Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad
This is a technical report about cement stabilization in general and the stabilization process during the construction of a warehouse in Halmstad, Sweden in particular and is written at the section for economy and technology at Halmstad University in collaboration with NCC Anläggning. NCC encountere...
Main Authors: | , |
---|---|
Format: | Others |
Language: | Swedish |
Published: |
Högskolan i Halmstad, Sektionen för ekonomi och teknik (SET)
2008
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-1902 |
id |
ndltd-UPSALLA1-oai-DiVA.org-hh-1902 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-UPSALLA1-oai-DiVA.org-hh-19022013-01-08T13:47:46ZCementstabilisering av Biltemas andra lagerbyggnad i HalmstadsweHadidpour, ManiMattsson, EricHögskolan i Halmstad, Sektionen för ekonomi och teknik (SET)Högskolan i Halmstad, Sektionen för ekonomi och teknik (SET)Högskolan i Halmstad/Sektionen för Ekonomi och Teknik (SET)2008CementstabiliseringstabiliseringThis is a technical report about cement stabilization in general and the stabilization process during the construction of a warehouse in Halmstad, Sweden in particular and is written at the section for economy and technology at Halmstad University in collaboration with NCC Anläggning. NCC encountered variations in compression strength in the stabilized material on the first warehouse that they constructed for the company Biltema. In our report we used the stabilization process of the second warehouse for the same company as a reference to determine what could be done to get a more homogeneous result for future projects. We also looked in to what testing method is the most suitable to determine the result of the stabilization. After interviews with people involved in the process and visits on the work site we have come to the conclusion that the most probable cause to the variations in compression strength is segregation in the ballast material. This segregation can occur in several different occasions in the process such as during the production, transportation and handling on the work site. Other causes for the variation can be improper compaction, overlapping stabilization in some places and different duration of hardening of the samples that are tested. The best way to do in situ test of the stabilized material is to do seismic investigations as those are non-destructive tests in comparison to taking core samples and you can discover any cracks or air bubbles in the material. Student thesisinfo:eu-repo/semantics/bachelorThesistexthttp://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-1902Local 2082/2297application/pdfinfo:eu-repo/semantics/openAccess |
collection |
NDLTD |
language |
Swedish |
format |
Others
|
sources |
NDLTD |
topic |
Cementstabilisering stabilisering |
spellingShingle |
Cementstabilisering stabilisering Hadidpour, Mani Mattsson, Eric Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad |
description |
This is a technical report about cement stabilization in general and the stabilization process during the construction of a warehouse in Halmstad, Sweden in particular and is written at the section for economy and technology at Halmstad University in collaboration with NCC Anläggning. NCC encountered variations in compression strength in the stabilized material on the first warehouse that they constructed for the company Biltema. In our report we used the stabilization process of the second warehouse for the same company as a reference to determine what could be done to get a more homogeneous result for future projects. We also looked in to what testing method is the most suitable to determine the result of the stabilization. After interviews with people involved in the process and visits on the work site we have come to the conclusion that the most probable cause to the variations in compression strength is segregation in the ballast material. This segregation can occur in several different occasions in the process such as during the production, transportation and handling on the work site. Other causes for the variation can be improper compaction, overlapping stabilization in some places and different duration of hardening of the samples that are tested. The best way to do in situ test of the stabilized material is to do seismic investigations as those are non-destructive tests in comparison to taking core samples and you can discover any cracks or air bubbles in the material. |
author |
Hadidpour, Mani Mattsson, Eric |
author_facet |
Hadidpour, Mani Mattsson, Eric |
author_sort |
Hadidpour, Mani |
title |
Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad |
title_short |
Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad |
title_full |
Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad |
title_fullStr |
Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad |
title_full_unstemmed |
Cementstabilisering av Biltemas andra lagerbyggnad i Halmstad |
title_sort |
cementstabilisering av biltemas andra lagerbyggnad i halmstad |
publisher |
Högskolan i Halmstad, Sektionen för ekonomi och teknik (SET) |
publishDate |
2008 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:hh:diva-1902 |
work_keys_str_mv |
AT hadidpourmani cementstabiliseringavbiltemasandralagerbyggnadihalmstad AT mattssoneric cementstabiliseringavbiltemasandralagerbyggnadihalmstad |
_version_ |
1716528901211029504 |