Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction

Escherichia coli O157:H7 is recognized as a major human enteropathogen. Immunotechnology and DNA based methods were developed for quantitative detection of E. coli O157:H7 in ground beef. A direct spectrophotometric immuno-agglutination assay was developed for quantitation of specific Escherichia co...

Full description

Bibliographic Details
Main Author: Sayedahmed, Assem Abolmaaty
Language:ENG
Published: ScholarWorks@UMass Amherst 2006
Subjects:
Online Access:https://scholarworks.umass.edu/dissertations/AAI3215906
id ndltd-UMASS-oai-scholarworks.umass.edu-dissertations-4323
record_format oai_dc
spelling ndltd-UMASS-oai-scholarworks.umass.edu-dissertations-43232020-12-02T14:31:05Z Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction Sayedahmed, Assem Abolmaaty Escherichia coli O157:H7 is recognized as a major human enteropathogen. Immunotechnology and DNA based methods were developed for quantitative detection of E. coli O157:H7 in ground beef. A direct spectrophotometric immuno-agglutination assay was developed for quantitation of specific Escherichia coli O157 IgG. Optimum conditions of the assay consisted of 1 × 108 cells/ml, 40°C, and 0.005M phosphate buffer containing 0.05% NaCl at pH 7.4. The assay was able to quantitate (13 to 104) μg IgG/ml of anti O157 IgG in crude antiserum and was effectively used with different batches of locally produced antisera. A new cell lysis solution designated TZ (2.0% Triton X-100 in 0.1 M Tris-HCl buffer plus 2.5 mg sodium azide/ml, pH 8.0) was developed. TZ lysis solution was found superior to a variety of cell lysing methods (d.H2O, PCR buffer, SDS, Triton X-100, proteinase K, and lysozyme in combination with proteinase K) and released the greatest yield of E. coli O157:H7 DNA targets prior to PCR. Highest amplification of E. coli O157:H7 SLT-1 and SLT-2 DNA sequences were achieved with the aid of TZ lysis solution and pellet paint. Using 0.01 M phosphate buffered saline pH 6.0 with the aid of differential centrifugation resulted in 57% ± 6 recovery of E. coli O157:H7 from seeded ground beef. The optimization of PCR reaction mixture resulted in a minimum detection level of 100 SLT-1 DNA sequence compared to 200 DNA targets before the optimization. Prior to optimization, the minimum limits for the SLT-2 DNA sequence was 150 DNA targets compared to 20 after complete optimization. The complete optimization of PCR reaction mixture contained 1 mM MgCl2, 1.6 μM each of the two primers, (2.5 and 5 units) of Taq polymerase for SLT-1 and SLT-2 respectively, and 0.2 mM of Deoxynucleotide Triphosphates (dNTPs). The methodologies developed thereby resulted in the detection of 100 cells of E. coli O157:H7 with SLT-1 primer and 50 cells with SLT-2 primer per 10 grams of ground beef after 5.5 hours of pre-enrichment in 30 ml of TSB+ at 37°C. 2006-01-01T08:00:00Z text https://scholarworks.umass.edu/dissertations/AAI3215906 Doctoral Dissertations Available from Proquest ENG ScholarWorks@UMass Amherst Food science|Microbiology|Molecular biology
collection NDLTD
language ENG
sources NDLTD
topic Food science|Microbiology|Molecular biology
spellingShingle Food science|Microbiology|Molecular biology
Sayedahmed, Assem Abolmaaty
Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction
description Escherichia coli O157:H7 is recognized as a major human enteropathogen. Immunotechnology and DNA based methods were developed for quantitative detection of E. coli O157:H7 in ground beef. A direct spectrophotometric immuno-agglutination assay was developed for quantitation of specific Escherichia coli O157 IgG. Optimum conditions of the assay consisted of 1 × 108 cells/ml, 40°C, and 0.005M phosphate buffer containing 0.05% NaCl at pH 7.4. The assay was able to quantitate (13 to 104) μg IgG/ml of anti O157 IgG in crude antiserum and was effectively used with different batches of locally produced antisera. A new cell lysis solution designated TZ (2.0% Triton X-100 in 0.1 M Tris-HCl buffer plus 2.5 mg sodium azide/ml, pH 8.0) was developed. TZ lysis solution was found superior to a variety of cell lysing methods (d.H2O, PCR buffer, SDS, Triton X-100, proteinase K, and lysozyme in combination with proteinase K) and released the greatest yield of E. coli O157:H7 DNA targets prior to PCR. Highest amplification of E. coli O157:H7 SLT-1 and SLT-2 DNA sequences were achieved with the aid of TZ lysis solution and pellet paint. Using 0.01 M phosphate buffered saline pH 6.0 with the aid of differential centrifugation resulted in 57% ± 6 recovery of E. coli O157:H7 from seeded ground beef. The optimization of PCR reaction mixture resulted in a minimum detection level of 100 SLT-1 DNA sequence compared to 200 DNA targets before the optimization. Prior to optimization, the minimum limits for the SLT-2 DNA sequence was 150 DNA targets compared to 20 after complete optimization. The complete optimization of PCR reaction mixture contained 1 mM MgCl2, 1.6 μM each of the two primers, (2.5 and 5 units) of Taq polymerase for SLT-1 and SLT-2 respectively, and 0.2 mM of Deoxynucleotide Triphosphates (dNTPs). The methodologies developed thereby resulted in the detection of 100 cells of E. coli O157:H7 with SLT-1 primer and 50 cells with SLT-2 primer per 10 grams of ground beef after 5.5 hours of pre-enrichment in 30 ml of TSB+ at 37°C.
author Sayedahmed, Assem Abolmaaty
author_facet Sayedahmed, Assem Abolmaaty
author_sort Sayedahmed, Assem Abolmaaty
title Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction
title_short Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction
title_full Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction
title_fullStr Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction
title_full_unstemmed Development of methodology for quantitative detection of E. coli O157:H7 in ground beef via immunoassays and the polymerase chain reaction
title_sort development of methodology for quantitative detection of e. coli o157:h7 in ground beef via immunoassays and the polymerase chain reaction
publisher ScholarWorks@UMass Amherst
publishDate 2006
url https://scholarworks.umass.edu/dissertations/AAI3215906
work_keys_str_mv AT sayedahmedassemabolmaaty developmentofmethodologyforquantitativedetectionofecolio157h7ingroundbeefviaimmunoassaysandthepolymerasechainreaction
_version_ 1719364217530744832