4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung

On-board cone-beam computed tomography (CBCT) imaging integrated with medical linear accelerators offers a viable tool for tumor localization just prior to radiation treatment delivery. However, the exact tumor location during treatment is not well-defined due to respiratory motion. This is taken in...

Full description

Bibliographic Details
Main Author: Beaudry, Joel
Language:English
Published: University of British Columbia 2015
Online Access:http://hdl.handle.net/2429/52814
id ndltd-UBC-oai-circle.library.ubc.ca-2429-52814
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-528142018-01-05T17:28:06Z 4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung Beaudry, Joel On-board cone-beam computed tomography (CBCT) imaging integrated with medical linear accelerators offers a viable tool for tumor localization just prior to radiation treatment delivery. However, the exact tumor location during treatment is not well-defined due to respiratory motion. This is taken into account during treatment planning by adding margins to the visible tumor volume defining the high dose region. The respiratory motion used to optimize the treatment plan is not guaranteed to be reproducible on the day of treatment, suggesting that the high dose region may not fully contain the tumor at all points of its trajectory during treatment. In this thesis, to image the tumor at the different portions of the breathing cycle, CBCT projections were binned by the respiratory signal at their time of acquisition. Reconstructing each bin created a 3D image depicting the tumor at one point of its trajectory. Combining the binned reconstructions added in a temporal component, defining a 4D-CBCT. 4D-CBCT reconstructions were performed on 6 stereotactic ablative radiotherapy (SABR) lung cancer patients. Imaging was performed using the Varian TrueBeam (v1.6) and respiratory information was captured with the infra-red camera-based Varian real-time position management (RPM) system. Both analytical and iterative reconstruction algorithms, and image quality metrics were used for a comparative study. Tumor motion was measured by tracking the visible tumor volume centroid from each 4D-CBCT image. The high dose regions defined during treatment planning were compared to the 4D-CBCT tumor volume during its trajectory using an overlap metric to determine if the tumor remained confined to the treatment volume, or not. 4D-CBCTs were found to be well reconstructed using iterative methods. When viewed sequentially the 4D-CBCT images visibly show tumor motion following a sinusoidal-like behavior. Examination of the tumor motion and overlap metric verify that the margins currently used to define the high dose region fully encompass the tumor during all times of its trajectory, i.e 100% overlap within error. The results indicate the current margins used for SABR patients at the British Columbia Cancer Agency are sufficient in providing adequate tumor coverage when accounting for tumor motion and setup uncertainties. Science, Faculty of Physics and Astronomy, Department of Graduate 2015-04-16T17:24:10Z 2015-04-16T17:24:10Z 2015 2015-05 Text Thesis/Dissertation http://hdl.handle.net/2429/52814 eng Attribution-NonCommercial-NoDerivs 2.5 Canada http://creativecommons.org/licenses/by-nc-nd/2.5/ca/ University of British Columbia
collection NDLTD
language English
sources NDLTD
description On-board cone-beam computed tomography (CBCT) imaging integrated with medical linear accelerators offers a viable tool for tumor localization just prior to radiation treatment delivery. However, the exact tumor location during treatment is not well-defined due to respiratory motion. This is taken into account during treatment planning by adding margins to the visible tumor volume defining the high dose region. The respiratory motion used to optimize the treatment plan is not guaranteed to be reproducible on the day of treatment, suggesting that the high dose region may not fully contain the tumor at all points of its trajectory during treatment. In this thesis, to image the tumor at the different portions of the breathing cycle, CBCT projections were binned by the respiratory signal at their time of acquisition. Reconstructing each bin created a 3D image depicting the tumor at one point of its trajectory. Combining the binned reconstructions added in a temporal component, defining a 4D-CBCT. 4D-CBCT reconstructions were performed on 6 stereotactic ablative radiotherapy (SABR) lung cancer patients. Imaging was performed using the Varian TrueBeam (v1.6) and respiratory information was captured with the infra-red camera-based Varian real-time position management (RPM) system. Both analytical and iterative reconstruction algorithms, and image quality metrics were used for a comparative study. Tumor motion was measured by tracking the visible tumor volume centroid from each 4D-CBCT image. The high dose regions defined during treatment planning were compared to the 4D-CBCT tumor volume during its trajectory using an overlap metric to determine if the tumor remained confined to the treatment volume, or not. 4D-CBCTs were found to be well reconstructed using iterative methods. When viewed sequentially the 4D-CBCT images visibly show tumor motion following a sinusoidal-like behavior. Examination of the tumor motion and overlap metric verify that the margins currently used to define the high dose region fully encompass the tumor during all times of its trajectory, i.e 100% overlap within error. The results indicate the current margins used for SABR patients at the British Columbia Cancer Agency are sufficient in providing adequate tumor coverage when accounting for tumor motion and setup uncertainties. === Science, Faculty of === Physics and Astronomy, Department of === Graduate
author Beaudry, Joel
spellingShingle Beaudry, Joel
4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
author_facet Beaudry, Joel
author_sort Beaudry, Joel
title 4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
title_short 4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
title_full 4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
title_fullStr 4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
title_full_unstemmed 4D cone-beam CT image reconstruction of Varian TrueBeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
title_sort 4d cone-beam ct image reconstruction of varian truebeam v1.6 projection images for clinical quality assurance of stereotactic ablative radiotherapy to the lung
publisher University of British Columbia
publishDate 2015
url http://hdl.handle.net/2429/52814
work_keys_str_mv AT beaudryjoel 4dconebeamctimagereconstructionofvariantruebeamv16projectionimagesforclinicalqualityassuranceofstereotacticablativeradiotherapytothelung
_version_ 1718584703972278272