diva-86274 |
work_keys_str_mv |
AT larsenadam statistiskanalysavprovtryckardatafranventiltesteranalysochvisualiseringavprovtryckardataforvridspjallventilerkalottventilerochkulventiler AT martinssonkarl statistiskanalysavprovtryckardatafranventiltesteranalysochvisualiseringavprovtryckardataforvridspjallventilerkalottventilerochkulventiler AT larsenadam statisticalanalysisofvalvetestingdataanalysisandvisualizationofvalvetestingdataforbutterflyvalvesballsegmentvalvesandballvalves AT martinssonkarl statisticalanalysisofvalvetestingdataanalysisandvisualizationofvalvetestingdataforbutterflyvalvesballsegmentvalvesandballvalves |
_version_ |
1719490877859037184 |