The link between a good indoor climate and environmental impacts e.g. global warming and different pollution in the air is something that are important today and will certainly become more important in the future with increased energy prices and new laws. Too keep the indoor air quality within limit...

Full description

Bibliographic Details
Main Author: Gustafsson, Dennis
Format: Others
Language:English
Published: Högskolan i Gävle, Energisystem 2017
Subjects:
CO2
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-24049
id ndltd-UPSALLA1-oai-DiVA.org-hig-24049
record_format oai_dc
spelling ndltd-UPSALLA1-oai-DiVA.org-hig-240492017-06-16T05:28:24ZComparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?engGustafsson, DennisHögskolan i Gävle, Energisystem2017Carbon dioxideCO2Indoor air qualityCO2 in a training facilityEnergy EngineeringEnergiteknikThe link between a good indoor climate and environmental impacts e.g. global warming and different pollution in the air is something that are important today and will certainly become more important in the future with increased energy prices and new laws. Too keep the indoor air quality within limits is it important to have a good and competitive ventilationsystem. The ventilations function is mainly to supply fresh air and to remove polluted air from the room. It’s important that the ventilation system works as it should so that the indoor air quality is as good as possible. The lack of good ventilation can create several symptoms such as headaches, nausea, fatigue, poor concentration etc. In Sweden are ventilation control mandatory for every newly produced building and this control are repetitive usually every 3-6 years for some types of buildings.   The foundation of this thesis is from a previous degree project performed by a master’s student in 2013 named Ander Barroeta with supervision of Magnus Mattsson and Taghi Karimipanah. The thesis was to improve and design a ventilation system in two rooms at a training facility named Friskis & Svettis in Gävle so that the CO2 level did not exceed 1000 ppm.   In this thesis was the main goal to do similar measurements as the previous thesis and compare the results to see what difference air balancing has done to the ventilation system. Field measurements were performed at the training facility were the focus was on carbon dioxide but also on other parameters such as temperature, humidity and air velocity so that air exchange rate could be calculated. With these parameters can evaluations be made to see if air balancing of the ventilation system made any difference in indoor air quality.       During measurements in one of the training rooms where spinning is exercised was carbon dioxide levels up to 3300 ppm measured which is above the recommended indoor limit at 1000 ppm. If that room should be design to not exceed 1000 ppm must the air exchange rate increase from 6.3 h-1 to 35.1 h-1. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-24049application/pdfinfo:eu-repo/semantics/openAccess
collection NDLTD
language English
format Others
sources NDLTD
topic Carbon dioxide
CO2
Indoor air quality
CO2 in a training facility
Energy Engineering
Energiteknik
spellingShingle Carbon dioxide
CO2
Indoor air quality
CO2 in a training facility
Energy Engineering
Energiteknik
Gustafsson, Dennis
Comparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?
description The link between a good indoor climate and environmental impacts e.g. global warming and different pollution in the air is something that are important today and will certainly become more important in the future with increased energy prices and new laws. Too keep the indoor air quality within limits is it important to have a good and competitive ventilationsystem. The ventilations function is mainly to supply fresh air and to remove polluted air from the room. It’s important that the ventilation system works as it should so that the indoor air quality is as good as possible. The lack of good ventilation can create several symptoms such as headaches, nausea, fatigue, poor concentration etc. In Sweden are ventilation control mandatory for every newly produced building and this control are repetitive usually every 3-6 years for some types of buildings.   The foundation of this thesis is from a previous degree project performed by a master’s student in 2013 named Ander Barroeta with supervision of Magnus Mattsson and Taghi Karimipanah. The thesis was to improve and design a ventilation system in two rooms at a training facility named Friskis & Svettis in Gävle so that the CO2 level did not exceed 1000 ppm.   In this thesis was the main goal to do similar measurements as the previous thesis and compare the results to see what difference air balancing has done to the ventilation system. Field measurements were performed at the training facility were the focus was on carbon dioxide but also on other parameters such as temperature, humidity and air velocity so that air exchange rate could be calculated. With these parameters can evaluations be made to see if air balancing of the ventilation system made any difference in indoor air quality.       During measurements in one of the training rooms where spinning is exercised was carbon dioxide levels up to 3300 ppm measured which is above the recommended indoor limit at 1000 ppm. If that room should be design to not exceed 1000 ppm must the air exchange rate increase from 6.3 h-1 to 35.1 h-1.
author Gustafsson, Dennis
author_facet Gustafsson, Dennis
author_sort Gustafsson, Dennis
title Comparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?
title_short Comparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?
title_full Comparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?
title_fullStr Comparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?
title_full_unstemmed Comparing air quality in a training facility : What effects do air balancing have for carbon dioxide reduction?
title_sort comparing air quality in a training facility : what effects do air balancing have for carbon dioxide reduction?
publisher Högskolan i Gävle, Energisystem
publishDate 2017
url http://urn.kb.se/resolve?urn=urn:nbn:se:hig:diva-24049
work_keys_str_mv AT gustafssondennis comparingairqualityinatrainingfacilitywhateffectsdoairbalancinghaveforcarbondioxidereduction
_version_ 1718459790029488128