Reconsideration of the diaphragm cell method of measuring diffusion coefficients.

The diaphragm cell technique for measurement of diffusion coefficients has been subjected to detailed analysis with the particular view to obtaining measurements on the various solutions involved in solvent extraction of uranium and its compounds. Consideration of types of cells used previously has...

Full description

Bibliographic Details
Main Author: Dullien, Francis Andrew Leslie
Language:English
Published: University of British Columbia 2012
Subjects:
Online Access:http://hdl.handle.net/2429/40037
id ndltd-UBC-oai-circle.library.ubc.ca-2429-40037
record_format oai_dc
spelling ndltd-UBC-oai-circle.library.ubc.ca-2429-400372018-01-05T17:49:52Z Reconsideration of the diaphragm cell method of measuring diffusion coefficients. Dullien, Francis Andrew Leslie Diffusion The diaphragm cell technique for measurement of diffusion coefficients has been subjected to detailed analysis with the particular view to obtaining measurements on the various solutions involved in solvent extraction of uranium and its compounds. Consideration of types of cells used previously has led to an improved diaphragm cell design. An apparatus accommodating and magnetically stirring six cells simultaneously was designed and constructed. The result of errors of analysis of solutions on the diffusion coefficients has been determined as a function of the experimental conditions. The effect that volume changes occurring in real solutions during diffusion have on the value of the diffusion coefficient D, as computed by the standard logarithmic formula, was considered. Computations carried out in a first approximation showed that although the error committed by the neglect of volume changes is appreciably larger than estimated by previous workers it is not large enough to account for the full amount of some discrepancies reported in the literature. A numerical procedure is given for pursuing the analysis in a second and a third approximation involving decreasing dependence on the simplifying assumptions always made in previous calculations using this technique. This procedure can be programmed on an electronic computer. It is proposed that in situ concentration determinations at the beginning and end of a diffusion experiment be used based on comparison with an outside standard. Combined with the numerical method suggested this will allow considerable reduction in the concentration difference between the two solutions in the cell without significant loss in accuracy or increase in experimental time, and also make the measured diffusion coefficient a more "true" value. Applied Science, Faculty of Chemical and Biological Engineering, Department of Graduate 2012-01-12T20:31:50Z 2012-01-12T20:31:50Z 1958 Text Thesis/Dissertation http://hdl.handle.net/2429/40037 eng For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. University of British Columbia
collection NDLTD
language English
sources NDLTD
topic Diffusion
spellingShingle Diffusion
Dullien, Francis Andrew Leslie
Reconsideration of the diaphragm cell method of measuring diffusion coefficients.
description The diaphragm cell technique for measurement of diffusion coefficients has been subjected to detailed analysis with the particular view to obtaining measurements on the various solutions involved in solvent extraction of uranium and its compounds. Consideration of types of cells used previously has led to an improved diaphragm cell design. An apparatus accommodating and magnetically stirring six cells simultaneously was designed and constructed. The result of errors of analysis of solutions on the diffusion coefficients has been determined as a function of the experimental conditions. The effect that volume changes occurring in real solutions during diffusion have on the value of the diffusion coefficient D, as computed by the standard logarithmic formula, was considered. Computations carried out in a first approximation showed that although the error committed by the neglect of volume changes is appreciably larger than estimated by previous workers it is not large enough to account for the full amount of some discrepancies reported in the literature. A numerical procedure is given for pursuing the analysis in a second and a third approximation involving decreasing dependence on the simplifying assumptions always made in previous calculations using this technique. This procedure can be programmed on an electronic computer. It is proposed that in situ concentration determinations at the beginning and end of a diffusion experiment be used based on comparison with an outside standard. Combined with the numerical method suggested this will allow considerable reduction in the concentration difference between the two solutions in the cell without significant loss in accuracy or increase in experimental time, and also make the measured diffusion coefficient a more "true" value. === Applied Science, Faculty of === Chemical and Biological Engineering, Department of === Graduate
author Dullien, Francis Andrew Leslie
author_facet Dullien, Francis Andrew Leslie
author_sort Dullien, Francis Andrew Leslie
title Reconsideration of the diaphragm cell method of measuring diffusion coefficients.
title_short Reconsideration of the diaphragm cell method of measuring diffusion coefficients.
title_full Reconsideration of the diaphragm cell method of measuring diffusion coefficients.
title_fullStr Reconsideration of the diaphragm cell method of measuring diffusion coefficients.
title_full_unstemmed Reconsideration of the diaphragm cell method of measuring diffusion coefficients.
title_sort reconsideration of the diaphragm cell method of measuring diffusion coefficients.
publisher University of British Columbia
publishDate 2012
url http://hdl.handle.net/2429/40037
work_keys_str_mv AT dullienfrancisandrewleslie reconsiderationofthediaphragmcellmethodofmeasuringdiffusioncoefficients
_version_ 1718596540657827840