Reduction of current/torque ripple in low power grid-tie PMSG wind turbines

Small-scale Wind Energy Conversion Systems (WECS) are becoming an attractive option for distributed and renewable energy generation. In order to be affordable, WECS must have low capital and maintenance costs. This leads to the increasing penetration of Permanent Magnet Synchronous Generators (PMSG)...

Full description

Bibliographic Details
Main Author: Ksiazek, Peter F.
Language:English
Published: University of British Columbia 2014
Online Access:http://hdl.handle.net/2429/50298
id ndltd-UBC-oai-circle.library.ubc.ca-2429-50298
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-502982018-01-05T17:27:40Z Reduction of current/torque ripple in low power grid-tie PMSG wind turbines Ksiazek, Peter F. Small-scale Wind Energy Conversion Systems (WECS) are becoming an attractive option for distributed and renewable energy generation. In order to be affordable, WECS must have low capital and maintenance costs. This leads to the increasing penetration of Permanent Magnet Synchronous Generators (PMSG) operating at variable frequency with connections to the power grid through a rectifier, and grid-tie inverter. Because PMSGs lack brushes and can be directly coupled to wind turbines, the capital and maintenance costs are greatly reduced. A direct connection to the grid further reduces system costs by removing the requirement of large battery banks. The loading produced by grid-tie inverters on the DC bus is different than more typical constant-current or constant-power loads. They are characterized by large input ripple currents at twice the inverter's grid frequency. These ripple currents are reflected through the DC bus into the PMSG causing increased heating in the stator, and ripple torques which lead to premature bearing failure and increased maintenance costs. To mitigate this problem, manufacturers typically add large amounts of capacitance on the DC bus to partially absorb these ripples at the expense of system size, cost, and reliability. In this work, the effects of the grid-tie inverter load are explored using system behavioural models which provide insight into the low frequency behaviour of the PMSG, rectifier, DC bus, and inverter. The swinging bus concept is presented and analysed in the time and frequency domains. A control philosophy is developed which allows the DC bus to swing, thus removing the effects of the grid-tie inverter on the PMSG while keeping the DC bus capacitor small. A solution consisting of a Moving Average Filter (MAF) is presented as an integral part of the control strategy. Full simulations of a complete system are developed and investigated to verify the ripple torque reduction technique. Finally, a prototype is developed and experimental results are presented for a 2.5kW PMSG turbine generator. The simulation and experimental results are compared to a traditional controller showing tangible improvements in ripple current and torque in the PMSG, while improving the dynamic response of the system. Applied Science, Faculty of Electrical and Computer Engineering, Department of Graduate 2014-09-03T14:45:29Z 2014-09-03T14:45:29Z 2014 2014-11 Text Thesis/Dissertation http://hdl.handle.net/2429/50298 eng Attribution-NonCommercial-NoDerivs 2.5 Canada http://creativecommons.org/licenses/by-nc-nd/2.5/ca/ University of British Columbia
collection NDLTD
language English
sources NDLTD
description Small-scale Wind Energy Conversion Systems (WECS) are becoming an attractive option for distributed and renewable energy generation. In order to be affordable, WECS must have low capital and maintenance costs. This leads to the increasing penetration of Permanent Magnet Synchronous Generators (PMSG) operating at variable frequency with connections to the power grid through a rectifier, and grid-tie inverter. Because PMSGs lack brushes and can be directly coupled to wind turbines, the capital and maintenance costs are greatly reduced. A direct connection to the grid further reduces system costs by removing the requirement of large battery banks. The loading produced by grid-tie inverters on the DC bus is different than more typical constant-current or constant-power loads. They are characterized by large input ripple currents at twice the inverter's grid frequency. These ripple currents are reflected through the DC bus into the PMSG causing increased heating in the stator, and ripple torques which lead to premature bearing failure and increased maintenance costs. To mitigate this problem, manufacturers typically add large amounts of capacitance on the DC bus to partially absorb these ripples at the expense of system size, cost, and reliability. In this work, the effects of the grid-tie inverter load are explored using system behavioural models which provide insight into the low frequency behaviour of the PMSG, rectifier, DC bus, and inverter. The swinging bus concept is presented and analysed in the time and frequency domains. A control philosophy is developed which allows the DC bus to swing, thus removing the effects of the grid-tie inverter on the PMSG while keeping the DC bus capacitor small. A solution consisting of a Moving Average Filter (MAF) is presented as an integral part of the control strategy. Full simulations of a complete system are developed and investigated to verify the ripple torque reduction technique. Finally, a prototype is developed and experimental results are presented for a 2.5kW PMSG turbine generator. The simulation and experimental results are compared to a traditional controller showing tangible improvements in ripple current and torque in the PMSG, while improving the dynamic response of the system. === Applied Science, Faculty of === Electrical and Computer Engineering, Department of === Graduate
author Ksiazek, Peter F.
spellingShingle Ksiazek, Peter F.
Reduction of current/torque ripple in low power grid-tie PMSG wind turbines
author_facet Ksiazek, Peter F.
author_sort Ksiazek, Peter F.
title Reduction of current/torque ripple in low power grid-tie PMSG wind turbines
title_short Reduction of current/torque ripple in low power grid-tie PMSG wind turbines
title_full Reduction of current/torque ripple in low power grid-tie PMSG wind turbines
title_fullStr Reduction of current/torque ripple in low power grid-tie PMSG wind turbines
title_full_unstemmed Reduction of current/torque ripple in low power grid-tie PMSG wind turbines
title_sort reduction of current/torque ripple in low power grid-tie pmsg wind turbines
publisher University of British Columbia
publishDate 2014
url http://hdl.handle.net/2429/50298
work_keys_str_mv AT ksiazekpeterf reductionofcurrenttorquerippleinlowpowergridtiepmsgwindturbines
_version_ 1718584432390045696